QUICK START PROGRAMMING
Setting Single code operation
Follow the steps below to program the K50 keypad for single code
operation.
1)
Enter the six digit master code, as found inside the
front cover of the manual, then press the # button.
2)
Press # button again.
3)
Enter your four to eight digit user code then press
the # button.
4)
Press # button again.
The LED’s should now be off and the keypad is ready to use.
Deleting a Single code
Follow the steps below to delete a single code from the K50 keypad.
1)
Enter the six digit master code, as found inside the
front cover of the manual, then press the # button.
2)
Press 9 followed by the # button.
3)
Enter your four to eight digit user code to delete then
press the # button.
4)
Press # button again.
5)
Press * button
The LED’s should now be off and the keypad is ready to use.
For further programming options see over for the Programming
Summary Table or for full programming instructions view the
programming section starting on page 11 of manual.
Enter Master code here for quick reference.
Factory set
master code :
User set
master code:
RAYTEL SECURITY SYSTEMS LIMITED
Access Control Keypad
Table of Users and Keypad Parameters
Installation Company: ………………………..……………….
Tel: ……………………….……………
Date: ….………….…...…
Name of On-Site Programmer(s): …………………………………………..………………………………………………….…………………….....
Master Code FMC: …………………….………..…….……………...….…..…. UMC (If Set): …………..…..……..….…….……..…..…….…….
Unit Type: ……….…..………..………………….….. Lock Time: .……..……..…Seconds
Serial Number: .……………………....….……
Time Zone Periods:
TZ1 from
to
(If Set)
TZ2 from
to
TZ3 from
to
TZ4 from
to
TZ5 from
to
Latch Mode Time:
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
NAME
from
to
Service Mode Time:
CODE
TIME ZONE
from
LATCH CODE
to
SERVICE CODE
DATE
50
We recommend this page should be filled in and regularly updated and kept in a safe and secure location by the person responsible for the upkeep of the system.
The Digitac K50
Access Control System
Installation and User Manual
Issue 2 – May 2001
IMPORTANT NOTE
Please keep this manual in a safe
place with the premises Key holder.
The Factory Master Code is inside.
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
Factory Master Code
The Factory Master Code allows access to the programming modes of the K50. It is
recommended that this manual be kept in a safe place for future reference.
Factory Master Code
VERY IMPORTANT PLEASE KEEP SAFE
Unit Serial Number
If the Factory Master Code is reprogrammed the new User Master Code should be
noted below.
User Master Code
Declaration of Conformity
We, Raytel Security Systems Ltd, declare that the equipment
referred to within this document, conforms to the European
Commission Electromagnetic Compatibility (EMC) Directive
(Directive 89/336/EEC) when installed in strict accordance with
the guidelines contained within this document.
Technical Support
For all technical enquiries relating to this equipment, engineers are available at the following addresses:
Rayleigh Office
Glasgow Office
Raytel House
Brook Road
Rayleigh
Essex
SS6 7XH
Unit 3, Block 5
Oakbank Industrial Estate
Garscube Road
Glasgow
G20 7LU
Tel:
Fax:
Tel
Fax
(01268) 749310
(01268) 745001
(0141) 3324232
(0141) 3326952
Raytel Security reserves the right to change the content of this manual and product
design without prior notice.
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
1
Index
GENERAL DESCRIPTION..................................................................................................................4
OPERATION ..........................................................................................................................................4
AUDIBLE AND VISUAL INDICATIONS ....................................................................................................4
• Key press Confirmation. ...........................................................................................................4
• Valid Code. ...............................................................................................................................4
• Invalid Code .............................................................................................................................4
• Invalid Data..............................................................................................................................4
ADDITIONAL FEATURES ......................................................................................................................5
Code Entry Timer ............................................................................................................................5
Code Capacity ..................................................................................................................................5
Master Code .....................................................................................................................................5
Timed Code Operation.....................................................................................................................5
Tamper Switch .................................................................................................................................5
Timed Lock Operation.....................................................................................................................5
Exit Button.......................................................................................................................................5
Service Mode....................................................................................................................................5
Latch Mode ......................................................................................................................................6
Self Test............................................................................................................................................6
Master Reset.....................................................................................................................................6
INSTALLATION ...................................................................................................................................7
CONTROL UNIT ....................................................................................................................................7
SEALING ...............................................................................................................................................7
POWER SUPPLY ....................................................................................................................................7
ELECTRIC RELEASE.............................................................................................................................7
EXIT BUTTON .......................................................................................................................................7
CABLE COLOUR CODE.........................................................................................................................8
WIRING SCHEMATICS ......................................................................................................................9
WIRING FOR K50 USING AN AC SUPPLY WITH AN AC FAIL SECURE RELEASE .............................9
WIRING FOR K50 USING A DC SUPPLY AND DC FAIL SECURE RELEASE.........................................10
WIRING FOR K50 USING A DC SUPPLY AND DC FAIL SAFE RELEASE .............................................11
WIRING FOR K50 TAMPER RELAY AND DC FAIL SAFE RELEASE ...................................................12
WIRING FOR K50 TAMPER RELAY AND DC FAIL SECURE RELEASE ...............................................13
WIRING FOR KA1-KA3 AND AC FAIL SECURE RELEASE ................................................................14
WIRING FOR KA1-KA3 AND ELVOX GATE SYSTEM ........................................................................15
WIRING FOR KA1 – KA3 WITH DC FAIL SAFE RELEASE.................................................................16
WIRING FOR KV1 SYSTEM AND AC FAIL SECURE RELEASE ...........................................................17
WIRING FOR KV1 – KV3 AND AC FAIL SECURE RELEASE ..............................................................18
QUICK PROGRAMMING GUIDE. ..................................................................................................19
PROGRAMMING A CODE.....................................................................................................................19
DELETING A CODE..............................................................................................................................19
SETTING THE LOCK RELAY TIME .....................................................................................................20
ACTIVATING THE K50 SELF TEST MODE ...........................................................................................20
K50 Test sequence .........................................................................................................................21
ADVANCED PROGRAMMING GUIDE. .........................................................................................22
PERFORMING A MASTER RESET .......................................................................................................22
SETTING THE LOCK RELAY TIME .....................................................................................................23
INSTALLING USER CODES..................................................................................................................24
SETTING THE CLOCK .........................................................................................................................25
SETTING SERVICE MODE...................................................................................................................26
To Enter Service Mode Manually .................................................................................................26
To exit Service mode......................................................................................................................26
To Set Service Mode for timed operation......................................................................................26
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
2
Index
SETTING LATCH MODE .....................................................................................................................27
To Enter Latch Mode Manually....................................................................................................27
To exit Latch mode ........................................................................................................................27
To Set Latch Mode for timed operation ........................................................................................27
SETTING SOUNDER OPERATION.........................................................................................................28
CODE CAPACITY CHECK ...................................................................................................................29
ACCESS LEVELS AND TIME ZONES ...................................................................................................30
Programming Time Zone settings.................................................................................................31
DELETING A SINGLE USER CODE .......................................................................................................32
DELETING ALL USER CODES.............................................................................................................33
CHANGING THE MASTER CODE ........................................................................................................34
TECHNICAL INFORMATION .........................................................................................................35
PROGRAMMING SUMMARY TABLE ...........................................................................................36
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
3
General Description
General Description
The K50 is a compact self-contained
access control unit, (which may also be
incorporated into audio and video
entrance panels), designed for single
door operation. Installation is quick and
simple, with all programming done via
the keypad.
