Download PGT-09-S Programming Tool and Analyzer
Transcript
Manual PGT-09-S® Event mode record format: The record fields are defined as follows: Record index Event code Timestamp of the event Watch signal changes related to an event Additional notes: Event codes are identified as follows: o W identifies changes in watch signals o <<T>> identifies a trigger reference o TOVF! identifies a timestamp overflow (if any) the timestamp can have different resolution depending on the acquisition mode: o full (23bit,13.56 ns) all modes but Message mode o reduced (14bit, 694 ns) Message mode In the bottom section a bar is placed showing both the number of acquired records and those listed. Also, a push button is available to enable or disable storage of records in the PGT-09-S device. Note that the data acquisition is buffered and the buffer is dimensioned to store up to 2048 records. Trigger The acquisition trigger allows to log data only under specific conditions. Setting the trigger also allows the user to synchronize acquisition to an external signal (refer to the TRIGGER connection, chapter 3.4). Please note that to configure the trigger based on an external signal the trigger source must include the “AUX” bit of the POSITION events byte. Please note that the trigger is disabled on startup. If the trigger is disabled, all data on the HIPERFACE DSL® link is logged when starting an acquisition. 8013604/ WT29 SICK STEGMANN GmbH Subject to change without notice 57