programming
Zones 1–8 (D8 & D16)
1
Option No.
Description
P65E
Supervised Zones
P65E
Program Mode level
Installer, Remote by PC.
Factory Default
all OFF: No Supervision zones.
Notes
0E will turn all selections OFF.
MEMORY E will turn all selections ON.
RELATED OPTIONS
P66E 1E–4E Supervision Alerts.
P66E 5E Wired Zone Supervision.
P67E Zone Supervision Time.
P92E 4E (D8) Report Supervision.
P75E 12E (D16) Report Supervision.
2
3
4
5
6
7
Zones 9–16 (D16)
8
9 10 11 12 13 14 15 16
Supervised zones
Any zone 1-8 or 1-16 can be a Supervised Zone.
In operation, a Supervised Zone is subject to the Supervision Time (P67E). If the zone/s
has not sealed or unsealed during the Supervision Time, then the programmed alerts
will turn on (as programmed by P66E 1E-4E, P92E 4E or P75E 12E). Zone Supervision
can be used as an "inactivity monitor" to sound an alert or send a dialler report if a
zone has had no activity during a set period of time. (For example, to monitor an aged
person's home).
• A zone which is permanently in a sealed or unsealed state for the duration of
Supervision Time will be treated as a Supervision alarm.
• If P66E 5E is on, Zone Supervision acts on wired zones. If P66E 5E is off, Zone
Supervision acts on radio zones.
• Each Supervised zone has its own supervision timer.
• Zone Supervision is independent of the armed state of the panel.
• Zone Supervision can be temporarily disabled by Excluding the zone/s.
• The zone which caused the Supervision alarm flashes on the keypad. Entering a
valid code + E will reset Supervision alarms.
• If Radio Supervision is enabled (P66E 5E off), then radio zones are supervised for the
absence of a supervision signal as opposed to inactivity of a zone in Wired Supervision
mode (P66E 5E on).
Programming sequence:
P65E [Zone No]E toggles the options ON and OFF
[Zone No]E OFF: The zone is not a Supervised Zone
[Zone No]E ON: The zone is a Supervised Zone
P66E 1E–8E
P67E
Program Mode level
Installer, Remote by PC.
Factory Default
Zone Supervision alerts, Supervision Time Speedup
See pages 32–33.
Supervision time
SUPERVISION TIME sets the time interval before an inactive Supervised Zone triggers
a Supervision alarm.
The SUPERVISION TIME setting is from 01 to 24 hours.
24 hours or 24 minutes.
For timing up to 24 minutes, set P66E 7E 7 8E on.
For timing up to 24 hours, set P66E 7E 7 8E off.
Notes
• A setting of less than 3 hours for radio
supervision is not recommended.
Programming sequence:
• Supervision time must be 2 minutes or
greater for correct operation.
•The Supervision timer is reset on exit
from Installer Program Mode and on Arm
or Disarm.
P67E existing time is displayed one digit at a time
[ENTER NEW TIME] E new time is displayed one digit at a time
EXAMPLE: To program SUPERVISION TIME to be 4 hours:
P67E 04E
RELATED OPTIONS
P65E Supervised Zones.
P66E 1E–4E Supervision Alerts.
P66E 7E–8E Supervision Time Speed-up.
RADIO SUPERVISION Operation
The purpose of Radio Supervision is to verify the correct operation of Ness Radio PIRs. The Supervision signal from the
Radio PIR tells the panel that the device has not been removed from radio range and is in working order.
A non-SUPERVISion enabled Radio PIR will transmit signals to the panel only when it has detected an event. Obviously,
there is no guaranteed signal period.