Typical K50
Installation
Open
Area
Secure
Area
Power
Supply
Mains
Operation
K50
A person wishing to gain access to the
secure area will enter their user code via
Electric
the keypad. If the correct code has been
Release
Exit
entered the lock output relay will operate
Push
for the pre-set time. If the code entered is
incorrect, subsequent key presses will be ignored for six
seconds, the last two seconds of which will be accompanied by a continuous
error tone. This makes code breaking by trial and error more difficult.
Audible and visual indications
During normal operation of the K50 the following audible / visual responses
will be encountered.
•
Key press Confirmation.
When a button is pressed, except the *, the K50 will respond with a
short tone accompanied by the RED LED flashing on / off.
•
Valid Code.
When a valid user code is entered or the exit button is operated the
output relay will operate for a pre-set time. A tone and illumination of
the GREEN LED accompany this. This will continue while the output
relay is in operation.
•
Invalid Code
If an invalid code is entered the K50 waits four seconds before
sounding a low frequency tone; this is accompanied by the illumination
of the RED LED. This error tone lasts for two seconds.
During program mode in addition to the Key press Confirmation and the
indications as detailed in the individual programming tables the following
audible / visual response may be encountered.
•
Invalid Data.
If invalid data is entered e.g. trying to add a user code that already
exists the K50 will emit a low frequency tone; this is accompanied by
the illumination of the RED LED. This error tone lasts for two
seconds.
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
4
General Description
Additional Features
Code Entry Timer
A delay of more than four seconds between successive key presses will
register as an incorrect code, subsequent key presses will be ignored for six
seconds, the last two seconds of which will be accompanied by a continuous
error tone.
Code Capacity
The K50 has the capacity to store up to fifty access codes of four to eight
digits. The codes are stored in EPROM and therefore will be retained even if
the power is removed.
Master Code
The Master code is used to access all the programming features. Each unit is
factory programmed with its own unique master code. This code can be found
on the inside cover of this manual. For additional security it is possible to
reprogram the master code. The new code should be noted in the space
provided inside the front cover of this manual, which should then be kept in a
restricted, secure location.
Timed Code Operation
During normal operation, entering a valid code at any time will activate the
door release. Optionally up to two sets of time zone markers may be
programmed into the controller giving six access periods. This allows
different codes to be assigned to different security levels. Please refer to the
section on Access Levels and Time Zones starting on page 30 of this manual.
Tamper Switch
When the unit is installed the tamper switch lever is depressed by contact
against the mounting surface. This makes a short circuit between the two
tamper alarm cables (yellow and white cables in multicore). If the unit is
removed, the tamper switch opens breaking the circuit between the two tamper
alarm cables. This change in state may be used to operate a remote alarm if
required.
Timed Lock Operation
The lock output relay operation time is adjustable between one and ninety nine
seconds in one-second increments.
Exit Button
A normally open push button may be fitted to give lock operation from within
the secure area.
Service Mode
During service mode operation, pressing any button on the keypad will operate
the lock output relay for the pre-set lock time. This option is designed for use
with fail secure releases.
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
5
General Description
Latch Mode
Latch mode is used to latch the lock output relay on. This can be done
manually, using the master code to turn latch mode on or off or, programmed
to automatically operate during certain access periods. This option is only
recommended for use with fail safe door releases.
Self Test
The unit has a self-diagnostic mode. When entered it allows the controller and
keypad functions to be tested with audible and visual confirmation of the
results.
Master Reset
The master reset will clear all user codes and reset all functions to their factory
defaults, including the factory user code.
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
6
Installation
Installation
Control Unit
The control unit should be securely attached to a wall adjacent to the entrance
that it controls. Care should be taken to establish that the wall upon which the
unit is to be mounted is of sufficient size and construction to meet the
dimensions and weight of the control unit.
If any risk of flooding or free flowing water is apparent, the control unit
should be fitted in a position that will provide adequate protection from the
ingress of moisture.
The control unit should be mounted at such a height, approximately 1.3
meters, 1.5 meters for integrated audio / video panels, that it can be used
without undue difficulty.
Sealing
Ensure the unit is adequately sealed, using a flexible sealing compound, to
prevent moisture ingress. The unit should be sealed on the top, left and right
edges, the bottom edge should be left unsealed to allow for drainage and
ventilation. For flush installations, ensure that the front edge of the flush box
is installed level with the mounting surface such that when the front panel is
fitted, it rests against this edge without gaps.
Power Supply
The K50 requires a supply of 10 – 16V AC or 10 – 28V DC at 100mA. This
should be located on an inside wall within the secure area and supplied with
240V 50Hz AC mains. If the K50 is to function during mains failure a 12V
DC supply with a battery standby facility should be used.
Electric Release
This should be fitted according to the manufacturer’s instructions and comply
with the relevant statutory regulations. Note that only 12V DC releases can be
used if the unit is to operate during main failure. It is strongly recommended
that a break glass unit be fitted on installations using fail safe releases. For
installations using fail secure releases a mechanical override e.g. internal
handle should be fitted.
Exit Button
This should have normally open contacts and be located within the secure
area.
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
7
Installation
Cable Colour Code
The K50 comes supplied with two meters of twelve-core cable. The following
chart gives details of core usage.
Cable Colour
Red
Black
Yellow & White
Green & Blue
Violet & Brown
Grey & Turquoise
Orange & Pink
Usage
Power input + ve
Power Input - ve
Tamper Switch Output
Exit Button Input
Clean Contact Output (Common)
Clean Contact Output (Normally Closed)
Clean Contact Output (Normally Open)
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
8
5
8
4
7
9
6
3
ACCES S
DE SCRIP T ION
INIT IAL
ISS
1
DIGITAC
0
2
K50
1
FUNCT ION
DAT E
NC
COM
NO
EXIT
TAMPER
EXIT
CHE CKED
DRAWING No.
BPM
DRAWN
25 - 4 - 95
DAT E
RGD 5006 / 15
APPROVE D
INDICATES OPTIONAL
WIRING AND EQUIPMENT.
EXIT BUTTON
MODEL - SE1
( VARIANTS VSE1 & VFE1 )
TAMPER ALARM OUTPUT
NORMALLY CLOSED LOOP
MAINS VOLTAGE
230 Vac 50 Hz
12 Vac POWER SUPPLY
MODEL - 832/000
TAMPER
TAMPER
12Vac
12V
12 V ac 2 0 V A.
TITLE
INSTALLATION WIRING SCHEMATIC
FOR ACCESS CONTROLLER K50
OPERATING FROM AN AC SUPPLY.
DOOR RELEASE
FAIL SECURE ( LOCKED )
GREEN
BLUE
ORANGE & PINK
Primary
0832/000 Secondary
240 V ac 50/60 Hz.
ELVOX
Art.
JUNCTION BOX
MODEL - JB720
GREY & TURQUOISE
WHITE
VIOLET & BROWN
RED
BLACK
YELLOW
THE RAYTEL GROUP LTD.
MULTICORE
CABLE
2 metres.
25 - 4 - 95
ACCESS CONTROLLER
MODEL - K50
( VARIANTS K50S & K50B )
SECURE AREA
Wiring Schematics
Wiring Schematics
Wiring for K50 using an AC supply with an AC Fail Secure release
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
9
9
5
8
4
7
DE SCRIP T ION
INIT IAL
ISS
1
DIGITAC
0
6
2
3
ACCE SS
1
K50
FUNCT ION
2 - 5 - 95
DAT E
MULTICORE
CABLE
2 metres.
