‘DS401’ mode without internal I/O-master/slave cascading (default setting)
(predefined connection set according to DS301 V3.0 chapter 8.4.1)
Function
network management
(basic, NMT-master ® NMT-slave)
network management
(ext., NMT-slave ® NMT-master)
emergency message
PDO (tx) (e.g. digital inputs 1...8)
PDO (rx) (e.g. digitaloutputs 1...8)
SDO (tx) from I/O-master module to the control system
SDO (rx) from the control system to the I/O-master module
node guarding
(identifier distribution only by NMT-boot up)
Identifier
0
Identifier Number
max
0
1
2025
2025
1
128 + add
384 + add
512 + add
1408 + add
1536 + add
1792 + xxx
255
511
639
1535
1663
2015
127(*)
127
127
127
127
255
(*)
127 node-IDs are only available, if the ‘internal master/slave cascading’ is not used (that means if no modules
are linked to form a ‘logical module’).
48
CAN-CBM-DIO8 Manual Rev. 0.83