Download FINAL DRAFT prEN 12445
Transcript
Page 21 prEN 12445:2000 When moved in the door aperture in any position between locations A and B (see figure 13), the A test piece 1, placed on the inside, shall be detected by the inside presence detection equipment, and the A test piece 2, placed on the outside, shall be detected by the outside presence detection equipment. Dimensions in millimetres Figure 13 — Testing two coupled presence detection devices 7.2.2 Testing of hinged and folding doors 7.2.2.1 Detection active on one side When the door is in the worst position, if one exists, and the A test piece is located on the ground (see figure 14), it shall be detected. Dimensions in millimetres Key 1 Side of presence detection Figure 14 – Testing a presence detection with the A test piece on a hinged door 7.2.2.2 Detection active on both sides The projections of the door leaf, when closed and opened, are first drawn on the ground. Then the leaf is located in a half closed position. When the door leaf is half closed, the two A test pieces located on the ground (see figure 15) shall be detected: the A test piece1 shall be detected by the inside presence detection, and the A test piece 2 shall be detected by the outside presence detection.