ACCESS CONTROLLER
MODEL - K50
( VARIANTS K50S & K50B )
RED
BLACK
YELLOW
DOOR RELEASE
FAIL SECURE ( LOCKED )
GREEN
BLUE
ORANGE & PINK
-
NO
EXIT
TAMPER
TAMPER
12Vdc
+
13.8 V
L
E
N
EXIT
TAMPER
EXIT BUTTON
MODEL - SE1
( VARIANTS VSE1 & VFE1 )
TAMPER ALARM OUTPUT
NORMALLY CLOSED LOOP
12 V BATTERY ESSENTIAL
FOR TIMEZONE OPERATION
CHE CKED
2 - 5 - 95
DAT E
RGD 5006 / 21
APPROVE D
INDICATES OPTIONAL
WIRING AND EQUIPMENT.
DRAWING No.
BPM
DRAWN
MAINS SUPPLY
230 Vac 50 Hz.
INSTALLATION WIRING SCHEMATIC
FOR ACCESS CONTROLLER K50
OPERATING FROM A DC SUPPLY.
TITLE
NC
COM
JUNCTION BOX
MODEL - JB720
GREY & TURQUOISE
WHITE
THE RAYTEL GROUP LTD.
-
+
TAMP
+
+
BATT
OUT
POWER SUPPLY UNIT
MODEL - 1381LM
F 2A
VIOLET & BROWN
SECURE
AREA
Wiring Schematics
Wiring for K50 using a DC supply and DC Fail Secure release
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
10
9
#
8
0
7
DE SCRIPT IO N
INIT IAL
ISS
1
DIGITAC
6
5
4
3
2
1
FUNCT IO NA CCE SS
K50S
ACCESS CONTROLLER
MODEL - K50S
( VARIANTS K50 & K50B )
26 - 4 - 95
DA T E
+
-
TAMP
+
BATT +
OUT
DOOR RELEASE
FAIL SAFE ( OPENED )
COM
NC
NO
EXIT
TAMPER EXIT
OPERATING FROM A DC SUPPLY.
FOR ACCESS CONTROLLER K50S
CHECKE D
26 - 4 - 95
RGD 5006 / 16
AP PRO VE D
DA T E
( VARIANTS VSE1 & VFE1 )
MODEL - SE1
EXIT BUTTON
TAMPER ALARM OUTPUT
NORMALLY CLOSED LOOP
12 V BATTERY ESSENTIAL
FOR TIMEZONE OPERATION
INDICATES OPTIONAL
CABLING AND EQUIPMENT
DRAWING No.
BPM
DRAWN
MAINS SUPPLY
230 Vac 50 Hz.
TAMPER
TAMPER
+
12Vdc
13.8 V
L
E
N
INSTALLATION WIRING SCHEMATIC
TITLE
EMERGENCY RELEASE
MODEL - BG1
GREEN
BLUE
ORANGE & PINK
GREY & TURQUOISE
WHITE
VIOLET & BROWN
RED
BLACK
YELLOW
JUNCTION BOX
MODEL - JB720
POWER SUPPLY UNIT
MODEL - 1381LM
F 2A
THE RAYTEL GROUP LTD.
MULTICORE
CABLE
2 metres.
SECURE
AREA
Wiring Schematics
Wiring for K50 using a DC supply and DC Fail Safe release
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
11
9
8
7
DE S CRIP T ION
INIT IAL
IS S
1
DIGITAC
0
6
5
4
3
2
K50
ACCESS
1
FUNCTION
29 - 4 - 95
DA T E
+
-
TAMP
+
+
BATT
OUT
GREEN
BLUE
ORANGE & PINK
TITLE
GREY & TURQUOISE
WHITE
VIOLET & BROWN
RED
BLACK
YELLOW
JUNCTION BOX
MODEL - JB720
NC
COM
NO
TAMPER
EXIT
EXIT
CHECK E D
NC C NO
+ -
TAMPER ALARM OUTPUT
NORMALLY CLOSED LOOP
12 V BATTERY ESSENTIAL
FOR TIMEZONE OPERATION
29 - 4 - 95
DA T E
RGD 5006 / 19
A P P ROV E D
INTERFACE BOARD
MODEL - PC5006/1
DRAWING No.
BPM
DRA WN
MAINS SUPPLY
230 Vac 50 Hz.
TAMPER
TAMPER
+
12Vdc
13.8 V
L
E
N
OPERATION OF A K50 WITH
INTERFACE RELAY FOR FAIL
SAFE RELEASE.
POWER SUPPLY UNIT
MODEL - 1381LM
DOOR RELEASE
FAIL SAFE ( OPENED )
SECURE
AREA
F 2A
THE RAYTEL GROUP LTD.
MULTICORE
CABLE 2 metres.
ACCESS CONTROLLER
MODEL - K50
( VARIANTS K50S & K50B )
IS A FAIL SAFE DEVICE WHICH LOCKS WHEN
VOLTS ARE APPLIED. IT IS ESSENTIAL THAT
A BATTERY IS USED IN THIS APPLICATION.
CIRCUIT AUTOMATICALLY RESETS AS TAMPER
LOOP IS RE - ESTABLISHED.
THE TYPE OF RELEASE USED IN THIS CIRCUIT
TAMPER CLOSED LOOP IS INTERRUPTED.
IN THAT THE RELEASE WILL LOCK WHEN THE
THE CIRCUIT PROVIDES ADDITIONAL SECURITY
NOTE :
Wiring Schematics
Wiring for K50 Tamper Relay and DC Fail Safe release
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
12
9
8
7
DE SCRIPT ION
INIT IAL
ISS
1
DIGITAC
0
6
5
4
3
2
K50
A CCES S
1
FUNCT ION
ACCESS CONTROLLER
MODEL - K50
( VARIANTS K50S & K50B )
1 - 5 - 95
DAT E
JUNCTION BOX
MODEL - JB720
VIOLET & BROWN
NC
COM
-
EXIT
TAMPER
TAMPER
12Vdc
NO
+
13.8 V
EXIT
NC
+
C
-
CHE CK ED
NO
DRAWING No.
BPM
DRA WN
MAINS SUPPLY
230 Vac 50 Hz.
TAMPER
L
E
N
OPERATION OF A K50 WITH INTERFACE
RELAY FOR FAIL SECURE RELEASE.
TITLE
DOOR RELEASE
FAIL SECURE ( LOCKED )
GREEN
BLUE
ORANGE & PINK
GREY & TURQUOISE
WHITE
TAMP
+
BATT +
OUT
POWER SUPPLY UNIT
MODEL - 1381LM
RED
BLACK
YELLOW
SECURE
AREA
F 2A
THE RAYTEL GROUP LTD.
CABLE 2 metres.
MULTICORE
THE CIRCUIT PROVIDES ADDITIONAL SECURITY
IN THAT THE RELEASE WILL REMAIN LOCKED WHEN
THE TAMPER CLOSED LOOP IS INTERRUPTED.
THE TYPE OF RELEASE USED IN THIS CIRCUIT IS A
FAIL SECURE DEVICE WHICH UNLOCKS WHEN VOLTS
ARE APPLIED. IT IS ESSENTIAL THAT A BATTERY IS
USED IN THIS APPLICATION.
