Download WEEKLY CENTRALIZED CONTROLLER FOR INDOOR UNITS
Transcript
WEEKLY CENTRALIZED CONTROLLER FOR INDOOR UNITS USER'S MANUAL DTCWT IHXR Model WARNING! PLEASE READ THIS MANUAL BEFORE USING YOUR NEW WEEKLY CENTRALIZED CONTROLLER. -1- Table of Contents SAFETY PRECAUTIONS.......................................................................................................... 3 INSTALLATION......................................................................................................................... 4 INDICATORS ON WEEKLY CENTRALIZED CONTROLLER................................................... 8 BUTTONS ON WEEKLY CENTRALIZED CONTROLLER...................................................... 10 HOW TO USE THE WEEKLY CENTRALIZED CONTROLLER.............................................. 12 ERROR CODES...................................................................................................................... 21 -2- SAFETY PRECAUTIONS Please read the Safety Precautions carefully before using DTCWT - IHXR Weekly Centralized Controller. Do observe the following Safety Precautions, for they are very important. Before reading the text, please be familiar with the following markers and icons, and comply with the Precautions. Markers Icons Markers ! ! Indication Icons Indication WARNING The sign shows the risk of death or serious injury will be caused due to the wrong operation. FORBID. Action or procedure not allowed, with serious effects on objects and people. CAUTION The sign shows the risk of injury or the damage to the property will ba caused due to the wrong operation. ENFORCE. Compulsory acton or procedure. The missed observance could bring serious effects on objects and people. • A strict observance of the following instructions will prevent personal hurt and incidents to the User. Moreover, correct operation and long life of the appliance will be ensured. • The User must never attempt to install or repair the Weekly Centralized Controller by himself. WARNING MOVE AND REPAIR CAUTION OPERATION CAUTON INSTALLATION WARNING ! Installation commitment • Please always contact the Retailer or the Authorized Technical Service for installation of the Weekly Centralized Controller. Users must not install the Weekly Centralized Controller by themselves. A wrong installation may cause electric shocks, injuries or fire. Do not spray inflammable liquid on the Weekly Centralized Controller, or fire may be caused. FORBID ! FORBID Do not operate with wet hands. Do not let water go into the Weekly Centralized Controller, to avoid the danger of electric shocks. If you want to move or re-install your Weekly Centralized Controller, please always contact the Authorized Technical Service. Do not disassemble your Weekly Centralized Controller. If you need to disassemble the Weekly Centralized Controller, please contact the Authorized Technical Service. A wrong disassembly may cause abnormal operation or overheating, which may result in fire. -3- INSTALLATION System Wiring Instructions 1. Connecting diagram for air-conditioning system with central network a) Connecting diagram 1 Indoor Unit Indoor Unit Indoor Unit Indoor Unit Indoor Unit Indoor Unit Weekly-Timer Central Controller b) Connecting diagram 2 Indoor Unit Indoor Unit Indoor Unit Indoor Unit Indoor Unit Indoor Unit Weekly-Timer Central Controller 2. Other relevant explanation There are two kinds of Indoor Unit: - Indoor Unit with built-in network module - Indoor Unit with external network module. Indoor Unit MD-NIM01 XYE Weekly-Timer Central Controller MAX=64 -4- INSTALLATION Accessory List The following is the packing list of DTCWT - IHXR Weekly-Timer Central Controller. Confirm whether it contains all accessories. Nb. Quantity Name 1 Weekly-Timer Central Controller 2 Cross-head screw 6 pieces 3 Screw anchor 6 pieces 4 User’s Manual (Installation & Operating Instructions) 1 piece 5 120 Ohm resistor for XY line 4 piece 1 piece Field installation accessories prepared Nb. Name Quantity Remarks 1 Three-core shielded cable 1 piece Used for communicating with the Indoor Unit of the air conditioning system 2 Three-core cable 1 piece Used for the supplying power to the WeeklyTimer Central Controller 3 Switch case 1 piece 4 Cable tubes 3 pieces 5 Cable tie several Used for binding cable (according to the specific situation) Installation Instructions Installation Instructions to the Central Controller: 1. Directly connect 20V~50/60Hz to ends L and N of the socket on the back of the Central Controller. 