Download Tyco Fire Protection Products - Fire Detection

Transcript
Fire Detection Product Catalogue
Conventional (Non-Addressable) Manual Call Points
SU0631 Manual Call Point
The SU0631 Manual Call Point is supplied with
one normally open and one normally closed
contact. Selecting either the “Normally Open” or
“Normally Closed” contact is easily achieved by
simply connecting the terminal block to the required
connection in the back of the MCP. Single pole
changeover switching can be achieved with the use
of two terminal blocks. The call point is operated
when the frangible glass element is snapped,
releasing the MCP’s micro switch, which signals an
alarm to the fire panel. The Call Point and Backbox
are ordered separately. Unless stated the Tyco indoor
manual call points are supplied as flush mount
units. The Tyco range are approved for use with the
standard backbox if surface mounting is required.
Specifications
Max. Operating Voltage
Max. Switch Current
Cable Termination
Relative Humidity
Ambient Temperature
Dimensions (HWD)
Weight
Ingress Protection
30Vdc
2A
0.5 to 2.5 mm2
0 to 95% (non/cond)
-10°C to +55°C
93x89x60mm
110g (flush)
IP24D
ActivFire Listed
Part Numbers
afp-1385
SU0631
SU0632
SC070
515.001.025
Manual Call Point
Red Backbox
Spare Test Keys (pkt10)
Spare Glass (pkt 5)
SU0634 IP67 Waterproof Call Point
This surface mounting Manual Call Point has
an Ingress Protection rating of IP67, making it
suitable for wet area applications. The callpoint is
operated by simply pressing on the centre of the
frangible element until it snaps, which releases a
microswitch, signaling an alarm at the CIE. A plastic
coated frangible element ensures safe and reliable
operation, and does not produce dangerous glass
shards. The SU0634 is supplied with one normally
- open and one normally - closed contact. Selecting
either configuration is achieved by locating the
terminal block on the appropriate connection. Single
pole change-over switching can be achieved using
two terminal blocks.
Specifications
Operating Voltage
30Vdc (max.)
Switch Current
2A @ 30Vdc (max.)
Cable Termination
0.5mm2 to 2.5mm2
Dimensions (HWD)
93x98x76 mm
Weight270g
Ambient Temperature
-30°C to +70°C
Relative Humidity
up to 95% (non-cond.)
Ingress Protection
IP67
Not ActivFire listed by Tyco
Part Numbers
SU0634
IP67 Manual Call Point
515.001.025
Spare Glass (pk 5)
SC070
Spare Test Keys (pkt10)
Manual Call Point Accessories
Specifications
Dimensions (mm)
75W x 40H typical
Part Numbers
SU0603
Spare glass Tyco logo (Pkt 10)
white text on black background
SU0605
Spare glass Wormald logo (Pkt 10)
white text on black background
SU0609
Spare glass Black pictogram on
white background (Pkt 10)
515.001.025 Spare glass no logo (Pkt 5)
clear text on white background
515.001.127 Flexible plastic element
Part Number
SC070
Page 10
Packet of ten Test
keys for Tyco MCPs
Specifications
Ambient Temperature
Dimensions (HWD)
-10°C to +55°C
86 sq x 32 mm
Part Numbers
SU0632
Part Number
515.001.043 Thispolycarbonate
breakglass keybox is
available to protect
emergency keys
Part Number
SR3T-P
Red surface mounting back box (for
indoor callpoints) with terminals fitted.
Red Backbox
Part Number
SU0615
Transparent hinged
cover to suit all
SUxxx call points
(MCP not included).
Material LEXAN241
polycarbonate.
www.tycofireprotectionproducts–anz.com
Part Number
515.001.026 Black call point
bezel for Tyco
CP200/500/900