MOMENTARILY CLOSING THE RESET PUSHBUTTON
RESETS THE CIRCUIT AFTER TAMPER LOOP HAS
BEEN RE - ESTABLISHED.
NOTE :
1 - 5 - 95
DAT E
RGD 5006 / 20
APP RO VE D
RESET PUSHBUTTON
INTERFACE BOARD
MODEL - PC5006/1
TAMPER ALARM OUTPUT
NORMALLY CLOSED LOOP
12 V BATTERY ESSENTIAL
FOR TIMEZONE OPERATION
Wiring Schematics
Wiring for K50 Tamper Relay and DC Fail Secure release
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
13
1
ISS
WIRES
CONNECT
KEY
INITIAL
DESCRIPTION
PUSH BUTTON
WIRES
CROSS
CALL WIRES
CALL
PUSH
BUTTONS
K50 PCB
12 3 4 56
06-01-96
DATE
ENTRANCE PANEL MODEL KA1 - KA3
SPEECH UNIT
ART 930\832
RED
GREY &
T URQUOS E
G REE N
B LUE
NO
NC
COM
12V
B LA CK
V IO L ET &
B RO WN
ORA NG E &
PINK
240
SYSTEMS LTD.
RAYTEL SECURITY
0
PUSH TO
OPTIONAL EXIT BUTTON
(N\O OUTPUT)
EXIT
+
15V AC
7
4
B 12 3 56
HANDSET 900/000
7
4
B 12 356
HANDSET 900/000
7
4
B 1 2 35 6
HANDSET 900/000
PI-002-01
CHECKED APPROVED DATE
06-02-96
DRAWING No.
DRAWN
K.H.
INTERFACE RELAY
PC5006/1
NO
C
NC
JUNCTION BOX
MODEL - JB720
TITLE
GENERAL WIRING DIAGRAM FOR
KA1-KA3 SYSTEM.
WITH AC POWER SUPPLY AND
FAIL SECURE RELEASE
EXIT
EXIT
0V
POWER SUPPLY
ART 832/000
0
12
12V AC DOOR RELEASE
FAIL SECURE (LOCKED)
240V AC
50Hz
Wiring Schematics
Wiring for KA1-KA3 and AC Fail Secure release
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
14
1
ISS
KEY
WIRES
CONNECT
INITIAL
DESCRIPT ION
PUSH BUTTON
WIRES
CROSS
CALL WIRES
CALL
PUSH
BUTTONS
K50 PCB
1 2 3 4 5 6
SPEECH UNIT
ART 930\832
27-11-98
DAT E
ENTRANCE PANEL MODEL KA1 - KA3
ORANGE &
PINK
240
0
RED
0
NO
EXIT
12V 0V
COM
EXIT
NC
BLACK
12
POWER SUPPLY
ART 832/000
15V AC
+
TITLE
GENERAL WIRING DIAGRAM FOR
KA1-KA3 SYSTEM.
FITTED TO AN ELVOX AUTOMATIC
GATE SYSTEM
INTERFACE RELAY
PC5006/1
NO
C
NC
JUNCTION BOX
MODEL - JB720
- 33 12V DC INPUT
FROM ELVOX GATE
32
+ CONTROL BOX
POWER SUPPLY
17 18
TO ELVOX GATE CONTROL
BOX. TO INITIATE THE GATE
OPEN / CLOSE COMMAND
GREY &
T URQUOSE
GREEN
BL UE
VIOL ET &
BROWN
RAYTEL SECURITY
SYSTEMS LTD.
240V AC
50Hz
CHECKED
DRAWING No.
K.H.
DRAWN
DAT E
27 -11 -98
PI-002-01E
APPROVED
7
4
B 1 2 3 5 6
HANDSET 900/000
7
4
B 1 2 3 5 6
HANDSET 900/000
7
4
B 1 2 3 5 6
HANDSET 900/000
Wiring Schematics
Wiring for KA1-KA3 and Elvox Gate System
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
15
1
IS S
WIRES
CROSS
WIRES
CONNECT
INITIAL
DE S CRIP T IO N
PUSH BUTTON
CALL WIRES
KEY
CALL
PUSH
BUTTONS
K50 PCB
1 2 3 4 5 6
SPEECH UNIT
ART 930\832
06-01-96
DA T E
ENTRANCE PANEL MODEL KA1 - KA3
240
0
O RA NGE &
P INK
G RE Y &
T URQ UO S E
G RE EN
B L UE
EXIT
EXIT
0V
240V AC
50Hz
0
NO
C
NC
12
+
15V AC
0
PUSH TO
INTERFACE RELAY
PC5006/1
JUNCTION BOX
MODEL - JB720
EXIT
240
DC POWER SUPPLY
MODEL 1381LM
TITLE
GENERAL WIRING DIAGRAM FOR
KA1-KA3 SYSTEM.
WITH DC FAIL SAFE RELEASE
OPTIONAL EXIT BUTTON
(N\O OUTPUT)
NOTE
FAIL SAFE LOCKS CONNECT
0V AND NC AS SHOWN
FOR USE WITH FAIL SECURE LOCKS
CONNECT LOCK TO 0V AND NO
NO
NC
12V
COM
B LA CK
RE D
VIO L ET &
BRO WN
0
12V DC DOOR RELEASE
FAIL SAFE (UNLOCKED)
12
POWER SUPPLY
ART 832/000
RAYTEL SECURITY
SYSTEMS LTD.
240V AC
50Hz
CHE CKE D
DRAWING No.
K .H.
DRAWN
DA T E
0 6 -0 2-9 6
PI-002-02
AP P ROV E D
7
4
B 1 2 3 5 6
HANDSET 900/000
7
4
B 1 2 3 5 6
HANDSET 900/000
7
4
B 1 2 3 5 6
HANDSET 900/000
Wiring Schematics
Wiring for KA1 – KA3 with DC Fail Safe release
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
16
A
ISS
INIT IAL
DESCRIPT ION
DAT E
22-05-96
CABLE ART 2/063
12V
NO
NC
COM
RAYTEL SECURITY
SYSTEMS LTD.
12V AC DOOR RELEASE
FAIL SECURE (LOCKED)
ORANGE &
PINK
GREY &
T URQUOSE
GREEN
BLUE
VIOLET &
BROWN
BLACK
RED
EXIT
PUSH TO
JUNCTION BOX
MODEL - JB720
0
NOTE *
CONNECT 75-OHM RESISTOR
BETWEEN M AND V2
MONITOR ART 5479/01M
0
240V AC
50Hz
ENSURE PSU ART 832/030 IS
LOCATED AS CLOSE TO THE
MONITOR AS POSSIBLE
NO
NC
12V
COM
EXIT
EXIT
0V
CHECKED
DRAWING No.
K.H.
