Download SB3000tl-4000tl-5000..
Transcript
SMA Solar Technology AG Technical Data 13 Technical Data SB 3000TL-20 SB 4000TL-20 SB 5000TL-20 PV generator connection data Max. input voltage Input voltage, MPP range Max. input current Max. input power Number of MPP trackers Max. number of strings (parallel) Voltage ripple Operating consumption a) UDC max UPV IPV max PDC Uss The maximum open circuit voltage, which can occur at a cell temperature of -10 °C, may not exceed the maximum input voltage. Grid Connection Data Nominal output power Max. output power Nominal output current (at 230 V AC) Max. output current Max. fuse protection Harmonic distortion of output current PACnom 3000 W 4000 W PACmax IACnom 3000 W 13 A 4000 W 17.4 A IACMax 16 A 22 A 32 A <4% KIAC PAC > 0.5 PACnom) Nominal AC voltage Operating range AC grid frequency Operating range Power factor (at nominal output power) Overvoltage category Test voltage (50 Hz) Test surge voltage Internal consumption at night 4600 W / 5000 Wb) 5000 W 20 A 22 A < 3 % at PACNom) (at KUgrid < 2 %, b) 550 V a) 125 V DC ... 440 V DC 17 A 2 x 15 A 3200 W 4200 W 5300 W 1 2 2 2x2 < 10 % of the input voltage < 10 W UACnom UAC fACnom fAC cos phi 220 V, 230 V, 240 V 180 V - 280 Vb) 50 Hz, 60 Hz / ± 5 Hz 45 – 65 Hzb) 1 III 1.4 kV (1 s routine testing / 5 s type testing) 4 kV (serial interface: 6 kV) < 0.5 W depending on country configuration Installation Guide SB30TL_40TL_50TL-IEN085120 69