Download System Administrator Guide (Windows)

Transcript
Chapter 5
FLEXlm Licensing Tools
Connection Problems
symptom
The application program (or lmstat) cannot connect to the
server to check out a license.
cause
The FLEXlm routines in the application are unable to make a
TCP connection to the server and port specified in the license
file. Possible reasons for this are:
solution
© National Instruments Corporation
1.
The wrong license file is being referenced by the
application program.
2.
The server machine specified in the license file is down.
3.
The vendor daemon specified in the license file is not
running.
4.
The hostname in the license file is not recognized by
the system.
5.
The network between the client machine and the server
machine is down.
6.
TCP is not running on your machine.
Verify that the application is using the proper license file.
Verify that the specified server machine is up and reachable by
executing another command that uses TCP, such as rsh or
rlogin, from the client to the server. Verify that the vendor
daemon is running (you can use the ps command on the server
to look for it). Examine the license log file to see if any
problems are reported, particularly messages indicating that
the vendor daemon has quit. Run lmstat -a from the server
machine to verify that the vendor daemon is alive. Run
lmstat -a from the client machine to verify the connection
from client to vendor daemon across the network. Try using
telnet hostname portnum where hostname and
portnum are the same as on the server line in your license
file.
5-11
MATRIXx System Administrator Guide (Windows)