Download Controller 218M for milling

Transcript
GSK218M CNC System
Connection and PLC Manual
ZRNX When a instruction specifying the movement(except for G28) is issued in
automatic operation(MEM, RMT or MDI) before referencing is completed.
1: An alarm is generated (P/S alarm 224).
0: No alarm is generated.
Note:
0007
When the parameter is changed, the power supply must be turned off before operation
and then is turned on again.
#7
#6
#5
#4
#3
ZMI5
ZMI4
ZMIz
ZMIy
ZMIX
#2
#1
#0
#2
#1
#0
[Data Classification] bit-axis
ZMI
Direction of reference point return
0:positive direction
1:negative direction
#7
#6
#5
#4
#3
ZCL
0009
[Data Classification] Bit
ZCL Local coordinate system after the manual reference point return is
executed.
0:The local coordinate system is not canceled.
1:The local coordinate system is canceled.
Note: After setting the parameter, the power supply must be turned off, and the parameter will take
effect after restart.
62