Section 8: Appendix
8.4 BASE REFERENCE POINT ADJUSTMENT
8.4.1 Adjustment of Base Reference Point for Printing
Normal Mode: PITCH OFFSET:
Adjust Pitch VR potentiometer on operator panel:
+/-49 mm (1.93”) for all media types
+/-3.75 mm (+/-0.15”) for all media types
The fine adjustment of the print position can be adjustable within the range of +3.75 mm to -3.75 mm (+0.15”
to -0.15”) using the Pitch potentiometer as described above.
Base reference
point for printing
(Print head)
Gap sensor
Label feed direction
Adjustment for
“+” value
No
Adjustment
Adjustment for
“-” value
+3.75mm (+0.15”)
-3.75mm (-0.15”)
Note:
The above base reference point for printing indicates the label stop position when label pitch sensor is set to
Gap sensor.
GZ4e Series Operator Manual
Page 8-5