3 Use the Right cursor key to scroll through the PLC parameters until the Configured Constant Sweep Setting (CFG CONS TM) parameter is displayed. To set the sweep time, enter a value between 5 and 200 milliseconds, and press the ENT key. The default setting is 100 milliseconds. I/O Scan in Stop Mode Parameter By default, the PLC will not scan I/O in stop mode. Enabling this parameter, however, allows you to debug and test input and output wiring without a control program installed. Use the Right cursor key to scroll through the PLC parameters until the I/O scan in stop mode (STOP MD) parameter is displayed. Then, use the –/+ key to toggle the selection between NO I/O and DO I/O. Dual Use Checking Parameter The dual use checking parameter allows you to select whether or not %M and %Q references should be restricted to single use as outputs within the user logic program. When enabled, the system will not allow you to assign the same reference to two different coils. Note This feature is not editable in a Model 351 CPU, since this parameter applies to the user program, not the configuration. Use the Right cursor key to scroll through the PLC parameters until the dual use checking (COIL US) parameter is displayed. Then, use the –/+ key to toggle between SINGLE, WRN MUL, and MULT. By default, WRN MUL is enabled. When toggling from MULT to SINGLE or WRN MUL, the program is checked for multiple coil usage. If multiple coils are detected, you can go to program mode and find the multiple coil usage with the SRCH, #, –1 key sequence. When going to SINGLE, the transition is not allowed; when going to WRN MUL, the transition is allowed. SINGLE check prevents using the same %M or %Q coil reference in two or more locations in the program. WRN MUL allows multiple coil uses of the same %M or %Q reference, but provides a warning screen to the user that this is being done, and MULT allows multiple coil usage without a warning. Note When an instruction is added and the coil use warning message is displayed, the warning message should be verified with the search function. It is possible that the use warning message is displayed even though the coil is used only once in the program. The PLC parameters described on the following pages are controlled by the Hand-Held Programmer, but do not affect its operation. They are used for communications through the power supply port with devices other than the HHP. 3-8 Hand-Held Programmer for Series 90-30/20/Micro Programmable Controllers User’s Manual – February 1996 GFK-0402G
Related documents
Berkeley Pascal PX Implementation Notes Version 2.0 − January
Galaxy classic series 8/18/60/128
Monitor Audio Vector User manual
User`s Manual UT100 Series Communication Functions
KNX Reference Design Evaluation Board User`s Manual
FMC32 User`s Manual
IPI, IC693 CPU Firmware for Full Production, GFK
GSC400 Series
1 DATECS
Series 90-30 Ethernet NIU User`s Manual, GFK-2296
Operator Interface Terminal User`s Manual, GFK-0505
GE Fanuc | Series 90-30 | IC693CMM302