Download ness d8/d16

Transcript
D8/D16 V5 Options Summary
Option
P89E
Description
Default
Page
Option
48, 49
P123E 1E
1E
Enable Test Calls
ON
2E
Mains Report Delay (1 hour)
ON
3E
Listen-In to Dialler
4E
Swinger shutdown
5E
6E
7E
8E
1E
Line Fault Monitor
Enable Remote Access
OFF
2E
Enable First Call Mode
OFF
3E
Enable Remote Arming
OFF
4E
Enable Remote Disarming
5E
OFF
ON
OFF
Default
Page
ON
59
Area 1 armed output to AUX3
6E
Enable telephone remote control of AUX3
OFF
8E
Reader [x] output pulses AUX3
OFF
P124E 1E
[not used]
Description
Page 3 of 3
Area 2 armed output to AUX4
ON
59, 60
2E
Enable Extension Sonalert
5E
6E
8E
Enable AUX4 as Fail To Communicate o/p
OFF
Enable telephone remote control of AUX4
OFF
Reader [x] output pulses AUX4
OFF
P125E
Enable hardwired zones
All on
60
OFF
P130E
Real Time Clock set MINUTES
00
64
Enable Remote AUX control
OFF
P131E
Real Time Clock set HOURS
00
6E
Enable Remote Status report
OFF
P132E
Real Time Clock set DAY
01
7E
Enable Remote Event Report
OFF
P133E
Real Time Clock set MONTH
01
8E
Enable Callback Mode
OFF
04
P91E
1
52
Real Time Clock set YEAR
Required rings to answer
P134E
Report Misc. Alarms 9-14 (D8 only)
P135E
Real Time Clock set DAY OF WEEK
1, 2 on
41
1
P92E
P93E
Report Misc. Restorals 9-14 (D8 only) All on
P94E
“No Memory Warning” zones
P95E
Clear Radio Devices
P96E
Clear Memory
P97E
P90E
Use Internal Timing
OFF
[not used]
50, 51
Access Control Options
P300E
Default all Access Control options
65
P301E 1E
Use reader addresses
OFF
66
2E
Arm with double read
OFF
3E
Arm with single read and pushbutton
OFF
Clear Panel Options (restore Factory Defaults)
4E
Disarm with access card
P98E
Clear User codes, Radio Keys, Access Cards
5E
REX Input 1 (Zone 5 input)
OFF
P99E
Program the Installer code
000000
53
6E
REX Input 2 (Zone 6 input)
OFF
P101E-P116E
Program Radio devices 1–8 or 1–16
none
62
7E
REX Input 3 (Zone 7 input)
OFF
P117E 1E
Enable Output Expander
OFF
54, 55
Strobe Flash on Arm/Disarm by Reader
2E
Alternate Expander Format
8E
OFF
3E
Day Zone Follower
OFF
4E
Output Exclude
OFF
P118E
Output Expander zones
none
P119E
Output Expander alarm zones
none
P120E 1E
Latched keyswitch input
OFF
2E
Monitor Arm Chirps
OFF
3E
Radio Key AUX arms Monitor mode
OFF
4E
Keyswitch disarm only
OFF
5E
Keyswitch arm only
OFF
6E
Smart Beeps (Brief Monitor & Day modes)
OFF
P121E 1E
Zone alarms to AUX1 (P58E selects zones)
53
ON
ON
P303E
DOTL zones
none
P304E
DOTL time
20 sec
P305E 1E
DOTL output LATCHES
OFF
DOTL outputs to Output Expander
OFF
2E
3E
4E
5E
56
DOTL zone flashes on keypad
OFF
Aux Outputs
ON
P318E 1E
Ultraprox Reader1 to AUX1
OFF
2E
Ultraprox Reader1 to AUX2
OFF
3E
Ultraprox Reader1 to AUX3
OFF
4E
Ultraprox Reader1 to AUX4
OFF
P319E
Ultraprox Reader1 output TIME
5 sec
P328E 1E
Ultraprox Reader2 to AUX1
OFF
57
Zone Supervision alarms to AUX1
OFF
3E
Radio key Panic TOGGLE
OFF
4E
Radio key Panic PULSE
OFF
5E
[not used]
OFF
2E
Ultraprox Reader2 to AUX2
OFF
6E
Enable telephone remote control of AUX1 OFF
3E
Ultraprox Reader2 to AUX3
OFF
7E
Door Open Too Long (DOTL) alarm to AUX1
OFF
4E
Ultraprox Reader2 to AUX4
OFF
8E
Reader [x] output pulses AUX1
OFF
P329E
Ultraprox Reader2 output TIME
5 sec
P338E 1E
Ultraprox Reader3 to AUX1
OFF
2E
Ultraprox Reader3 to AUX2
OFF
3E
Ultraprox Reader3 to AUX3
OFF
4E
Ultraprox Reader3 to AUX4
OFF
Ultraprox Reader3 output TIME
5 sec
Zone alarms to AUX2 (P59E selects zones)
ON
2E
Zone Supervision alarms to AUX2
OFF
3E
Radio key Aux Button TOGGLE
OFF
4E
Radio key Aux Button PULSE
OFF
5E
Telephone Line fault to AUX2
OFF
6E
Enable phone remote control of AUX2 OFF
7E
Door Open Too Long (DOTL) alarm to AUX2
OFF
8E
Reader [x] output pulses AUX2
OFF
67
[not used]
[not used]
2E
P122E 1E
74
52
none
58
P339E
Ness D8x / D16x Control Panel – Installation Manual
68