2. The signal cable and power cable of the Central Controller cannot be contained in the same cable tube. The distance between the signal cable tube and power cable shall be between 300 mm ~ 500 mm at least. 3. The total signal cable length of the Central Controller shall not exceed 1,200 m. 4. Make sure there is no joint in the middle of the shielded cable. If such a joint exists, use a socket to connect it. 5. After finishing the connection of the Central Controller, do not use megger to check the insulation of the signal cable. 6. Connecting mode between the Central Controller and network interface: The communication port between the Central Controller and the network interface of the air conditioning system is polar. The X, Y, E pins on both sides shall be corresponding and cannot be cross-connected. Correct connection Wrong connection Wrong connection -5- Wrong connection INSTALLATION Installation Method The installation method of the Central Controller using electrician switch case. The thickness of the Central Controller cable shall be adjusted according to the length of the cable. A proper cable tube shall be used to install the cable of the Central Controller. Insert the flap tip screwdriver into the 2 recesses on the top panel of the case and slightly turn to open the top cover of the Central Controller. 136 92 Dimensions: as shown in the right diagram. Installation screw hole (4) 70.5 48.5 83.5 Slightly turn flat tip screwdriver to open the top cover (2 recesses) Screws used for fixing the Central Controller Base Top cover Y E L N ON OFF COM Power connector of the Central Controller 220V/AC OFF---COM: Emergency Stop Switch, used to shut down all air conditioners. OFF---COM: Emergency Open Swith, used to start up all air conditioners. Communication interface to the Indoor Unit. -6- INSTALLATION Installation Method POWER SUPPLY= 220V/AC INDOOR UNIT (MAX) INDOOR UNIT (32) INDOOR UNIT (0) INDOOR UNIT (10) INDOOR UNIT (1) Connecting diagram of network-based air conditioning system (There are 2 types of Indoor Units: a) with external network interface module in the main control board; b) with built-in network interface module in the main control board) -7- Time -8Fan Speed: High, Middle, Low Run Mode: Auto, Cool, Heat, Fan, Dry Weekly Timer Off On-line condition matrix table of air conditioners 0-63 Economy Run Swing Query Lock Heat Operate result Electric Lock Lock Auxiliary Keyboard Remoter Heater Set Lock Cool INDICATORS ON WEEKLY CENTRALIZED CONTROLLER Indicators’ description of the Weekly-Timer Central Controller 1) General drawing of the liquid crystal display of the Weekly-Timer Central Controller INDICATORS ON WEEKLY CENTRALIZED CONTROLLER 2) LCD icon description of the Weekly-Timer Central Controller Icon Meaning Icon Meaning Automatic Mode Fan Only Mode Cool Mode Dry Mode Heat Mode Fan Speed: High/Medium/Low Electric Auxiliary Heater Lock Heat Lock Cool Lock Remoter Lock Keyboard Setting Querying Operate Result Weekly Timer Off All Online Protecting Error Set Temperature Period 1, 2, 3, 4 Room Temperature T2A Liquid Side Temp. (I.U.) T2B Gas Side Temp.(I.U.) T3 Outdoor Pipe Temp. Monday Tuesday Wednesday Thursday Friday Saturday Sunday -9- BUTTONS ON WEEKLY CENTRALIZED CONTROLLER Buttons’ description of the Weekly-Timer Central Controller 1) General key layout of the Weekly-Timer Central Controller Set Time On/Off Weekly-Timer Confirm to save Confirm Query Air Conditioner Enter the setting page of the Weekly Timer Time Weekly Program Set Air Conditioner Set Fan Speed Used to select the air conditioner to be set or queried Query Set Run Mode Set Cancel Add Reduce Per annullare l’operazione corrente Mode Set Swing Fan Swing Reset Lock Reset Default Settings Set Lock 2) Key instructions of the Weekly-Timer Central Controller Key Name Usage Press “ON/OFF” button. All air conditioners will be shut down if they are running. On the contrary, they will be started up. If you press the button for less than 5 seconds, the startup mode is the last running mode of the air conditioner. If you press the button for more than 5 seconds, the startup mode is Cooling, High Speed, 24°C. Press “SET” button and select “set single” or “set all”. “Set single” indicates to set the parameter (such as Mode/Temperature/Fan Speed/Weekly Timer) of a selected air conditioner. “Set all” indicates to set the parameter of all air conditioners controlled by the Central Controller. Press “QUERY” button to query the running condition of the air conditioner, such as On/Off, Temperature Setting, Indoor Temperature, Running Mode and Fan