Download CombiMagBloc

Transcript
CombiMagBloc
7.4
Dismantling the pump
In most cases the entire pump is dismantled, to inspect respectively repair it in the work
shop, under clean conditions.
1 Ensure the shut-off valves are closed and the pump is drained.
2 Open the junction box and disconnect the wiring.
3 In case a foot/flange motor (IM2001 - B3/B5) is mounted: remove the fixation bolts
of the motor feet.
4 Disassemble the appropriate bolts and nuts and disconnect the discharge and
suction flanges from the piping system.
5 Remove the fixation bolts of the pump feet.
6 Remove the pump, using a hoisting device, and place it on a pallet for further internal
transport.
Place a warning sign close to the pump on the pallet, warning against the
hazards of the magnetic field!
Ꮪ
Place a warning sign close to the pump on the pallet warning against the
harmful effects of the magnetic field!
7.5
References
If no specific figure number is stated, all item numbers mentioned in the instructions
below, refer to the parts lists and sectional drawings in chapter 9.
7.6
Disassembly of the outer rotor
1 Place the pump vertically on a work bench, resting on the suction flange.
2 Disassemble bolts (0950) and nuts (0900).
3 Remove the fan protective cover of the electric motor and screw a lifting lug into the
threaded hole in the shaft end.
4 Fix a hook or a lifting belt to the lifting lug and pull off the motor and the outer rotor
from the pump casing, using a hoisting device. Initial resistance is experienced due to
the strong magnetic forces.
Be prepared for a sudden jolt of the load!
CMB/EN (1301) 3.4
Disassembly and assembly
29