3-6 Programming and Parameters No. Group File Monitor File 001 002 Parameter Name & Description See page 3-2 for symbol descriptions [Output Freq] Default: Read Only Min/Max: Units: Default: –/+[Maximum Freq] 0.1 Hz Read Only Min/Max: Units: Default: –/+[Maximum Speed] 0.1 Hz Read Only [Torque Current] Min/Max: Units: Default: 0.0/Drive Rated Amps × 2 0.1 Amps Read Only Based on the motor, the amount of current that is in phase with the fundamental voltage component. Min/Max: Units: Drive Rating × –2/+2 0.1 Amps [Flux Current] Default: Read Only Amount of current that is out of phase with the fundamental voltage component. Min/Max: Units: Drive Rating × –2/+2 0.1 Amps [Output Voltage] Default: Read Only Output voltage present at terminals T1, T2 & T3 (U, V & W). Min/Max: Units: Default: 0.0/Drive Rated Volts 0.1 VAC Read Only Min/Max: Units: Default: 0.0/Drive Rated kW × 2 0.1 kW Read Only Min/Max: Units: Default: 0.00/1.00 0.01 Read Only Min/Max: Units: Default: 0.0/214748364.0 MWh 0.1 MWh Read Only Min/Max: Units: Default: 0.0/429496729.5 Hrs 0.1 Hrs Read Only Min/Max: Units: Default: –/+[Maximum Freq] 0.1 Hz Read Only Min/Max: Units: Default: 0.0/Based on Drive Rating 0.1 VDC Read Only Min/Max: Units: Default: 0.0/Based on Drive Rating 0.1 VDC Read Only Min/Max: [Commanded Freq] [Output Current] The total output current present at T1, T2 & T3 (U, V & W). 004 005 006 007 [Output Power] Metering Output power present at T1, T2 & T3 (U, V & W). 008 32 MONITOR [Output Powr Fctr] Output power factor. 009 010 32 011 [Elapsed MWh] Accumulated output energy of the drive. [Elapsed Run Time] Accumulated time drive is outputting power. [MOP Frequency] Value of the signal at MOP (Motor Operated Potentiometer). 012 [DC Bus Voltage] Present DC bus voltage level. 013 [DC Bus Memory] 6 minute average of DC bus voltage level. 016 017 [Analog In1 Value] [Analog In2 Value] [Rated kW] Default: 0.000/20.000 mA –/+10.000V 0.001 mA 0.001 Volt Read Only Drive power rating. Min/Max: Units: Default: 0.00/3000.00 kW 0.01 kW Read Only Min/Max: Units: Default: 0.0/6553.5 VAC 0.1 VAC Read Only Min/Max: Units: Default: 0.0/6553.5 Amps 0.1 Amps Read Only Min/Max: Units: 0.000/256.256 0.001 Value of the signal at the analog inputs. Units: 026 32 Drive Data 027 [Rated Volts] The drive input voltage class (208, 240, 400, etc.). 028 [Rated Amps] The drive rated output current. 029 Related Output frequency present at T1, T2 & T3 (U, V & W). Value of the active frequency command. 003 Values [Control SW Ver] Main Control Board software version. 196