5. Report Codes This section addresses the report codes for all the ancillary functions. This menu consists of three sub-menus: Report Code Menu 1, Report Code Menu 2, and Report Code Menu 3. (see the SIA-Contact ID-Hex information charts on page 42 & 43). 5.1. Report Code Menu 1 Program the appropriate report codes for the following options. 5.1.1 AC Fail AC FAILURE Selections: 01-FF / Contact ID / SIA code: NO Default: No Report Select the AC fail report code that will be transmitted to the central station when an AC Fail condition occurs and the AC fail timer expires. (see 1.1.4- AC Fail Delay / 1.1.5 AC Display / 3.8.3-Rcvr Routing / SIA-Contact ID-Hex chart on page 42 & 43). 5.1.2 AC Restore AC RESTORE Selections: 01-FF / Contact ID / SIA code: NO Default: No Report Select the AC Restore report code that will be transmitted to the central station when an the AC power has been restored. (see Wiring diagram / 3.8.3-Rcvr Routing / SIAContact ID-Hex chart on page 42 & 43). 5.1.3 Low Battery LOW BATTERY Selections: 01-FF / Contact ID / SIA code: NO Default: No Report Select the Low Battery report code that will be transmitted to the central station when the voltage on the battery drops below 11.45 Vdc. (3.8.3-Rcvr Routing / SIA-Contact ID-Hex chart on page 42 & 43). 5. Report codes 1. Report Code Menu 1 1. AC Fail 2. AC Restore 3. Low Battery 4. Battery Restore 5. Box Tamper 6. Box Tamper Restore 7. Bell Fault Trouble 8. Bell Fault Restore 9. Duress 2. Report Code Menu 2 1. Bus Fault 2. Bus Restore 3. Bell Restore 4. Open Restore 5. Exit Error 6. Open Exception 7. Close Exception 8. Enter Inst. Program 9. Exit Inst. Program 3. Report Code Menu 3 1. O/C Buffer Full 2. O/C Buffer Overflow 3. Unauthorized User 4. Aux Power Fail 5. Aux Power Restore 6. Ground Fault 7. Force Arm 5.1.4 Battery Restore BATTERY RESTORE Selections: 01-FF / Contact ID / SIA code: NO Default: No Report Select the Low Battery report code that will be transmitted to the central station when the voltage on the battery reaches 11.85 Vdc. (see Wiring diagram / 3.8.3-Rcvr Routing / SIA-Contact ID-Hex chart on page 42 & 43). 5.1.5 Box Tamper BOX TAMPER Selections: 01-FF / Contact ID / SIA code: NO Default: No Report Select the Box Tamper report code that will be transmitted to the central station. (see Wiring diagram / 3.8.3-Rcvr Routing / SIA-Contact ID-Hex chart on page 42 & 43). 5.1.6 Box Tamper Restore BOX TAMPER REST. Selections: 01-FF / Contact ID / SIA code: NO Default: No Report Select the Box Tamper Restore report code that will be transmitted to the central station. (see Wiring diagram / 3.8.3-Rcvr Routing / SIA-Contact ID-Hex chart on page 42 & 43). 5.1.7 Bell Fault Trouble BELL TROUBLE Selections: 01-FF / Contact ID / SIA code: NO Default: No Report Select the Bell Fault Trouble report code that will be transmitted to the central station when the SMDC detects a trouble condition on the Bell 1 circuit. (see Wiring diagram / 3.8.3-Rcvr Routing / SIA-Contact ID-Hex chart on page 42 & 43). Optex Inc. - 1845 W 205th St. - Torrance, Ca. 90501 - 800-966-7839 SMDC-16 Program Manual 39 of 59 3440-0252 A4