ENDRUN TECHNOLOGIES S is the Signal Processor State, one of 0 (Acquiring), 1 (GPS Locking), 2 (GPS Locked). N is the number of GPS satellites being tracked, 0 to 8. VCDAC is the oscillator Voltage Control DAC word, 0 to 65535 with larger numbers implying higher oscillator frequency. Typical range is 20000 to 38000. SN.R is the carrier Signal to Noise Ratio, 0.00 to 99.9, measured in dB in the GPS data rate bandwidth. Typical range is 30 to 45. FLTS is the fault status, which displays the current summary status of the GPS timing subsystem. The summary status is contained in sixteen bits which are displayed in four hexadecimal characters. Assertion of any of these bits will also be indicated by illumination of the red LED. Each bit of each character indicates the status of a subsystem component: Hex Character 0 1 Bit 3 FLASH Write Fault Antenna Fault 2 Not Used Bit 2 FPGA Config Fault No Polling Events Not Used 3 Not Used Not Used DAC Control Over-Range Bit 1 No Signal Time-Out Not Used Bit 0 DAC Control Over-Range Not Used Not Used Not Used Not Used Not Used This bit indicates that the electronic frequency control DAC for the oscillator has reached either the high (55000) or low (10000) limit while locked to the GPS signal. Unless the unit is being subjected to out-ofspecification environmental conditions, this would indicate that the oscillator frequency has drifted near to the end of life region. This should normally only occur after about ten years of operation. The unit will continue to function until the oscillator frequency finally reaches one of the actual DAC endpoints. The unit should be returned to the factory for oscillator replacement at the customer’s convenience. 55 Tempus Gntp User’s Manual