Download 1 HEADING 1
Transcript
37 44 SIREN AND SYSTEM SUPERVISION Segment 1 (Circle Numbers To Program) 1 Reserved 2 3 4 5 6 7 Reserved Siren blast at arming (pulse) Siren blast at exit delay expiration (pulse) Siren blast at closing kissoff (pulse) Siren sounds during a cross zone verification time Siren sounds for a tamper 8 Siren blast once for keyswitch arming, twice for disarming Segment 2 (Circle Numbers To Program) Convert siren driver to voltage out Siren sounds for expander trouble Zones to always restore Dynamic battery test performed upon arming Battery missing test performed every 12 seconds 1 2 3 4 5 6 7 8 1 2 3 38 45 Manual bell test performed during [*]-[4]-[4]test function Manual communicator test performed during [*]-[4]-[4] test function Box tamper enabled Segment 3 (Circle Numbers To Program) Box Tamper report enabled AC Fail report enabled Low Battery report enabled 4 5 6 7 8 Auxiliary power overcurrent report enabled Siren supervision report enabled Reserved A+B Alarm (for Norway and Sweden only) Expander trouble report enabled Segment 4 (Circle Numbers To Program) 1 2 3 4 5 6 7 Failure To Communicate report enabled Log Full report enabled Autotest report enabled Start and End Programming report enabled End Download report enabled Sensor Low Battery report enabled Sensor Missing report enabled 8 1 2 3 4 5 Autotest report enabled ONLY when system is armed Segment 5 (Circle Numbers To Program) Lost Clock service LED enable Reserved Disable six on-board zones Enable two trips on the same cross-zone to activate the alarm Disable bypass reports for force armed zones 6 7 8 Silent exit Reserved Automatic switch summer/wintertime and vice versa SWINGER COUNTDOWN COUNT NX-4 Installation manual 0 Page 69 Date 13/03/04