Download PK2100 - Digi International
Transcript
PK2100 Inputs and Outputs The PK2100 provides these types of inputs/outputs: Universal analog inputs. Protected digital inputs. High-gain differential analog input. SPDT relays. High-current driver outputs capable of driving inductive loads such as solenoids and relays. Analog outputs. 2 × 20-charcter LCD screen (backlighted display available) and 2 × 6 keypad. Serial communication channels: PLCBus port, RS-232 port, and RS-232 or RS-485/RS-422 port. Figure 3-1 shows the signal names of the PK2100s screw connectors. The chapter describes the various interfaces and presents some typical applications. There are 50 screw terminals used for input, output, and power connections. In addition, there are two connectors on the sides of the unit: a modular phone jack connector for the RS-232 port, and a 26-pin connector for the PLCBus expansion port. +10-V ref +5 V GND U1 U2 U3 U4 U5 U6 GND D1 D2 D3 D4 D5 / C1A D6 / C1B D7/ C2A GND GND Tx RS-485/ Tx+ RS-422 Rx Rx+ C2B+ C2B Digital Inputs Universal Inputs DC in K GND O1 O2 O3 O4 O5 O6 O7 O8 O9 O10 GND A/D A/D+ DAC UEXP NC1 COM1 NO1 NC2 COM2 NO2 GND Digital Outputs PLCBus Relay 1 Relay 2 RS-232 Figure 3-1. PK2100 Pin Layout 3-2 s I/O Configurations PK2100