Speed. Press “Up”, “Down”, “Left” and “Right” buttons to select the air conditioner that you would like to query. “Up” button. When querying or setting the Indoor Unit, press this button to select the Indoor Unit to be set or queried. “Down” button. When querying or setting the Indoor Unit, press this button to select the Indoor Unit to be set or queried. - 10 - BUTTONS ON WEEKLY CENTRALIZED CONTROLLER “Left” button. When querying or setting the Indoor Unit, press this button to select the Indoor Unit to be set or queried. In setting the Weekly Timer, it is used for selecting the day of the week and the time of startup and shutdown. “Right” button. When querying or setting the Indoor Unit, press this button to select the Indoor Unit to be set or queried. In setting the Weekly Timer, it is used for selecting the day of the week and the time of startup and shutdown. When querying the Indoor Unit, press “ADD” button to query more parameter of the Indoor Unit. In setting the Indoor Unit, it is for modifying the setting temperature. In setting the Weekly Timer, it is for modifying the time of startup and shutdown. When querying the Indoor Unit, press “REDUCE” button to query more parameter of the Indoor Unit. In setting the Indoor Unit, it is for modifying the setting temperature. In setting the Weekly Timer, it is for modifying the time of startup and shutdown. When setting the Indoor Unit, it is used for setting the running mode, which includes Automatic, Cool, Heat, Fan, Dry modes and Off (shutdown of the air conditioner). You can select among them. When setting the Indoor Unit, it is for setting the fan speed, which includes High speed, Middle speed, Low speed and Automatic speed. You can select among them. When setting the Indoor Unit, it is for setting the swing function. The running mode is selected between “Swing-on” and “Swing-off”. When setting, press “LOCK” button to lock the remote controller of all or single Indoor Unit. Press the “QUERY” button and hold under the main page, then repress the “LOCK” button again to lock the keyboard of the Central Controller; press the “MODE” button and then repress the “LOCK” button to lock the running mode. If you press this button, default settings are restored, as when power is restored after a power failure. Under the main page, press “PROGRAM” button to set the Weekly Timer of “single indoor unit” or “all indoor units”. Press the “QUERY” button and hold, and press the “PROGRAM” button to query the Weekly Timer parameters of the Indoor Unit. Under the main page, press the “WEEKLY” button to start up or shut down the Weekly Timer function. Under the main page, press the “TIME” button for 5 seconds to enter the time-modifying status, and then press “ADD” or “REDUCE” button to modify the time. Press “Left” or “Right” button to select Minute / Hour / Day / Month / Year. Finally, press the “CONFIRM” button to save the modification. Save data and send the command required to the Indoor Unit, such as setting the mode of the air conditioner. Cancel Cancel the last operation and return to the last interface. - 11 - HOW TO USE THE WEEKLY CENTRALIZED CONTROLLER a) The main interface of the Weekly-Timer Central Controller (User Interface) 1) Under the other pages, press button to return to the main interface. Cancel 2) Under the other pages, automatically return to the main interface when no operation is perfomed for a period of time. 3) The main interface displays the on-line condition of the Indoor Unit. Sixty-one Indoor Units are on-line. Date The on-line condition of the Indoor Unit b) Setting interface of single Weekly-Timer Central Controller 1) Under the main interface, press of a single air conditioner. Set button to select the interface for the setting 2) Automatically return to the main interface when no operation is performed for a period of time. 3) Set the running status of a single air conditioner under this page. Indoor Net-address Room Temperature 28°C Set Temperature 20°C Cool High Speed - 12 - Setting Set Successfully HOW TO USE THE WEEKLY CENTRALIZED CONTROLLER c) Setting interface of Weekly Timer parameters of a single air conditioner 1) Under the main interface, press single Weekly Timer. Program to display the parameter setting interface of a 2) Automatically return to the main interface if no operation is performed for a period of time. 3) Under this page, set the Weekly Timer parameters of a single air conditioner, including Startup Time, Shutdown Time, the Running Mode of this period, Temperature and Fan Speed. 