Download Code Reader 3500™

Transcript
1.8.4 - RS-232 (Serial) Cable Installation Guide
1. Attach the RS-232 (Serial) Cable to the CR3500.
2. Connect the RS-232 (Serial) cable to a serial port on the computer (Figure 1.18). There is no need to power off the
computer.
3. The RS-232 (Serial) interface has an optional 5V/1.5A power supply (Figure 1.19). If you have a power supply, plug the
power supply adapter into the RS-232 (Serial) cable and then plug the power adapter into a wall socket (Figure 1.20).
Figure 1.18
Figure 1.19
Figure 1.20
4. Once properly connected, the CR3500 will power on and beep.
5. For RS-232 (Serial) mode scan M418_02 (below). If the power supply is not connected scan M074_02 (below).
6. Scan the Save Settings Code (M188_02).
RS-232 (Serial)
RS-232 (Serial) Mode
Factory Reset
No Power Supply
RS-232 (Serial)
Factory Default Settings
Save Settings
Mode: RS-232 (Serial)
One Way Mode
Baud Rate: 57600
Stop Bits: 2
Data Bits: 8
Parity: None
Warning: Code Corporation approved power adapter must be used. Reader failure due to use of
incorrect power adapter will void warranties.
Save Settings
C004387_03_CR3500_User_Manual -
12