Download User Manual - EndRun Technologies
Transcript
APPENDIX I ALARM RELAY OUTPUTS Quantity: 0 or 3. Type: Form C. Rating: 750 mA @ 42VAC/60VDC. NC Contact: Closed for alarm-active condition. NO Contact: Closed for alarm-inactive condition. Minor Alarm: Active at minor clock faults. Major Alarm: Active at major clock fault (Blue Alarm). Critical Alarm: Active at clock operational fault (Red Alarm). Connector: DB9 Female. Pinout: 1 Minor NC 2 Minor NO 3 Major COM 4 Critical NC 5 Critical NO 6 Minor COM 7 Major NC 8 Major NO 9 Critical COM CE/FCC Compliance: RTTE Directive 99/5/EC Low Voltage Directive 73/23/EC EMC Directive 89/336/EC With Amendment 93/68/EC Supplementary Compliance Data: Safety: EMC: 108 EN 60950;1992, A1,A2: 1993, A3: 1995, A4: 1997, A11:1998 EN 55024:1998 w/ A1:2000 and A2:2003, EN61000-3-2:2000, EN61000-3-3:1995 w/ A1:2001, EN55022:1998 Class A, VCCI (April 2004) Class A, FCC Part 15 Subpart B Class A, ICES-003 Class A Ty c h o G P S U s e r M a n u a l