Download SoMat eDAQ
Transcript
SoMat eDAQ The outputs are generated from a D/A converter implemented as a unity gain follower to the A/D converter. The eDAQ uses the non-inverting unity gain follower by default. Select the analog output inverting option in the ECPU hardware configuration to use the inverting unity gain follower. NOTE The EHLS uses a nominal ±2-volt A/D converter. However, do not assume that the user-defined full-scale values are even approximately equivalent to ±2 volts for any particular channel. This is primarily because TCE automatically provides a minimum overrange protection of 1% and the eDAQ can set gains only at certain discrete values resulting in actual overrange protection that is sometimes significantly larger than 1%. TCE provides the option to generate an AOM calibration file which is an ASCII file containing all of the information required to scale the analog output signal voltages to equivalent engineering values. The file also includes SIE or SIF file analog output scale and offset keywords for each channel stored in a Time History DataMode. Select Save AOM File from the Test Control menu to generate the file. For more information on the AOM file, see “AOM Calibration File” on page 72. 5.8 SMART Modules SMART module adapters act as an interface between a transducer and an EHLS input channel which powers the module. Each SMART module provides specialized signal conditioning as a front end to the EHLS signal conditioning and includes independent self-identification capabilities and self-calibration parameters. The following table lists the available SMART modules. SMART Module Order Number Description SMSTRB4 Strain SMART Module 1-SMSTRB4-120-2 or The SMSTRB4 supports full-, half- and quarter- bridge transducers and includes 1-SMSTRB4-350-2 5- and 10-volt excitation options and internal shunt calibration using either 50or 100-kilohm shunt resistors with both upscale and downscale shunting options. SMITC Thermocouple SMART Module 1-SMITC-2 The SMITC supports fully-isolated thermocouples of type J, K, T or E over the full temperature range of the thermocouple. For more information on setting up SMART module input channels, see “SMART Module Input Channels” on page 125. For information on wiring SMSTRB4 inputs, see “SMSTRB4 (Strain SMART Module)” on page 218. Installation The eDAQ does not sense when a SMART module is installed or removed. After connecting a module, either cycle the eDAQ power or perform a hardware query to detect the installed SMART module. In both of these cases, the eDAQ applies power and sends a query to all EHLS channels that support SMART modules. Note that the SMART modules remain in a default configuration until an action such as starting a I2740-1.1 en 105