DRAWN
PI-007-01
APPROVED
PUSH
AND INTERFACE RELAY
22-05-96
DAT E
12V DC
DOOR RELEASE
+
JUNCTION BOX
MODEL - JB720
FOR FAIL SECURE LOCKS (LOCKED)
CONNECT T O NO CONT ACT
FOR FAIL SAFE LOCKS (OPEN)
CONNECT T O NC CONT ACT
FROM EXIT
VIOLET &
BROWN
GREY &
T URQUOSE
GREEN
BLUE
ORANGE &
PINK
RED
BLACK
VARIANT FOR OPERATION OF DC LOCKS
FROM EXTERNAL 12V DC PSU
(eg MODEL 138ILM)
240
POWER SUPPLY
ART 832/030
12
1
2
RED
3
4
5
6
7
8
9
10
11
12
V1
V2
M* 75 OHM
YELLOW
FROM K50
GENERAL WIRING DIAGRAM
FOR KV1 SYSTEM
TITLE
OPTIONAL EXIT BUTTON
(N\O OUTPUT)
EXIT
EXIT
0V
SUPPLIED CABLE IS FOR RUNS UP TO 30m
FOR CABLE RUNS UP TO 100m
USE COAXIAL CABLE TYPE RG59 AND
CABLE OF 1mm CSA.
K50 CABLE
15V AC
NO
C
+
NC
INTERFACE RELAY
PC5006/1
CALL
PUSH
BUTTON
K50 PCB
YELLOW
RED
COAX
7 6 5 4 3 2 1V M
CAMERA UNIT
5479/01T
ENTRANCE PANEL MODEL KV1
Wiring Schematics
Wiring for KV1 System and AC Fail Secure release
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
17
1
ISS
INITIAL
DESCRIPTION
K50 PCB
CALL
PUSH
BUTTONS
3 4 6 7 8 - +TV M
CAMERA UNIT
554/H50
ENTRANCE PANEL MODEL KV1
DATE
22-05-96
VIOLET &
BROWN
GREY &
TURQUOSE
GREEN
BLUE
12V DC DOOR RELEASE
FAIL SECURE (LOCKED)
ORANGE &
PINK
NO
EXIT
PUSH TO
NO
C
NC
+
15V AC
INTERFACE RELAY
PC5006/1
JUNCTION BOX
MODEL - JB720
6 7 8 - +T AM15 0 S1 C1
OPTIONAL EXIT BUTTON
(N\O OUTPUT)
CHECKED
DRAWING No.
K.H.
DRAWN
8 123 569 V
MONITOR CABLE RISER
GENERAL WIRING DIAGRAM
FOR KV5680 1, 2 & 3 KITS
TITLE
EXIT
15V 0V
COM
EXIT
NC
RAYTEL SECURITY
SYSTEMS LTD.
FOR AC LOCK OPERATION
SEE VARIANT FOR DC LOCKS
ON DRAWING PI-007-01
K50 CABLE
C1C2 1 2 3 - + S
BLACK
RED
M1V1V2 M2
PSU ART 5680
ENSURE A-B SWITCH IS
PRI IN THE A POSITION
A
ENSURE LOCK TIME (P3)
IS SET TO MINIMUM
B
240V AC
V1
M
V2
MONITOR ART 5601/000
MONITOR ART 5601/000
21-01-97
DATE
RGD 5013 / 65
APPROVED
CONNECT 75 OHM RESISTOR
TO THE LAST MONITOR
BETWEEN TERMINALS V2-M
V1
M
V2
1
2
3
4
5
6
7
8
9
10
11
12
V1
M
V2
1
2
3
4
5
6
7
8
9
10
11
12
Wiring Schematics
Wiring for KV1 – KV3 and AC Fail Secure release
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
18
Quick Programming Guide
Quick Programming Guide.
The K50 is programmed using the keyboard. Entering the six digit Master
code accesses the programming mode. The following paragraphs cover initial
programming for a basic access control system. To access the more advanced
features of the K50 please refer to the Advanced Programming Guide section.
Programming a code
When the K50 is delivered there are no user codes in memory. The following
instructions show how to enter a single user code for standard twenty-four
hour operation.
Action
Indication
Notes
Enter six Digit
Master Code
Press the # key
Press the # key
Red LED lights accompanied by a
long audible tone
Red LED begins to flash every ½
second
Enter a user code
Press the # key
Press the # key
Red LED begins to flash every
second
Red LED steady, long audible tone,
Red LED turns off
Found on the inside cover of
this manual
Master code accepted
Ready to accept a user code
Code can be four to eight
digits in length
The code has been accepted
Exit function and return to
normal operation
Ensure that there is less than four seconds delay between each key press. This
prevents the Code Entry Timer from registering an invalid code.
Deleting a code
The following instructions show how to delete a single user code.
Action
Indication
Notes
Enter six Digit
Master Code
Press the # key
Press 9 followed
by the # key
Enter the user
code to delete
followed by the #
key
Press the # key
Press the * key
Red LED lights accompanied by a
long audible tone
Red LED begins to flash every ½
second
Red LED begins to flash every
second
Two long audible tones Red LED
off while tone sounds.
Red LED steady, long audible tone,
Red LED turns off
Found on the inside cover of
this manual
Master code accepted
Delete function entered
If the code does not exist the
K50 gives a two-second
audible tone with steady red
LED.
The code has been deleted.
Note: To escape without
deleting the code press the *
key instead of the # key. The
K50 will give a two-second
audible tone with steady red
LED.
Exit function and return to
normal operation
Ensure that there is less than four seconds delay between each key press. This
prevents the Code Entry Timer from registering an invalid code.
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
19
Quick Programming Guide
Setting the Lock Relay Time
The lock relay can be set to operate from one to ninety nine seconds when a
valid user code is entered or the exit push button is operated. The factory
setting for the relay time is four seconds. The following instructions show
how to adjust this time if required.
Action
Indication
Notes
Enter six Digit
Master Code
Press the # key
Press 1 followed
by the # key
Enter the required
lock time
(1 – 99 seconds)
followed by the #
key
Press the # key
Press the * key
Red LED lights accompanied by a
long audible tone
Red LED begins to flash every ½
second
Relay operates for the number of
seconds entered accompanied by
the Red LED and Green LED lit
and an audible tone
Two long audible tones Red LED
off while tone sounds.
Red LED steady, long audible tone,
Red LED turns off
Found on the inside cover of
this manual
Master code accepted
Set relay time function entered
Should the relay time require
adjusting enter the new lock
time before proceeding to the
next step. This can be
repeated as often as required.
The lock time has been set
Exit function and return to
normal operation
Ensure that there is less than four seconds delay between each key press. This
prevents the Code Entry Timer from registering an invalid code.
Activating the K50 self test mode
The K50 can test the internal functions and the operation of each button on the
keypad by entering the self-test mode.
Action
Indication
Notes
Turn off the
power to the K50
Hold down the
# and * keys
Return power to
the K50
After the fifth
bleep Release the
# and * keys
The Red and Green LED’s will
flash accompanied by an audible
bleep.
The unit commences the self-test.
See K50 test sequence for details of
test results.
Ensure the # and * keys
remain held down
Releasing the keys before the
fifth bleep exits to normal
mode.
Releasing the keys between
the fifth and ninth bleep enters
self-test mode.
WARNING: If the keys are
not released before the tenth
bleep the K50 will enter
Master Reset this will clear all
the programmed codes.
See the Advanced
Programming section for
details.
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
20
Quick Programming Guide
K50 Test sequence
After entering Self-test the K50 will run through the following sequence of
tests.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
Red LED flashes twice.
Green LED flashes twice.
Sounder bleeps twice.
Lock Relay operates twice.
The K50 tests internal functions. Should a fault be detected the test
sequence will end and the Red and Green LED’s will flash. If no faults
are found the Red and Green LED will illuminate accompanied by a
single audible tone.
The K50 is now ready to test the keypad. Press each keypad button in
turn.