4) One air conditioner can be at most st with four periods in one day from Monday to Sunday, seven days in total. Period 1 Monday Time on Time off d) Unified setting interface of the Weekly-Timer Central Controller (all air conditioners) 1) Under the main interface, press Set button to display the unified setting interface. 2) Automatically return to the main interface if no operation is performed for a period of time. 3) Set the running mode of all air conditioners under this page, including Mode, Temperature and Fan Speed. Set unsuccessfully All Indoor Units Weekly-Timer off - 13 - Lock Remoter Lock Cool HOW TO USE THE WEEKLY CENTRALIZED CONTROLLER e) The operating flow description of the Weekly-Timer Central Controller 1) How to set the running status of the air conditioner? Under the main interface 1. Press Set button to enter the setting status interface of single air conditioner. Press the button repeatedly to select “Single” and “All” alternately; the display shows “Set”. If you select “Single”, press buttons to select one. 2. Selecting “All”, indicates to set the running status of all air conditioners, and “All” is displayed. Selecting “Single” displays the address of a single air conditioner: for example, if the air conditioner whose address is 12 is selected, “12#” is displayed. 3. Press Confirm button to select running mode: Automatic, Cooling, Heating, Fan Dry, or Off (shutdown of the air conditioner). If you select “Off”, press Mode button to send shutdown command, finishing shutdown setting. 4. If you select Cooling Mode or Heating Mode, press Add is within 17°C~30°C). There is no temperature adjustment for other modes. 5. Press Speed. Fan Reduce buttons to adjust the Temperature (the scope button to regulate Fan Speed, which can be selected among Automatic, Low, Middle and High 6. Press Swing button to activate automatic swinging of louver. 7. Press Confirm button to save the above setting and send input to the corresponding air conditioner. The setting is finished. 2) How to query the running status of the air conditioner? Under the main interface 1. Press Query button to enter the query status of a single air conditioner; the display shows “Query”. Press buttons to select one air conditioner. 2. Press ADD REDUCE buttons to view more parameters of the air conditioner. - 14 - HOW TO USE THE WEEKLY CENTRALIZED CONTROLLER 3) How to lock and unlock the Remote Controller of the air conditioner? Under the main interface 1. Press Set button to enter the setting status interface of a single air conditioner. Press the button repeatedly to select “Single” and “All” alternately. The display shows “Set”. If you select “Single”, press buttons to select one air conditioner. 2. Selecting “All”, indicates to set the running status of all air conditioners, and “All” is displayed. Selecting “Single”, displays the address of a single air conditioner: for example, if the air conditioner whose address is 12, “12#” is displayed. Lock 3. Press button to send the lock or unlock command of the remote controller to the corresponding air conditioner and finish setting. 4) How to lock and unlock the mode of the air conditioner? Under the main interface 1. Press Mode button and hold, then press Lock button to enter the setting interface of the mode-locking. 2. If the air conditioner is in the mode of unlocking, press buttons to select cooling-locking or heating-locking. Press Confirm button to send mode-locking command. 3. If the air conditioner is in the mode of locking, press to all air conditioners. Confirm button to send the selected unlock command 5) How to lock and unlock the keyboard of the Weekly-Timer Central Controller? Under the main interface 1. Press and hold Query button, and then press Lock 2. The keyboard will be locked if it is unlocked. If it is locked, it will be unlocked. - 15 - button. HOW TO USE THE WEEKLY CENTRALIZED CONTROLLER 6) How to set the function and relevant parameters of the Weekly Timer of the air conditioner? Under the main interface 1. Press Program button to enter the setting status interface of a single air conditioner. Press the button repeatedly to select “Single” and “All” alternately. The display shows “Set”. If you select “Single”, press to select one air conditioner. Press Confirm button to select air conditioner to the next step. Press Cancel button to cancel the selection and return to the last step. 2. Selecting “All”, indicates to set the Weekly Timer parameters of all air conditioners, and “All” is displayed. Selecting “Single” displays the address of the air conditioner: for example, if the air conditioner whose address is 12, “12#” is displayed. 