Download ness d8/d16
Transcript
D8/D16 V5 Options Summary Option P89E Description Default Page Option 48, 49 P123E 1E 1E Enable Test Calls ON 2E Mains Report Delay (1 hour) ON 3E Listen-In to Dialler 4E Swinger shutdown 5E 6E 7E 8E 1E Line Fault Monitor Enable Remote Access OFF 2E Enable First Call Mode OFF 3E Enable Remote Arming OFF 4E Enable Remote Disarming 5E OFF ON OFF Default Page ON 59 Area 1 armed output to AUX3 6E Enable telephone remote control of AUX3 OFF 8E Reader [x] output pulses AUX3 OFF P124E 1E [not used] Description Page 3 of 3 Area 2 armed output to AUX4 ON 59, 60 2E Enable Extension Sonalert 5E 6E 8E Enable AUX4 as Fail To Communicate o/p OFF Enable telephone remote control of AUX4 OFF Reader [x] output pulses AUX4 OFF P125E Enable hardwired zones All on 60 OFF P130E Real Time Clock set MINUTES 00 64 Enable Remote AUX control OFF P131E Real Time Clock set HOURS 00 6E Enable Remote Status report OFF P132E Real Time Clock set DAY 01 7E Enable Remote Event Report OFF P133E Real Time Clock set MONTH 01 8E Enable Callback Mode OFF 04 P91E 1 52 Real Time Clock set YEAR Required rings to answer P134E Report Misc. Alarms 9-14 (D8 only) P135E Real Time Clock set DAY OF WEEK 1, 2 on 41 1 P92E P93E Report Misc. Restorals 9-14 (D8 only) All on P94E “No Memory Warning” zones P95E Clear Radio Devices P96E Clear Memory P97E P90E Use Internal Timing OFF [not used] 50, 51 Access Control Options P300E Default all Access Control options 65 P301E 1E Use reader addresses OFF 66 2E Arm with double read OFF 3E Arm with single read and pushbutton OFF Clear Panel Options (restore Factory Defaults) 4E Disarm with access card P98E Clear User codes, Radio Keys, Access Cards 5E REX Input 1 (Zone 5 input) OFF P99E Program the Installer code 000000 53 6E REX Input 2 (Zone 6 input) OFF P101E-P116E Program Radio devices 1–8 or 1–16 none 62 7E REX Input 3 (Zone 7 input) OFF P117E 1E Enable Output Expander OFF 54, 55 Strobe Flash on Arm/Disarm by Reader 2E Alternate Expander Format 8E OFF 3E Day Zone Follower OFF 4E Output Exclude OFF P118E Output Expander zones none P119E Output Expander alarm zones none P120E 1E Latched keyswitch input OFF 2E Monitor Arm Chirps OFF 3E Radio Key AUX arms Monitor mode OFF 4E Keyswitch disarm only OFF 5E Keyswitch arm only OFF 6E Smart Beeps (Brief Monitor & Day modes) OFF P121E 1E Zone alarms to AUX1 (P58E selects zones) 53 ON ON P303E DOTL zones none P304E DOTL time 20 sec P305E 1E DOTL output LATCHES OFF DOTL outputs to Output Expander OFF 2E 3E 4E 5E 56 DOTL zone flashes on keypad OFF Aux Outputs ON P318E 1E Ultraprox Reader1 to AUX1 OFF 2E Ultraprox Reader1 to AUX2 OFF 3E Ultraprox Reader1 to AUX3 OFF 4E Ultraprox Reader1 to AUX4 OFF P319E Ultraprox Reader1 output TIME 5 sec P328E 1E Ultraprox Reader2 to AUX1 OFF 57 Zone Supervision alarms to AUX1 OFF 3E Radio key Panic TOGGLE OFF 4E Radio key Panic PULSE OFF 5E [not used] OFF 2E Ultraprox Reader2 to AUX2 OFF 6E Enable telephone remote control of AUX1 OFF 3E Ultraprox Reader2 to AUX3 OFF 7E Door Open Too Long (DOTL) alarm to AUX1 OFF 4E Ultraprox Reader2 to AUX4 OFF 8E Reader [x] output pulses AUX1 OFF P329E Ultraprox Reader2 output TIME 5 sec P338E 1E Ultraprox Reader3 to AUX1 OFF 2E Ultraprox Reader3 to AUX2 OFF 3E Ultraprox Reader3 to AUX3 OFF 4E Ultraprox Reader3 to AUX4 OFF Ultraprox Reader3 output TIME 5 sec Zone alarms to AUX2 (P59E selects zones) ON 2E Zone Supervision alarms to AUX2 OFF 3E Radio key Aux Button TOGGLE OFF 4E Radio key Aux Button PULSE OFF 5E Telephone Line fault to AUX2 OFF 6E Enable phone remote control of AUX2 OFF 7E Door Open Too Long (DOTL) alarm to AUX2 OFF 8E Reader [x] output pulses AUX2 OFF 67 [not used] [not used] 2E P122E 1E 74 52 none 58 P339E Ness D8x / D16x Control Panel – Installation Manual 68