Press button 1 both LED’s will flash once accompanied by an audible
tone to indicate the button is functioning correctly.
Press button 2 both LED’s will flash twice accompanied by an audible
tone to indicate the button is functioning correctly.
Press buttons 3 to 9 both LED’s will flash, for the number of times
corresponding to the button pressed, accompanied by an audible tone
to indicate the button is functioning correctly.
Press button 0 both LED’s will flash ten times accompanied by an
audible tone to indicate the button is functioning correctly.
Press button * both LED’s will flash eleven times accompanied by an
audible tone to indicate the button is functioning correctly.
Press the exit button both LED’s will flash twelve times accompanied
by an audible tone to indicate the button is functioning correctly.
Press button # both LED’s will give three long flashes accompanied by
an audible tone. The unit then returns to normal mode.
A self-test can be performed at any time without affecting any programmed
settings. Care should be taken however to ensure a Master reset is not
performed, as this would clear all pre programmed settings.
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
21
Advanced Programming Guide
Advanced Programming Guide.
Performing a Master Reset
The Master Reset will perform the following tasks: Clear all user codes.
Reinstate the Factory master code.
Clear all time zone functions and settings
Reset sounder operation
Reset relay time to four seconds
Action
Turn off the
power to the K50
Hold down the
# and * keys
Return power to
the K50
After the tenth
bleep Release the
# and * keys
Indication
Notes
The Red and Green LED’s will
flash accompanied by an audible
bleep.
The unit performs a Master Reset.
Ensure the # and * keys
remain held down
Releasing the keys before the
fifth bleep exits to normal
mode.
Releasing the keys between
the fifth and ninth bleep enters
self-test mode. See previous
section for details.
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
22
Advanced Programming Guide
Setting the Lock Relay Time
The lock relay can be programmed to operate from one to ninety nine seconds
when a valid user code is entered or the exit push button is operated.
When the K50 is supplied the lock relay time is set at four seconds.
To program the Lock Relay Time
Action
Indication
Notes
Enter six Digit
Found on the inside cover of
Master Code
this manual
Press the # key
Red LED lights accompanied by a
Master code accepted
long audible tone
Press 1 followed
Red LED begins to flash every ½
Set relay time function entered
by the # key
second
Enter the required Relay operates for the number of
Should the relay time require
lock time
seconds entered accompanied by
adjusting enter the new lock
(1 – 99 seconds)
the Red LED and Green LED lit
time before proceeding to the
followed by the # and an audible tone
next step. This can be
key
repeated as often as required.
Press the # key
Two long audible tones Red LED
The lock time has been set
off while tone sounds.
Press the * key
Red LED steady, long audible tone, Exit function and return to
Red LED turns off
normal operation
Ensure that there is less than four seconds delay between each key press. This
prevents the Code Entry Timer from registering an invalid code.
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
23
Advanced Programming Guide
Installing User Codes
The K50 can be programmed with a maximum of fifty user codes of four to
eight digits in length. These user codes can be programmed to operate in
twenty four hour mode, assigned to one of the five timed access periods,
service mode or latch mode.
User codes assigned to access periods 1 to 5 will not function until the clock
and time periods have been set. (See Setting the clock, page 25, and
Programming time zones, page 30, for details of how to do this.)
User codes assigned to access period 6 are used to enter Service Mode. User
codes assigned to access period 7 are used to enter Latch Mode.
When the K50 is delivered there are no user codes in memory.
Note: If the first four digits of the code being entered is the same as an existing
code then the new code will overwrite the existing code.
Action
Enter six Digit
Master Code
Press the # key
Press 2 followed
by the # key
Enter the User
Code
Press the # key
Press the # key
for 24 hour
operation
Or
For Timed
operation press
key 1-7 followed
by the # key
To add additional
codes repeat
instructions from
highlighted
section inclusive.
OR
Press the * key to
exit programming
mode.
To Install Codes
Indication
Red LED lights accompanied by a
long audible tone
Red LED begins to flash every ½
second
Red LED flashes every second
Red LED flashes twice
accompanied by a long audible tone
Notes
Found on the inside cover of
this manual
Master code accepted
Ready to install code
Code can be four to eight
digits in length
The code has been accepted
1 to 5 are timed access periods
See Programming time
zones, page 30, for details.
6 is service mode, see page 26
for details of use.
Red LED steady, long audible tone,
Red LED turns off
7 is latch mode, see page 27
for details of use.
Exit function and return to
normal operation
Ensure that there is less than four seconds delay between each key press. This
prevents the Code Entry Timer from registering an invalid code.
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
24
Advanced Programming Guide
Setting the Clock
The clock must be set to enable the time zone facility. (See Programming time
zones, page 30 and Installing a user code, page 24 for details of how to set
time zones and assign user codes.)
When the K50 is delivered the clock is disabled (set to 00hr 00min). After
programming, should it be desirable, the clock can be disabled by setting the
clock time to 00hr 00min, this has the effect of stopping the clock and
disabling all time zone operations.
Note: The K50 clock is not battery backed. If time zone operation is to
be maintained in the event of mains failure a 12V DC supply with a
battery standby facility should be used.
If a power failure occurs after the clock has been set, when the power is restored
the K50 will bleep three times to indicate the time may require resetting. This
will be repeated every minute until the time is reprogrammed or the clock
function is disabled by setting the clock time to 00hr 00min.
Action
Enter six Digit
Master Code
Press the # key
Press 3 followed
by the # key
Enter the correct
time
Press the # key
Press the # key
Press the * key
To Set the Time
Indication
Red LED lights accompanied by a
long audible tone
Red LED begins to flash every ½
second
Red LED flashes every second
Red LED flashes twice
accompanied by a long audible tone
Red LED steady, long audible tone,
Red LED turns off
Notes
Found on the inside cover of
this manual
Master code accepted
Ready to Set the time
Time is to be entered using
24hr format. E.g. 9.30 AM
would be entered 0930 while
9.30 PM would be entered
2130.
The time has been accepted
The time has been set
Exit function and return to
normal operation
Ensure that there is less than four seconds delay between each key press. This
prevents the Code Entry Timer from registering an invalid code.
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
25
Advanced Programming Guide
Setting Service Mode
When the K50 is in service mode, pressing any button on the keypad will
operate the lock output relay for the pre-set lock time. Service mode can be
activated by entering a user code that has been assigned to access period 6 (see
Installing a User Code, page 24), manually entered or set to operate
automatically by allocating to an access period.
When the K50 is delivered, service mode is disabled.
Note: Service mode and Latch mode cannot be programmed to the same
access period at the same time. When Service or Latch mode is assigned to an
access period it overwrites any previously installed mode.
Action
Enter six Digit
Master Code
Press the # key
Press 4 followed
by the # key
Press the # key
To Enter Service Mode Manually
Indication
Notes
Red LED lights accompanied by a
long audible tone
Red LED begins to flash every ½
second
Red LED flashes off twice
accompanied by two long tones and
green LED turns on for one second.
Found on the inside cover of
this manual
Master code accepted
Ready to enter service mode
The K50 exits programming
mode and enters Service
Mode.
To exit Service mode
Press and hold the * and # keys together, the red LED will flash accompanied
by a short tone, the relay will operate for the pre-set time. The keys should not
be released until the relay time ends. Note: This will disable all programmed
timed service operations and therefore should not be used to reset a timed operation.
