Transcript
QUICK START PROGRAMMING Setting Single code operation Follow the steps below to program the K50 keypad for single code operation. 1) Enter the six digit master code, as found inside the front cover of the manual, then press the # button. 2) Press # button again. 3) Enter your four to eight digit user code then press the # button. 4) Press # button again. The LED’s should now be off and the keypad is ready to use. Deleting a Single code Follow the steps below to delete a single code from the K50 keypad. 1) Enter the six digit master code, as found inside the front cover of the manual, then press the # button. 2) Press 9 followed by the # button. 3) Enter your four to eight digit user code to delete then press the # button. 4) Press # button again. 5) Press * button The LED’s should now be off and the keypad is ready to use. For further programming options see over for the Programming Summary Table or for full programming instructions view the programming section starting on page 11 of manual. Enter Master code here for quick reference. Factory set master code : User set master code: RAYTEL SECURITY SYSTEMS LIMITED Access Control Keypad Table of Users and Keypad Parameters Installation Company: ………………………..………………. Tel: ……………………….…………… Date: ….………….…...… Name of On-Site Programmer(s): …………………………………………..………………………………………………….……………………..... Master Code FMC: …………………….………..…….……………...….…..…. UMC (If Set): …………..…..……..….…….……..…..…….……. Unit Type: ……….…..………..………………….….. Lock Time: .……..……..…Seconds Serial Number: .……………………....….…… Time Zone Periods: TZ1 from to (If Set) TZ2 from to TZ3 from to TZ4 from to TZ5 from to Latch Mode Time: No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 NAME from to Service Mode Time: CODE TIME ZONE from LATCH CODE to SERVICE CODE DATE 50 We recommend this page should be filled in and regularly updated and kept in a safe and secure location by the person responsible for the upkeep of the system. The Digitac K50 Access Control System Installation and User Manual Issue 2 – May 2001 IMPORTANT NOTE Please keep this manual in a safe place with the premises Key holder. The Factory Master Code is inside. Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 Factory Master Code The Factory Master Code allows access to the programming modes of the K50. It is recommended that this manual be kept in a safe place for future reference. Factory Master Code VERY IMPORTANT PLEASE KEEP SAFE Unit Serial Number If the Factory Master Code is reprogrammed the new User Master Code should be noted below. User Master Code Declaration of Conformity We, Raytel Security Systems Ltd, declare that the equipment referred to within this document, conforms to the European Commission Electromagnetic Compatibility (EMC) Directive (Directive 89/336/EEC) when installed in strict accordance with the guidelines contained within this document. Technical Support For all technical enquiries relating to this equipment, engineers are available at the following addresses: Rayleigh Office Glasgow Office Raytel House Brook Road Rayleigh Essex SS6 7XH Unit 3, Block 5 Oakbank Industrial Estate Garscube Road Glasgow G20 7LU Tel: Fax: Tel Fax (01268) 749310 (01268) 745001 (0141) 3324232 (0141) 3326952 Raytel Security reserves the right to change the content of this manual and product design without prior notice. Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 1 Index GENERAL DESCRIPTION..................................................................................................................4 OPERATION ..........................................................................................................................................4 AUDIBLE AND VISUAL INDICATIONS ....................................................................................................4 • Key press Confirmation. ...........................................................................................................4 • Valid Code. ...............................................................................................................................4 • Invalid Code .............................................................................................................................4 • Invalid Data..............................................................................................................................4 ADDITIONAL FEATURES ......................................................................................................................5 Code Entry Timer ............................................................................................................................5 Code Capacity ..................................................................................................................................5 