Download TekPatrol Administrators Guide
Transcript
TekPatrol Administrator’s Guide V040813 Network Config The “network config” command allows for editing the network configuration settings. These settings begin with the unit IP address, each octet is displayed allowing a new value to be entered, or just accepting the current value by depressing the enter key. An entered IP value of 0.0.0.0 defines DHCP mode. Once the IP address is entered, Gateway and Subnet masks may be entered or modified in the same manner. Values entered are not permanently stored until the “Save and Exit” command is executed. Factory Defaults The “Factory Defaults” command resets all setup values to their initial defaults. DHCP mode = enabled SMTP port = 25 TEKPATROL port = 5070 TEKCONTROL port = 5072 PASSCODE = 6373 Serial Port 1 = 9600,N,1 SerialPort2 = 9600,N,1 Save and Exit The “Save and Exit” command forces a save of data to the TekMonitor non-volatile storage area. Once saved, the unit is reset, disconnecting the USB channel. The TekDebug program will have to be restarted in order to reestablish connection. Reset The “Reset” command forces a reset of the TekMonitor resulting in a disconnection of the USB channel. The TekDebug program will have to be restarted in order to reestablish connection. Quit The “Quit” command disconnects the USB channel, and the TekDebug program will have to be restarted in order to reestablish connection. 51 TEKVOX, Inc. – 210.348.6565 – www.TEKVOX.com San Antonio, TX 78216