Chapter 8: Large Signal Periodic AC, Transfer Function, and Noise Analyses
Multitone Harmonic Balance AC Analysis (.HBAC)
Input Syntax
.HBAC frequency_sweep
Parameter
Description
frequency_sweep
Frequency sweep range for the input signal (also referred to
as the input frequency band (IFB) or fin). You can specify LIN,
DEC, OCT, POI, or SWEEPBLOCK. Specify the nsteps, start,
and stop frequencies using the following syntax for each type
of sweep:
■
■
■
■
■
■
LIN nsteps start stop
DEC nsteps start stop
OCT nsteps start stop
POI nsteps freq_values
SWEEPBLOCK nsteps freq1 freq2 ... freqn
DATA=dataname
HBAC Analysis Options
The following options directly relate to a HBAC analysis and override the
corresponding PAC options if specified in the netlist:
■
.OPTION HBACTOL, default = 1x10-8, Range = 1x10-14 to Infinity
■
.OPTION HBACKRYLOVDIM, default = 300, Range = 1 to Infinity
■
.OPTION HBACKRYLOVITER | HBAC_KRYLOV_ITER, default = 1000,
Range = 1 to Infinity
If these parameters are not specified, then the following conditions apply:
■
If HBACTOL > HBTOL, then HBACTOL = HBTOL
■
If HBACKRYLOVDIM < HBKRYLOVDIM, then HBACKRYLOVDIM =
HBKRYLOVDIM
Output Syntax
This section describes the syntax for the HBAC .PRINT and .PROBE
statements. These statements are similar to those used for HB analysis.
.PRINT and .PROBE Statements
.PRINT HB TYPE(NODES | ELEM)[INDICES]
HSPICE® User Guide: RF Analysis
E-2010.12
191