Download Overload Warning System DS 50
Transcript
DS50 TROUBLE SHOOTING MANUAL LEVEL 3 11. ERROR CODE MESSAGES Error Code Error E5 7 E-Eprom Error. Cause E-Eprom was not initialized. Sometimes prior to calibration or prior to transferring data into a replacement unit. Remedy Follow the instruction of the troubleshooting manual level 3 to initialize the system. Caution: The initializing procedure erases all existing calibration. The system must be recalibrated or other valid data transferred. Refer to troubleshooting manual level 3. Defective E-Eprom - when the If in doubt contact PAT E-Eprom was loaded with service support. Replace calibration data previously. main board or central unit and transfer original EEprom data. A copy of the original calibrated data file must be obtained from the Crane manufacturer or PAT - Service department. Caution: In some cases a recalibration of the system is necessary. Load test system after. Remark If an error message is displayed that is not listed, please immediately contact the competent PAT service department. TSM DS 50-003/REV.B/031-300-190-003/12-02-96 48