3. Press buttons to select the Day of the Week. Press Cancel button to cancel the selection and return to the last step. Press Confirm button to select the day of the week to the next step. 4. Set the parameters of Period 1, including Shutdown Time, Startup Time, Running Mode, Fan Speed and Temperature. First of all, set the Startup and Shutdown Time. Press buttons to select the Startup and Shutdown Time. Press Add Reduce to modify the Startup and Shutdown Time. Press Cancel button to cancel the set of Period 1 and return to the last step. Press Confirm button to save the parameter of the Period 1 to the next step. 5. Press Mode button to select Running Mode: Automatic, Cool, Heat, Fan, Dry, or Off. If you select the Cool, Automatic or Heat mode, press Add Reduce buttons to adjust the Temperature (the scope is within 17°C~30°C). Press Fan button to regulate Fan Speed, which can be selected among Automatic speed, Low speed, Middle speed and High speed. Press Cancel button to cancel the set of Period 1 and return to the last step. Press Confirm button to save the parameter of the Period 1 to the next step. 6. Finish the Weekly Timer parameter setting of Period 1. 7. Set Periods 2, 3, 4 according to the above operation. 8. After finishing the setting of each Period, select in sequence the Days of the Week to set the parameters of the Weekly Timer from Monday to Sunday, seven days in total. Finish setting - 16 - HOW TO USE THE WEEKLY CENTRALIZED CONTROLLER 7) How to close the Weekly Timer setting related to a Period? Under the main interface 1. Press Program button to enter the setting status interface of a single air conditioner. Press the button repeatedly to select “Single” and “All” alternately. The display shows “Set”. If you select “Single”, press buttons to select one air conditioner. Press Cancel button to cancel the selection and return to the last step. Press Confirm button to select air conditioner to the next step. 2. Selecting “All”, indicates to set the Weekly Timer parameters of all air conditioners, and “All” is displayed. Selecting “Single” displays the address of a single air conditioner: for example, if the air conditioner whose address is 12, is selected, “12#” is displayed. 3. Press buttons to select the Day of the Week. Press Cancel button to cancel the set of Period 1 and return to the last step. Press Confirm button to save the parameter of the Period 1 to the next step. 4. Set the parameters of Period 1, including Shutdown Time, Startup Time, Running Mode, Fan Speed and Temperature. First of all, set the Startup and Shutdown Time. Press buttons to select the Startup and Shutdown Time. Press Add Reduce buttons to modify the Startup and Shutdown Time. Press Cancel button to cancel the set of Period 1 and return to the last step. Press Confirm button to save the parameter of Period 1 to the next step. 5. Press Mode button to select Running Mode: Automatic, Cool, Heat, Fan, Dry, or Off. Select “Off” mode. Press Confirm button to save the parameter of the Period 1 to the next step. Press Cancel button to cancel the set of period 1 and return to the last step. 6. Finish shutting down the Weekly Timer function related to Period 1. 7. Shut down the Timer during Periods 2, 3, 4 according to the above operation. Finish setting. - 17 - HOW TO USE THE WEEKLY CENTRALIZED CONTROLLER 8) How to query the Weekly Timer setting parameters of the air conditioner? Under the main interface 1. Press Query button to enter the query status of a single air conditioner. The display shows “Query”. Then press Program button to query the Weekly Timer parameters. Press buttons to select the air conditioner that needs to be queried. Press Cancel to cancel the selection and return to the last step. Press Confirm button to select air conditioner to the next step. 2. Selecting “All”, indicates to set the Weekly Timer parameters of all air conditioners, and “All” is displayed. Selecting “Single” displays the address of a single air conditioner: for example, if the air conditioner whose address is 12 is selected, “12#” is displayed. 3. Press buttons to select the Day of the Week. Press Cancel button to cancel the selection and return to the last step. Press Confirm button to select the Day of the Week to the next step. 4. Press buttons to select the Weekly Timer parameters of the queried Periods 1, 2, 3, 4. 5. Query the Weekly Timer parameters of any Indoor Unit within any time according to the above operation. 