Action
Enter six Digit
Master Code
Press the # key
Press 4 followed
by the # key
Enter the access
period number
(0 – 5) followed
by the # key
Press the # key
Press the * key
To Set Service Mode for timed operation
Indication
Notes
Red LED lights accompanied by a
long audible tone
Red LED begins to flash every ½
second
Red LED flashes every second
Red LED flashes twice
accompanied by a long audible tone
Red LED steady, long audible tone,
Red LED turns off
Found on the inside cover of
this manual
Master code accepted
Ready to enter service mode
Service mode has been
allocated. Note: access period
0 is used to disable all
programmed timed service
operations
Service mode has been set
Exit function and return to
normal operation
Ensure that there is less than four seconds delay between each key press. This
prevents the Code Entry Timer from registering an invalid code.
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
26
Advanced Programming Guide
Setting Latch Mode
Latch mode is used to latch the lock output relay on. Latch mode can be
activated by entering a user code that has been assigned to access period 7 (see
Installing a User Code, page 24), manually entered or set to operate
automatically by allocating to an access period.
When the K50 is delivered latch mode is disabled.
Note1: The exit push button is disabled during latch mode operation.
Note2: Latch mode and Service mode cannot be programmed to the same
access period at the same time. When Latch or Service mode is assigned to an
access period it overwrites any previously installed mode.
To Enter Latch Mode Manually
Action
Indication
Enter six Digit
Master Code
Press the # key
Press 5 followed
by the # key
Press the # key
Press the * key
Red LED lights accompanied by a
long audible tone
Red LED begins to flash every ½
second
Red LED flashes off twice with two
long tones and the green LED turns
on during relay operation.
Red LED steady, long audible tone,
Red LED turns off
Notes
Found on the inside cover of
this manual
Master code accepted
Ready to enter latch mode
The K50 exits programming
mode and enters latch Mode.
Exit function and return to
normal operation
To exit Latch mode
Press the # key or enter a valid user code.
Note: Using the # key to exit will disable all programmed timed latch operations
and therefore should not be used to reset a timed operation. When a user code is used
the sounder and green LED will operate for the pre-set relay time before exiting.
To Set Latch Mode for timed operation
Action
Enter six Digit
Master Code
Press the # key
Press 5 followed
by the # key
Enter the access
period number
(0 – 5) followed
by the # key
Press the # key
Press the * key
Indication
Red LED lights accompanied by a
long audible tone
Red LED begins to flash every ½
second
Red LED flashes every second
Red LED flashes twice
accompanied by a long audible tone
Red LED steady, long audible tone,
Red LED turns off
Notes
Found on the inside cover of
this manual
Master code accepted
Ready to enter latch mode
Latch mode has been set.
Note: access period 0 is used
to disable all programmed
timed latch operations
Latch mode has been set
Exit function and return to
normal operation
Ensure that there is less than four seconds delay between each key press. This
prevents the Code Entry Timer from registering an invalid code.
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
27
Advanced Programming Guide
Setting Sounder operation
The Sounder is used to give audible indication of key presses and lock relay
activation. Should it be required the sounder can be disabled, or, for systems
incorporating a long relay activation, the sounder can be programmed with a
reduced ON time.
When the K50 is delivered the sounder time will equal the relay time and will
bleep with each key press.
The sounder can be programmed to operate for 1 to 99 seconds during relay
operation. Note: The sounder cannot be programmed to operate for longer
than the relay time.
Action
Enter six Digit
Master Code
Press the # key
Press 6 followed
by the # key
Press the # key to
Mute sounder
OR
The number of
seconds required
(1 – 99) followed
by the # key
Press the # key
Press the * key
To Mute / Set Sounder
Indication
Red LED lights accompanied by a
long audible tone
Red LED begins to flash every ½
second
Red LED flashes every second
Red LED flashes twice
accompanied by a long audible tone
Red LED steady, long audible tone,
Red LED turns off
Notes
Found on the inside cover of
this manual
Master code accepted
Ready to mute / set sounder
The setting has been accepted
The time has been set
Exit function and return to
normal operation
Ensure that there is less than four seconds delay between each key press. This
prevents the Code Entry Timer from registering an invalid code.
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
28
Advanced Programming Guide
Code Capacity Check
This function is used to check the number of User Codes programmed into the
K50. When initiated the K50 will give a short audible tone for each User
Code programmed.
Action
Enter six Digit
Master Code
Press the # key
Press 7 followed
by the # key
Press the # key
when ready to
count.
Press the * key
Code Capacity Check
Indication
Red LED lights accompanied by a
long audible tone
Red LED begins to flash every ½
second
Red LED flashes accompanied by a
short tone for each User Code
programmed in the K50.
Red LED flashes twice
accompanied by a long audible tone
Red LED steady, long audible tone,
Red LED turns off
Notes
Found on the inside cover of
this manual
Master code accepted
Code capacity check entered
Each tone indicates one
programmed code.
Indicates that no more user
codes remain to be counted.
Exit function and return to
normal operation
Ensure that there is less than four seconds delay between each key press. This
prevents the Code Entry Timer from registering an invalid code.
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
29
Advanced Programming Guide
Access Levels and Time Zones
Up to two sets of time zone markers (Start1, End1 – Start2, End2) may be
programmed into the controller to give a maximum of six separate access
levels covering six specific time zones during a 24 hour period. This allows
different codes to be assigned to any one of the six time zones. The method
for assigning access levels to codes can be found under ”Installing User
Codes” on page 24.
The following table shows the way in which the time zone markers are used to
create the six different access levels.
00.00
hrs
Access
Level 0
24.00
Start1
No markers
Default Setting
Level 2
Access
Zone 2
active
Access Zone 2 active
Access
Zone 3
active
Access Zone 4 active
Level 4
Level 5
Markers
Start1 – End2
hrs
End2
Access
Zone 1
active
Level 3
Markers
Start2 – End2
Start2
Access Zone 0 Active, Unlimited Access
Level 1
Markers
Start1 – End1
End1
Access
Zone 4
active
Access Zone 5 active
Level 0
does not require any time zone markers to be set and is the
default setting for all codes. Codes assigned to this level will
have unlimited access during the 24 hour period. (Zone 0).
Level 1
is the time zone commencing Start1 and ending with End1, any
codes assigned to level 1 will only have access during this
period. (Zone 1).
Level 2
is the time zone commencing End1 and ending with Start1, any
codes assigned to level 2 will only have access during this
period. (Zone 2).
Level 3
is the time zone commencing Start2 and ending with End2, any
codes assigned to level 3 will only have access during this
period. (Zone 3).
Level 4
is the time zone commencing End2 and ending with Start2, any
codes assigned to level 4 will only have access during this
period. (Zone 4).
is the time zone commencing Start1 and ending with End2, any
codes assigned to level 5 will only have access during this
period. (Zone 5).
Level 5
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
30
Advanced Programming Guide
It should be noted that once time zone markers have been set for one level,
they remain fixed in those positions for the other levels.
For user codes assigned to access periods to operate correctly the unit clock
must be set. Refer to setting the clock, page 25 for details on setting the
correct time. By setting time zone markers Start1 and End1, access levels 1
and 2 are available for use. Access levels 3, 4 and 5 will not be available until
time zone markers Start2 and End2 have been programmed.
