Download E-COMBI EVO E-SYSTEM EVO

Transcript
Description
value
default setting
Parameter
sub-menu
menu
settings - adjustment - problem identification menus
2
2
4
4
BOILER PARAMETER - PART 2
3 Post-ventilation after heating request
2
4
4
2
2
2
4
4
4
5
6
7
2
2
4
4
8
9
2
2
5
5
DOMESTIC HOT WATER PARAMETER
0 COMFORT function
E-COMBI EVO
2
5
1
2
5
2
2
5
3
2
5
4
2
5
5
Comfort Anti-cycling Time
from 0 to 120 (minutes)
0
E-COMBI EVO
Hot water flow delay
from 5 to 200 (0.5 to 20 seconds)
5 Anti “water hammering”
E-COMBI EVO
Extinction of the burner in D. H. W.
0 = anti-scale (stop at > 67°C)
0
E-COMBI EVO
1 = + 4°C /setting
Post-circulation and post-ventilation after a 0 = OFF
0
domestic hot water draw-off
1 = ON
OFF = 3 minutes post-circulation and post-ventilation after domestic hot water draw-off
if the boiler temperature measured requires it.
ON = always on for 3 minutes post-circulation and post-ventilation after domestic hot
water draw-off.
Domestic hot water timer
from 0 to 30 (minutes)
0
2
5
7
<Not Available>
2
5
8
<Not Available>
2
2
6
6
BOILER MANUAL SETTINGS
0 Manual mode activation
2
6
1
Boiler pump control
2
6
2
Fan control
2
6
3
3 way valve control
2
6
4
<Not Available>
42
0 = OFF
0
1 = ON
Time delay after heating temperature
from 0 to 60
16 Activated only with thermostat On/
increase
(minutes)
Off and heating control activated
This parameter allows the time delay to be set before automatic increase of the flow (parameter 421 - 521 - 621 = 01)
temperature calculated in increments of 4°C (max 12°C). If this parameter retains the value
00, this function is not active.
<Not Available>
<Not Available>
Device indicator for heating circuit pressure 0 = temperature sensor only
1 = pressure switch at minimum
2 = pressure sensor
<Not Available>
External temperatura correction
from -3 to +3 (°C)
1
RESERVED FOR TECHNICAL
ASSISTANCE
Only if the PCB is changed
0
Only active with external sensor
connected
0 = deactivated
0
1 = timed
2 = always on
The appliance allows the hot water heating comfort to be increased via the “COMFORT”
function.
This function keeps the secondary exchanger temperature stable when the boiler is not in
use. When the function is active, the display shows COMFORT
Note: this function can be activated and deactivated by pressing the COMFORT button
Timer = activated for 30 minutes
after domestic hot water draw-off
Only to test components
0 = OFF
1 = ON
0 = OFF
1 = ON
0 = OFF
1 = ON
0 = Sanitary
1 = Heating
0
0
Set parameter 260=1
0
Set parameter 260=1
0
Set parameter 260=1