Master Code .....................................................................................................................................5 Timed Code Operation.....................................................................................................................5 Tamper Switch .................................................................................................................................5 Timed Lock Operation.....................................................................................................................5 Exit Button.......................................................................................................................................5 Service Mode....................................................................................................................................5 Latch Mode ......................................................................................................................................6 Self Test............................................................................................................................................6 Master Reset.....................................................................................................................................6 INSTALLATION ...................................................................................................................................7 CONTROL UNIT ....................................................................................................................................7 SEALING ...............................................................................................................................................7 POWER SUPPLY ....................................................................................................................................7 ELECTRIC RELEASE.............................................................................................................................7 EXIT BUTTON .......................................................................................................................................7 CABLE COLOUR CODE.........................................................................................................................8 WIRING SCHEMATICS ......................................................................................................................9 WIRING FOR K50 USING AN AC SUPPLY WITH AN AC FAIL SECURE RELEASE .............................9 WIRING FOR K50 USING A DC SUPPLY AND DC FAIL SECURE RELEASE.........................................10 WIRING FOR K50 USING A DC SUPPLY AND DC FAIL SAFE RELEASE .............................................11 WIRING FOR K50 TAMPER RELAY AND DC FAIL SAFE RELEASE ...................................................12 WIRING FOR K50 TAMPER RELAY AND DC FAIL SECURE RELEASE ...............................................13 WIRING FOR KA1-KA3 AND AC FAIL SECURE RELEASE ................................................................14 WIRING FOR KA1-KA3 AND ELVOX GATE SYSTEM ........................................................................15 WIRING FOR KA1 – KA3 WITH DC FAIL SAFE RELEASE.................................................................16 WIRING FOR KV1 SYSTEM AND AC FAIL SECURE RELEASE ...........................................................17 WIRING FOR KV1 – KV3 AND AC FAIL SECURE RELEASE ..............................................................18 QUICK PROGRAMMING GUIDE. ..................................................................................................19 PROGRAMMING A CODE.....................................................................................................................19 DELETING A CODE..............................................................................................................................19 SETTING THE LOCK RELAY TIME .....................................................................................................20 ACTIVATING THE K50 SELF TEST MODE ...........................................................................................20 K50 Test sequence .........................................................................................................................21 ADVANCED PROGRAMMING GUIDE. .........................................................................................22 PERFORMING A MASTER RESET .......................................................................................................22 SETTING THE LOCK RELAY TIME .....................................................................................................23 