Download ACH550 Consolidated Manual 2011
Transcript
1-330 ACH550-UH User’s Manual Applicable standards Drive compliance with the following standards is identified by the standards “marks” on the type code label. Mark Applicable Standards EN 50178 (1997) Electronic equipment for use in power installations EN 60204-1 (1997 + corrigendum Sep. 1998) Safety of machinery. Electrical equipment of machines. Part 1: General requirements. Provisions for compliance: The final assembler of the machine is responsible for installing: • An emergency-stop device • A supply disconnecting device EN 60529 (1991 + corrigendum May 1993 + amendment A1:2000) Degrees of protection provided by enclosures (IP code) EN 61800-3 (1996) + Amendment A11 (2000) EMC product standard including specific test methods EN 61800-3 (1996) + Amendment A11 (2000) EMC product standard including specific test methods UL 508C and C22.2 No. 14 UL Standard for Safety, Power Conversion Equipment, second edition and CSA Standard for Industrial Control Equipment C22.2 No. 14 CSA Standard for Industrial Control Equipment Compliance is valid with the following provisions: • The motor and control cables are chosen as specified in this manual. • The installation rules of this manual are followed. UL markings When a UL mark is attached to the ACH550 AC drive, it verifies that the drive follows the provisions of UL 508C. When a CSA mark is attached to the ACH550 AC drive, it verifies that the drive follows the provisions of C22.2 No. 14. The ACH550 is UL and CSA listed to 100 KAIC without use of input fuses or circuit breaker. For end-users convenience, the section Fuses provides fuse recommendations. Branch circuit protection must to be provided per local code. Note: UL508A manufactures are not required to use the fuse recommendations for the purpose of UL Listing a panel with an ACH550 AFD. The ACH550 has an electronic motor protection feature that complies with the requirements of UL 508C and CSA C22.2 No. 14. When this feature is selected and properly adjusted, additional overload protection is not required unless more than one motor is connected to the drive or unless additional protection is required by applicable safety regulations. See parameters 3005 (MOT THERM PROT) and 3006 (MOT THERM TIME). Technical data
Related documents
ACH550-UH User`s Manual
ABB RDNA-01 User`s manual
User`s Manual - Culinaire Systems
1-130 ACH550-UH User`s Manual Parameters User
User`s Manual - Flow Tech, Inc.
ACS550-01/U1 Drive User's Manual
ABB ACH550 User`s manual
ACS550-01/U1 Drive User`s Manual
ACS310 User`s Manual - HSL Automation Home Page
Rion NL-27 User Manual
User`s manual ACB530
User`s Manual - HSL Automation Home Page