9) How to start up or shut down the Weekly Timer function of all air conditiioners? Under the main interface 1. Press Weekly button. 2. If the Weekly Timer functionis shut down, it will be started up; if the Weekly Timer function is started up, it will be shut down. 3. If the Weekly Timer function is shut down, the display shows “Weekly Timer Off”. - 18 - HOW TO USE THE WEEKLY CENTRALIZED CONTROLLER 10) How to modify the system Time? Under the main interface 1. Press button for 5 seconds to enter the Time-setting interface. Time 2. Press buttons to select Minute / Hour / Day / Month / Year that need to be modified. 3. First, press 4. Press Add buttons to select the Year that needs to be modified. Reduce 5. Press 6. Press buttons to select the Month that needs to be modified. Add Reduce 7. Press 8. Press buttons to modify the Month. buttons to select the Day that needs to be modified. Add Reduce 9. Press 10. Press buttons to modify the Year. buttons to modify the Day. buttons to select the Hour that needs to be modified. Add Reduce 11. Press buttons to modify the Hour. buttons to select the Minutes that need to be modified. 12. Press Add 13. Press Confirm Reduce buttons to modify the Minutes. button to save the modification. - 19 - HOW TO USE THE WEEKLY CENTRALIZED CONTROLLER f) Others An example to show the function of the Weekly Timer Example: Take the Indoor Unit with “04” address, set the Weekly Timer and start up the Weekly Timer function according to the procedure illustrated on the previous pages. The following Table shows an example of Timer setting. Period 1 Monday Tuesday Time on = 07:30 Time off = 18:00 Mode = Cool Temp. = 24°C Fan Speed = High Time on = 07:30 Time off = 18:00 Mode = Cool Temp. = 24°C Fan Speed = Low Period 2 Period 3 Time on = 18:30 Time off = 21:00 Mode = Fan only Temp. = Fan Speed = High Time on = 21:30 Time off = 23:30 Mode = Cool Temp. = 24°C Fan Speed = High Period 3 Time on = 18:30 Time off = 19:00 Mode = Off Temp. = Fan Speed = From the above Table, we can see that Timer has been set for 2 days every week, namely Monday and Tuesday. In particular: • Monday foresees 3 Periods of setting. Period 1: Started Time is 07:30, Shutdown Time is 18:30, Running Mode is Cool, Temperature is 24°C and Fan Speed is High. If the air conditioner is running within the set period of the Weekly Timer and another control device - as for example a wired controller - is active, the air conditioner will run according to the commands of the control device, till next Period (Period 2) of the Weekly Timer. • Tuesday foresees 1 Period of setting: in fact, as no Running Mode is set in Period 2, (Mode = Off), Timer function is not active. - 20 - ERROR CODES Error Codes on the Weekly Centralized Controller’s display Code Content EA Compressor overcurrent error EB Inverter module protection EC Freshness fault ED Fault protection of the Outdoor Unit EE Water-level detection fault EF Other faults E0 Phase-sequence error or phase-failure E1 Communication fault E2 T1 sensor fault E3 T2 sensor fault E4 T2B sensor fault E5 Compressor discharge temp. sensor, T3 temp. sensor, T4 temp. sensor error E6 Zero-crossing detection error E7 EEPROM error E8 Indoor fan-speed out of control E9 Communication fault between main board and display board 00# Communication fault between the network interface module and the main control board 01# Communication fault between the central controller and the network interface modulelo P0 Temperature protection of evaporator P1 Anti-cold air or defrosting protection P2 High temperature protection of condenser P3 Temperature protection of compressor P4 Temperature protection of exhaust pipe P5 Discharge high-pressure protection P6 Discharge low-pressure protection P7 Over-voltage or under-voltage protection P8 Compressor overcurrent error PF Altre misure di protezione - 21 - EC DECLARATION OF CONFORMITY We TERMAL Srl - 14, Via della Salute - 40132 Bologna - Italy dECLARE under our sole responsibility that HOKKAIDO Product Weekly-Timer Central Controller • DTCWT - IHXR conforms with the following directives: • EMC Directive 89/336/EEC and its following 92/31 EEC by L.D. No. 476 dated Decdmber 4th, 1992. • LV Directive 73/23 EEC and applied Standards EN 60335-2-40. NOTES TERMAL Srl 14, Via della Salute 40132 Bologna - Italy Tel. +39.051.41.33.111 Fax +39.051.41.33.112 www.termalgroup.com Due to on-going technological development of the products by the Manufacturer, we reserve the right to vary the technical specifications at any time without notice.