Download Tyco Fire Protection Products - Fire Detection
Transcript
Fire Detection Product Catalogue Conventional (Non-Addressable) Manual Call Points SU0631 Manual Call Point The SU0631 Manual Call Point is supplied with one normally open and one normally closed contact. Selecting either the “Normally Open” or “Normally Closed” contact is easily achieved by simply connecting the terminal block to the required connection in the back of the MCP. Single pole changeover switching can be achieved with the use of two terminal blocks. The call point is operated when the frangible glass element is snapped, releasing the MCP’s micro switch, which signals an alarm to the fire panel. The Call Point and Backbox are ordered separately. Unless stated the Tyco indoor manual call points are supplied as flush mount units. The Tyco range are approved for use with the standard backbox if surface mounting is required. Specifications Max. Operating Voltage Max. Switch Current Cable Termination Relative Humidity Ambient Temperature Dimensions (HWD) Weight Ingress Protection 30Vdc 2A 0.5 to 2.5 mm2 0 to 95% (non/cond) -10°C to +55°C 93x89x60mm 110g (flush) IP24D ActivFire Listed Part Numbers afp-1385 SU0631 SU0632 SC070 515.001.025 Manual Call Point Red Backbox Spare Test Keys (pkt10) Spare Glass (pkt 5) SU0634 IP67 Waterproof Call Point This surface mounting Manual Call Point has an Ingress Protection rating of IP67, making it suitable for wet area applications. The callpoint is operated by simply pressing on the centre of the frangible element until it snaps, which releases a microswitch, signaling an alarm at the CIE. A plastic coated frangible element ensures safe and reliable operation, and does not produce dangerous glass shards. The SU0634 is supplied with one normally - open and one normally - closed contact. Selecting either configuration is achieved by locating the terminal block on the appropriate connection. Single pole change-over switching can be achieved using two terminal blocks. Specifications Operating Voltage 30Vdc (max.) Switch Current 2A @ 30Vdc (max.) Cable Termination 0.5mm2 to 2.5mm2 Dimensions (HWD) 93x98x76 mm Weight270g Ambient Temperature -30°C to +70°C Relative Humidity up to 95% (non-cond.) Ingress Protection IP67 Not ActivFire listed by Tyco Part Numbers SU0634 IP67 Manual Call Point 515.001.025 Spare Glass (pk 5) SC070 Spare Test Keys (pkt10) Manual Call Point Accessories Specifications Dimensions (mm) 75W x 40H typical Part Numbers SU0603 Spare glass Tyco logo (Pkt 10) white text on black background SU0605 Spare glass Wormald logo (Pkt 10) white text on black background SU0609 Spare glass Black pictogram on white background (Pkt 10) 515.001.025 Spare glass no logo (Pkt 5) clear text on white background 515.001.127 Flexible plastic element Part Number SC070 Page 10 Packet of ten Test keys for Tyco MCPs Specifications Ambient Temperature Dimensions (HWD) -10°C to +55°C 86 sq x 32 mm Part Numbers SU0632 Part Number 515.001.043 Thispolycarbonate breakglass keybox is available to protect emergency keys Part Number SR3T-P Red surface mounting back box (for indoor callpoints) with terminals fitted. Red Backbox Part Number SU0615 Transparent hinged cover to suit all SUxxx call points (MCP not included). Material LEXAN241 polycarbonate. www.tycofireprotectionproducts–anz.com Part Number 515.001.026 Black call point bezel for Tyco CP200/500/900