9000X AF Drives August 2010 Description of Parameters 507 DC-braking current 234567 (P1.4.8) Defines the current injected into the motor during DC-braking. 508 DC-braking time at stop 234567 (P1.4.9) Determines if braking is ON or OFF and the braking time of the DC-brake when the motor is stopping. The function of the DC-brake depends on the stop function, ID506. 0.0 DC-brake is not used >0.0 DC-brake is in use and its function depends on the Stop function, (ID506). The DC-braking time is determined with this parameter. Par. ID506 = 0; Stop function = Coasting: After the stop command, the motor coasts to a stop without control of the frequency converter. With DC-injection, the motor can be electrically stopped in the shortest possible time, without using an optional external braking resistor. The braking time is scaled according to the frequency when the DC-braking starts. If the frequency is ≥ the nominal frequency of the motor, the set value of parameter ID508 determines the braking time. When the frequency is ≤10% of the nominal, the braking time is 10% of the set value of ID508. fout fout fn fn Output Frequency Motor Speed Output Frequency 0.1 x fn DC-Braking ON DC-Braking ON t t t = 0.1 x ID508 t = 1 x ID508 RUN STOP Motor Speed RUN STOP Figure 8-43: DC-Braking Time when Stop Mode = Coasting MN04004001E For more information visit: www.eaton.com 8-53