Download COMPACTplus-m - Leuze electronic
Transcript
Warning! The current path via the relay contacts of the AOPD must be compulsorily protected to prevent the contacts welding in the event of an overcurrent. The fuse sizes depend on the load. They are described in Table 12.1-7. ENGLISH Warning! For higher switching voltages of up to 250 V AC, the load circuit must be separated from the voltage supply and the status signals. In this case two cables must be routed through the cable screw; the second lead-in opening has already been prepared and must now only be pushed through. DEUTSCH Electrical connection FRANÇAIS a a = Just push opening through when a separate connection cable for the load circuit is to be connected. Cable screw M25x1.5, application prepared for connecting 2 cables NEDERLANDS ESPAÑOL ITALIANO TNT 35/7-24V Fig. 7.6-1: Leuze electronic COMPACTplus-m 69