Programming Time Zone markers
Action
Enter six Digit
Master Code
Press the # key
Indication
Red LED lights accompanied by a
long audible tone
Red LED begins to flash every ½
second
Red LED flashes every second
Notes
Found on the inside cover of
this manual
Master code accepted
Press 8 followed
Ready to program time zones
by the # key
Enter time zone 1
Start time has been accepted
start time (Start1)
in 24 hour format
followed by the #
key. ( E.g. 0900#
for 9 AM)
Enter time zone 1 Red LED flashes every 1½ second
Stop time has been accepted
stop time (End1)
in 24 hour format
followed by the #
key. ( E.g. 1130#
for 11.30 AM)
Skip the next two operations if time zone 2 is not required
Enter time zone 2 Red LED flashes every 2 seconds
Start time has been accepted
start time (Start2)
in 24 hour format
followed by the #
key. ( E.g. 1600#
for 4.00 PM)
Enter time zone 2 Red LED flashes every 2½ seconds Stop time has been accepted
stop time (End2)
in 24 hour format
followed by the #
key. ( E.g. 1830#
for 6.30 PM)
Press the # key
Red LED flashes twice
The time zones have been set
accompanied by a long audible tone
Press the * key
Red LED steady, long audible tone, Exit function and return to
Red LED turns off
normal operation
Ensure that there is less than four seconds delay between each key press. This
prevents the Code Entry Timer from registering an invalid code.
To deactivate time zones programme the start and stop times to 0000.
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
31
Advanced Programming Guide
Deleting a single user code
The following instructions show how to delete a single user code.
Note: The User Master Code cannot be deleted with this function.
Action
Enter six Digit
Master Code
Press the # key
Press 9 followed
by the # key
Enter the user
code to delete
followed by the #
key
Press the # key
Press the * key
Indication
Red LED lights accompanied by a
long audible tone
Red LED begins to flash every ½
second
Red LED begins to flash every
second
Two long audible tones Red LED
off while tone sounds.
Red LED steady, long audible tone,
Red LED turns off
Notes
Found on the inside cover of
this manual
Master code accepted
Delete function entered
If the code does not exist the
K50 gives a two-second
audible tone with steady red
LED.
The code has been deleted.
Note: To escape without
deleting the code press the *
key instead of the # key. The
K50 will give a two-second
audible tone with steady red
LED.
Exit function and return to
normal operation
Ensure that there is less than four seconds delay between each key press. This
prevents the Code Entry Timer from registering an invalid code.
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
32
Advanced Programming Guide
Deleting ALL user codes
This function will delete all user codes. All other programmed parameters and
the Master Code will not be affected.
Action
Enter six Digit
Master Code
Press the # key
Press 10 followed
by the # key
Press the # key
Press the * key
Indication
Red LED lights accompanied by a
long audible tone
Red LED begins to flash every ½
second
Two long audible tones Red LED
off while tone sounds.
Red LED steady, long audible tone,
Red LED turns off
Notes
Found on the inside cover of
this manual
Master code accepted
Delete function entered
Warning: This will delete all
programmed user codes.
Note: To escape without
deleting the code press the *
key instead of the # key. The
K50 will give a two-second
audible tone with steady red
LED.
Exit function and return to
normal operation
Ensure that there is less than four seconds delay between each key press. This
prevents the Code Entry Timer from registering an invalid code.
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
33
Advanced Programming Guide
Changing the Master Code
For increased security the Factory Master Code can be reprogrammed to a
User Master Code. The User Master Code can be reprogrammed as often as
required.
Note: A User Master Code cannot be programmed if its first four digits are
the same as a current User Code, this also means that a user code cannot be
programmed if its first four digits are the same as the current Master Code.
Please note there is no function 11.
Action
Indication
Notes
Enter six Digit
Master Code
Press the # key
Press 12 followed
by the # key
Enter the 6 digit
Master code
followed by the #
key.
Press the # key
Press the * key
Red LED lights accompanied by a
long audible tone
Red LED begins to flash every ½
second
Red LED begins to flash every
second
Two long audible tones Red LED
off while tone sounds.
Red LED steady, long audible tone,
Red LED turns off
Found on the inside cover of
this manual
Master code accepted
Ready to reprogram the Master
Code
The new Master Code has
been accepted.
The new Master Code has
been programmed.
Exit function and return to
normal operation
Ensure that there is less than four seconds delay between each key press. This
prevents the Code Entry Timer from registering an invalid code.
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
34
Technical Information
Technical Information
Power Supply
-
10 – 16V AC, 10 – 28V DC.
Power Consumption
-
9 mA quiescent, 80 mA during relay
operation.
Lock output
-
Volt free changeover. Contact rating
50V AC / DC 1.5A inductive.
Tamper Switch
-
Volt free normally open contact.
Exit Button
-
Requires normally open switch input.
Code Memory
-
Permanent retention in E2PROM.
Clock Memory
-
There is no internal battery. The clock
will require resetting if power is lost.
Power Failure
Indication
-
If the clock has been programmed the
K50 will emit three audible bleeps every
minute after power is restored. To turn
this off set the correct time or disable the
clock.
Connections
-
Unit is supplied with two metres of
twelve core cable.
Visual Indications
-
Red LED to indicate keypad entry and
programming status. Green LED to
indicate relay operation.
Dust/Water protection
-
IP54.
Dimensions (mm)
Model
H
W
D
K50
136 80
32
K50 S
146 86
K50 B
146 86
K50 C
146 86
30
K50CB
146 86
30
FB146 (for K50S/B) 135 75
35
SB146/1 (for K50S/B) 151 92
32
KA series (Audio entry panel with keypad)
KV series (Video entry panel with keypad)
Main Material
ABS housing UL 94-5v
Stainless Steel grade BS1449/304
Polished Brass grade BS2870/cz120
Stainless Steel grade BS1449/304
Polished Brass grade BS2870/cz120
Zinc Plated Steel, Flush box
Coated Steel / Paint finish, Surface box
Please contact the office for details
Please contact the office for details
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
35
Technical Information
Programming Summary Table
Steps 1
Description
Master
code
2
3
4
Function No.
1st Data
5
2nd Data
3rd Data
6
7
8
4th Data Confirm Escape
Enter Program Master code
#
mode
Single User
Code
Master code
#
#
User Code #
#
AUTO
Relay time
Master code
#
1#
Time(seconds)#
#
*
Install Codes
(24 hour)
Master code
#
2#
User Code #
#
*
Master code
Install Codes
#
(with time zone)
2#
User Code #
Set Clock
Master code
#
3#
Time (24Hr) #
#
*
Services Mode
Master code
#
4#
Time Zone #
#
*
Latch Mode
Master code
#
5#
Time Zone #
#
*
Sounder Time
Master code
#
6#
Time(seconds)#
#
*
Code Capacity
Master code
#
7#
#
*
Time Settings
(T1 and T2)
Master code
#
8#
Time 1 #
Time 2 #
#
*
Time Settings
(T1 to T4)
Master code
#
8#
Time 1 #
Time 2 #
#
*
Delete Codes
Master code
#
9#
Code to Delete
#
#
*
Delete All User
Codes
Master code
#
10#
#
*
Reprogram
Master code
Current
Master
Code #
12#
#
*
New 6 digit
Master Code #
*
Time Zone #
Time 3 #
Time 4 #
Escape Program
Mode
Southern Office
Raytel Security Systems Ltd.
Northern Office
Tel. 01268 775656 Fax. 01268 745001
Tel. 0141 3324232 Fax. 0141 3326952
36
*