Safety automation system solutions Specifications Preventa™ safety PLCs Modular, XPSMF60 Rack, power supply and CPU Environment Modular safety PLC 2 Rack XPSMFGEH01 + power supply module XPSMFPS01 and central processing unit XPSMFCPU22 Products designed for max. use in safety related parts of control systems (conforming to EN 954-1, EN/ISO 13849-1 and EN/IEC 61508) Category 4 (EN 954-1), Performance level “e” (EN/ISO 13849-1), Safety integrity level: SIL 3 (EN/IEC 61508) Product certifications EN/IEC 61508, part 1-7: 2000, IEC 61511 part 1-3: 2004, DIN VDE 0116: 1989, EN 50156-1: 2004, EN 12067-2: 2004, EN 298: 2003, EN 230: 1990, NFPA 85: 2001, EN/IEC 61131-2: 2003, EN 61000-6-2: 2001, EN 61000-6-4: 2001 EN 54-2: 1997, NFPA 72: 2002 Ambient air temperature conforming to EN 61131-2 Operating °F (°C) Rack, power supply module and CPU: +32… + 140 (0…+ 60) Storage °F (°C) bb Rack XPSMFGEH01: -40… + 185 (- 40…+ 85), bb Power supply module XPSMFPS01: vv -40… + 185 (- 40…+ 85), without backup battery vv -22… + 185 (- 30…+ 85), with backup battery bb Central processing unit XPSMFCPU22: -40… + 185 (- 40…+ 85) Relative humidity Degree of protection 95% (supply not connected) Enclosure IP 20 with covering plate on unused “in rack” I/O card slots Pollution Degree of pollution II Altitude 6560 ft (2000 m) Protection class Class II, conforming to EN/IEC 61131-2 Electromagnetic compatibility Conforming to EN/IEC 61131-2 Vibration resistance conforming to EN 61131-2 Operating 1 g, frequency 10…150 Hz, unit test while operating, 10 cycles per axis Shock resistance conforming to EN 61131-2 Operating 15 g (duration 11 ms), unit test while operating, 2 cycles per axis Resistance to electrostatic discharges conforming to EN/IEC 61000-4-2 kV 4 contact, 8 air discharge Immunity to high frequency interference conforming to EN/IEC 61000-4-3 V/m 10 (26 MHz…1 GHz) Rack material Metal alloy Electrical specifications Supply Voltage V Voltage limits Output voltage of power supply module c 24 (External supply with separate protection conforming to EN/IEC 60950, SELV (Safety Extra Low Voltage) or PELV (Protection Extra Low Voltage) rated) - 15… + 20% (power supply module) - 20… + 25% V c 3.3 / 10 A V c 5 / 2A Maximum power consumption A 30 max., 32 A external fuse Immunity to momentary supply interruptions ms 10 ms Depending on size of application Protection Internal fuse Response time Backup capacitor Approximately 1 week for diagnostics and time information Program is not effected Clock Yes Operational data of CPU c 3.3 V/1.5 A c 5 V/1 A User memory Application kB 500 Data kB 500 LED display Yes Communication Ethernet network: safety communication using SafeEthernet protocol Compatibility Transmission Central processing unit XPSMFCPU22 Communication ports Baud rate Structure Introduction: page 2/38 2/46 100 Half duplex, 10 Full duplex, Autonegotiation 10BASE-T/100BASE-TX Medium Functions Integrated 4 RJ45 switched Ethernet communications ports Mbps Dual twisted pair cable, category 5D or better (Ethernet) Control of: Transmitted data: duplication, loss, bit changing. Addressing of transmitted and received messages. Data sequence: repetition, loss of data, change. Data reception time: delay, repetition, echo Diagnostics on: CPU, user program, communication, operating voltage and temperature, inputs & outputs Specifications: page 2/46 References: page 2/48 Dimensions, mounting: page 2/52 Connections: page 2/53