Description value default setting Parameter sub-menu menu settings - adjustment - problem identification menus 2 2 4 4 BOILER PARAMETER - PART 2 3 Post-ventilation after heating request 2 4 4 2 2 2 4 4 4 5 6 7 2 2 4 4 8 9 2 2 5 5 DOMESTIC HOT WATER PARAMETER 0 COMFORT function E-COMBI EVO 2 5 1 2 5 2 2 5 3 2 5 4 2 5 5 Comfort Anti-cycling Time from 0 to 120 (minutes) 0 E-COMBI EVO Hot water flow delay from 5 to 200 (0.5 to 20 seconds) 5 Anti “water hammering” E-COMBI EVO Extinction of the burner in D. H. W. 0 = anti-scale (stop at > 67°C) 0 E-COMBI EVO 1 = + 4°C /setting Post-circulation and post-ventilation after a 0 = OFF 0 domestic hot water draw-off 1 = ON OFF = 3 minutes post-circulation and post-ventilation after domestic hot water draw-off if the boiler temperature measured requires it. ON = always on for 3 minutes post-circulation and post-ventilation after domestic hot water draw-off. Domestic hot water timer from 0 to 30 (minutes) 0 2 5 7 <Not Available> 2 5 8 <Not Available> 2 2 6 6 BOILER MANUAL SETTINGS 0 Manual mode activation 2 6 1 Boiler pump control 2 6 2 Fan control 2 6 3 3 way valve control 2 6 4 <Not Available> 42 0 = OFF 0 1 = ON Time delay after heating temperature from 0 to 60 16 Activated only with thermostat On/ increase (minutes) Off and heating control activated This parameter allows the time delay to be set before automatic increase of the flow (parameter 421 - 521 - 621 = 01) temperature calculated in increments of 4°C (max 12°C). If this parameter retains the value 00, this function is not active. <Not Available> <Not Available> Device indicator for heating circuit pressure 0 = temperature sensor only 1 = pressure switch at minimum 2 = pressure sensor <Not Available> External temperatura correction from -3 to +3 (°C) 1 RESERVED FOR TECHNICAL ASSISTANCE Only if the PCB is changed 0 Only active with external sensor connected 0 = deactivated 0 1 = timed 2 = always on The appliance allows the hot water heating comfort to be increased via the “COMFORT” function. This function keeps the secondary exchanger temperature stable when the boiler is not in use. When the function is active, the display shows COMFORT Note: this function can be activated and deactivated by pressing the COMFORT button Timer = activated for 30 minutes after domestic hot water draw-off Only to test components 0 = OFF 1 = ON 0 = OFF 1 = ON 0 = OFF 1 = ON 0 = Sanitary 1 = Heating 0 0 Set parameter 260=1 0 Set parameter 260=1 0 Set parameter 260=1