The circuit breaker should be resettable by the user once the overload is disconnect~.d.--- ·
This circuit breaker must be clearly labeled with instructions in~~~~~
use heavy loads.
tl4~~~-. . 'il~~
,
.
~ t\f\4'\t nn. ,
9.
The battery and controller shall be assembled in such a way a to~~ffioot Cfn - - -·· ·
case of failure) by a trained field technician at the installatk n ~H~: · With a~
functioning sub-item, of a newer design or a different brand. ~aJ'l'Ow' for future
sub-item evolution or variability of future sub-item availability. Units that are only
factory serviceable will not be accepted.
10. None of the electrical c01mections or terminals (controller, battery, plugs, sockets, fuses
. .. ) should be accessible to users. Switches, inlet/outlet plug and/or sockets and
protection fuse reset buttons (if used) should be user accessible.
11. The DC power supply board must be properly vented to allow heat dissipation and/or
gas emission.
12. The DC power supply board must also be equipped with simple but strong and reliable
features on the back side enabling the installers to solidly tie the box to any structure
inside the house.
13. The suggested design of the DC power supply board is summarized on the following