3.7 Description of controls The control window is divided in different zones grouping the available commands by type and function. The main zones are: ALARMS divided in: • Last Field • WARNING • ALARM • Averaging Period • Battery Section • Device Section • Over Heat • Case OPEN • NOTIFY ALARMs through Storing Settings with the subcommands: • Rate • Peak The Storing Setting affects the memory duration before old data are overwritten. P.Time: Processing time. It mainly depends on the Bands setting. The minimum Rate should be, at least, =10 x Processing time. Schedule for MODEM divided in: • Telephone number • Time (HH:mm) • Stand by (H) • Every (H) • Originate CALL Up to 10 fixed phone numbers can be programmed. The first phone number which is free and allows the data download will interrupt the search for the other number. Schedule for SMS divided into: • Telephone number • Time (HH:mm) • Stand by (H); this value affects battery duration • Every (H) • Send REPORT Up to 10 mobile phones can be programmed. All the mobile phones will receive the daily report. Get DATA divided in: • Start with the subcommands - Since Last Time - From MRK# - Date & Time The starting date must be not later than the Stop date. Starting date cannot be before “First Valid Date” displayed on the lower left side of the control window: 3-30 Instructions for use