INSTALLING USER CODES..................................................................................................................24 SETTING THE CLOCK .........................................................................................................................25 SETTING SERVICE MODE...................................................................................................................26 To Enter Service Mode Manually .................................................................................................26 To exit Service mode......................................................................................................................26 To Set Service Mode for timed operation......................................................................................26 Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 2 Index SETTING LATCH MODE .....................................................................................................................27 To Enter Latch Mode Manually....................................................................................................27 To exit Latch mode ........................................................................................................................27 To Set Latch Mode for timed operation ........................................................................................27 SETTING SOUNDER OPERATION.........................................................................................................28 CODE CAPACITY CHECK ...................................................................................................................29 ACCESS LEVELS AND TIME ZONES ...................................................................................................30 Programming Time Zone settings.................................................................................................31 DELETING A SINGLE USER CODE .......................................................................................................32 DELETING ALL USER CODES.............................................................................................................33 CHANGING THE MASTER CODE ........................................................................................................34 TECHNICAL INFORMATION .........................................................................................................35 PROGRAMMING SUMMARY TABLE ...........................................................................................36 Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 3 General Description General Description The K50 is a compact self-contained access control unit, (which may also be incorporated into audio and video entrance panels), designed for single door operation. Installation is quick and simple, with all programming done via the keypad. Typical K50 Installation Open Area Secure Area Power Supply Mains Operation K50 A person wishing to gain access to the secure area will enter their user code via Electric the keypad. If the correct code has been Release Exit entered the lock output relay will operate Push for the pre-set time. If the code entered is incorrect, subsequent key presses will be ignored for six seconds, the last two seconds of which will be accompanied by a continuous error tone. This makes code breaking by trial and error more difficult. Audible and visual indications During normal operation of the K50 the following audible / visual responses will be encountered. • Key press Confirmation. When a button is pressed, except the *, the K50 will respond with a short tone accompanied by the RED LED flashing on / off. • Valid Code. When a valid user code is entered or the exit button is operated the output relay will operate for a pre-set time. A tone and illumination of the GREEN LED accompany this. This will continue while the output relay is in operation. • Invalid Code If an invalid code is entered the K50 waits four seconds before sounding a low frequency tone; this is accompanied by the illumination of the RED LED. This error tone lasts for two seconds. During program mode in addition to the Key press Confirmation and the indications as detailed in the individual programming tables the following audible / visual response may be encountered. • Invalid Data. If invalid data is entered e.g. trying to add a user code that already exists the K50 will emit a low frequency tone; this is accompanied by the illumination of the RED LED. This error tone lasts for two seconds. Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 4 General Description Additional Features Code Entry Timer A delay of more than four seconds between successive key presses will register as an incorrect code, subsequent key presses will be ignored for six seconds, the last two seconds of which will be accompanied by a continuous error tone. Code Capacity The K50 has the capacity to store up to fifty access codes of four to eight digits. The codes are stored in EPROM and therefore will be retained even if the power is removed. Master Code The Master code is used to access all the programming features. Each unit is factory programmed with its own unique master code. This code can be found on the inside cover of this manual. For additional security it is possible to reprogram the master code. The new code should be noted in the space provided inside the front cover of this manual, which should then be kept in a restricted, secure location. Timed Code Operation During normal operation, entering a valid code at any time will activate the door release. Optionally up to two sets of time zone markers may be programmed into the controller giving six access periods. This allows different codes to be assigned to different security levels. Please refer to the section on Access Levels and Time Zones starting on page 30 of this manual. Tamper Switch When the unit is installed the tamper switch lever is depressed by contact against the mounting surface. This makes a short circuit between the two tamper alarm cables (yellow and white cables in multicore). If the unit is removed, the tamper switch opens breaking the circuit between the two tamper alarm cables. This change in state may be used to operate a remote alarm if required. Timed Lock Operation The lock output relay operation time is adjustable between one and ninety nine seconds in one-second increments. Exit Button A normally open push button may be fitted to give lock operation from within the secure area. Service Mode During service mode operation, pressing any button on the keypad will operate the lock output relay for the pre-set lock time. This option is designed for use with fail secure releases. Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 5 General Description Latch Mode Latch mode is used to latch the lock output relay on. This can be done manually, using the master code to turn latch mode on or off or, programmed to automatically operate during certain access periods. This option is only recommended for use with fail safe door releases. Self Test The unit has a self-diagnostic mode. When entered it allows the controller and keypad functions to be tested with audible and visual confirmation of the results. Master Reset The master reset will clear all user codes and reset all functions to their factory defaults, including the factory user code. Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 6 Installation Installation Control Unit The control unit should be securely attached to a wall adjacent to the entrance that it controls. Care should be taken to establish that the wall upon which the unit is to be mounted is of sufficient size and construction to meet the dimensions and weight of the control unit. If any risk of flooding or free flowing water is apparent, the control unit should be fitted in a position that will provide adequate protection from the ingress of moisture. The control unit should be mounted at such a height, approximately 1.3 meters, 1.5 meters for integrated audio / video panels, that it can be used without undue difficulty. Sealing Ensure the unit is adequately sealed, using a flexible sealing compound, to prevent moisture ingress. The unit should be sealed on the top, left and right edges, the bottom edge should be left unsealed to allow for drainage and ventilation. For flush installations, ensure that the front edge of the flush box is installed level with the mounting surface such that when the front panel is fitted, it rests against this edge without gaps. Power Supply The K50 requires a supply of 10 – 16V AC or 10 – 28V DC at 100mA. This should be located on an inside wall within the secure area and supplied with 240V 50Hz AC mains. If the K50 is to function during mains failure a 12V DC supply with a battery standby facility should be used. Electric Release This should be fitted according to the manufacturer’s instructions and comply with the relevant statutory regulations. Note that only 12V DC releases can be used if the unit is to operate during main failure. It is strongly recommended that a break glass unit be fitted on installations using fail safe releases. For installations using fail secure releases a mechanical override e.g. internal handle should be fitted. Exit Button This should have normally open contacts and be located within the secure area. Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 7 Installation Cable Colour Code The K50 comes supplied with two meters of twelve-core cable. The following chart gives details of core usage. Cable Colour Red Black Yellow & White Green & Blue Violet & Brown Grey & Turquoise Orange & Pink Usage Power input + ve Power Input - ve Tamper Switch Output Exit Button Input Clean Contact Output (Common) Clean Contact Output (Normally Closed) Clean Contact Output (Normally Open) Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 8 5 8 4 7 9 6 3 ACCES S DE SCRIP T ION INIT IAL ISS 1 DIGITAC 0 2 K50 1 FUNCT ION DAT E NC COM NO EXIT TAMPER EXIT CHE CKED DRAWING No. BPM DRAWN 25 - 4 - 95 DAT E RGD 5006 / 15 APPROVE D INDICATES OPTIONAL WIRING AND EQUIPMENT. EXIT BUTTON MODEL - SE1 ( VARIANTS VSE1 & VFE1 ) TAMPER ALARM OUTPUT NORMALLY CLOSED LOOP MAINS VOLTAGE 230 Vac 50 Hz 12 Vac POWER SUPPLY MODEL - 832/000 TAMPER TAMPER 12Vac 12V 12 V ac 2 0 V A. TITLE INSTALLATION WIRING SCHEMATIC FOR ACCESS CONTROLLER K50 OPERATING FROM AN AC SUPPLY. DOOR RELEASE FAIL SECURE ( LOCKED ) GREEN BLUE ORANGE & PINK Primary 0832/000 Secondary 240 V ac 50/60 Hz. ELVOX Art. JUNCTION BOX MODEL - JB720 GREY & TURQUOISE WHITE VIOLET & BROWN RED BLACK YELLOW THE RAYTEL GROUP LTD. MULTICORE CABLE 2 metres. 25 - 4 - 95 ACCESS CONTROLLER MODEL - K50 ( VARIANTS K50S & K50B ) SECURE AREA Wiring Schematics Wiring Schematics Wiring for K50 using an AC supply with an AC Fail Secure release Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 9 9 5 8 4 7 DE SCRIP T ION INIT IAL ISS 1 DIGITAC 0 6 2 3 ACCE SS 1 K50 FUNCT ION 2 - 5 - 95 DAT E MULTICORE CABLE 2 metres. ACCESS CONTROLLER MODEL - K50 ( VARIANTS K50S & K50B ) RED BLACK YELLOW DOOR RELEASE FAIL SECURE ( LOCKED ) GREEN BLUE ORANGE & PINK - NO EXIT TAMPER TAMPER 12Vdc + 13.8 V L E N EXIT TAMPER EXIT BUTTON MODEL - SE1 ( VARIANTS VSE1 & VFE1 ) TAMPER ALARM OUTPUT NORMALLY CLOSED LOOP 12 V BATTERY ESSENTIAL FOR TIMEZONE OPERATION CHE CKED 2 - 5 - 95 DAT E RGD 5006 / 21 APPROVE D INDICATES OPTIONAL WIRING AND EQUIPMENT. DRAWING No. BPM DRAWN MAINS SUPPLY 230 Vac 50 Hz. INSTALLATION WIRING SCHEMATIC FOR ACCESS CONTROLLER K50 OPERATING FROM A DC SUPPLY. TITLE NC COM JUNCTION BOX MODEL - JB720 GREY & TURQUOISE WHITE THE RAYTEL GROUP LTD. - + TAMP + + BATT OUT POWER SUPPLY UNIT MODEL - 1381LM F 2A VIOLET & BROWN SECURE AREA Wiring Schematics Wiring for K50 using a DC supply and DC Fail Secure release Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 10 9 # 8 0 7 DE SCRIPT IO N INIT IAL ISS 1 DIGITAC 6 5 4 3 2 1 FUNCT IO NA CCE SS K50S ACCESS CONTROLLER MODEL - K50S ( VARIANTS K50 & K50B ) 26 - 4 - 95 DA T E + - TAMP + BATT + OUT DOOR RELEASE FAIL SAFE ( OPENED ) COM NC NO EXIT TAMPER EXIT OPERATING FROM A DC SUPPLY. FOR ACCESS CONTROLLER K50S CHECKE D 26 - 4 - 95 RGD 5006 / 16 AP PRO VE D DA T E ( VARIANTS VSE1 & VFE1 ) MODEL - SE1 EXIT BUTTON TAMPER ALARM OUTPUT NORMALLY CLOSED LOOP 12 V BATTERY ESSENTIAL FOR TIMEZONE OPERATION INDICATES OPTIONAL CABLING AND EQUIPMENT DRAWING No. BPM DRAWN MAINS SUPPLY 230 Vac 50 Hz. TAMPER TAMPER + 12Vdc 13.8 V L E N INSTALLATION WIRING SCHEMATIC TITLE EMERGENCY RELEASE MODEL - BG1 GREEN BLUE ORANGE & PINK GREY & TURQUOISE WHITE VIOLET & BROWN RED BLACK YELLOW JUNCTION BOX MODEL - JB720 POWER SUPPLY UNIT MODEL - 1381LM F 2A THE RAYTEL GROUP LTD. MULTICORE CABLE 2 metres. SECURE AREA Wiring Schematics Wiring for K50 using a DC supply and DC Fail Safe release Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 11 9 8 7 DE S CRIP T ION INIT IAL IS S 1 DIGITAC 0 6 5 4 3 2 K50 ACCESS 1 FUNCTION 29 - 4 - 95 DA T E + - TAMP + + BATT OUT GREEN BLUE ORANGE & PINK TITLE GREY & TURQUOISE WHITE VIOLET & BROWN RED BLACK YELLOW JUNCTION BOX MODEL - JB720 NC COM NO TAMPER EXIT EXIT CHECK E D NC C NO + - TAMPER ALARM OUTPUT NORMALLY CLOSED LOOP 12 V BATTERY ESSENTIAL FOR TIMEZONE OPERATION 29 - 4 - 95 DA T E RGD 5006 / 19 A P P ROV E D INTERFACE BOARD MODEL - PC5006/1 DRAWING No. BPM DRA WN MAINS SUPPLY 230 Vac 50 Hz. TAMPER TAMPER + 12Vdc 13.8 V L E N OPERATION OF A K50 WITH INTERFACE RELAY FOR FAIL SAFE RELEASE. POWER SUPPLY UNIT MODEL - 1381LM DOOR RELEASE FAIL SAFE ( OPENED ) SECURE AREA F 2A THE RAYTEL GROUP LTD. MULTICORE CABLE 2 metres. ACCESS CONTROLLER MODEL - K50 ( VARIANTS K50S & K50B ) IS A FAIL SAFE DEVICE WHICH LOCKS WHEN VOLTS ARE APPLIED. IT IS ESSENTIAL THAT A BATTERY IS USED IN THIS APPLICATION. CIRCUIT AUTOMATICALLY RESETS AS TAMPER LOOP IS RE - ESTABLISHED. THE TYPE OF RELEASE USED IN THIS CIRCUIT TAMPER CLOSED LOOP IS INTERRUPTED. IN THAT THE RELEASE WILL LOCK WHEN THE THE CIRCUIT PROVIDES ADDITIONAL SECURITY NOTE : Wiring Schematics Wiring for K50 Tamper Relay and DC Fail Safe release Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 12 9 8 7 DE SCRIPT ION INIT IAL ISS 1 DIGITAC 0 6 5 4 3 2 K50 A CCES S 1 FUNCT ION ACCESS CONTROLLER MODEL - K50 ( VARIANTS K50S & K50B ) 1 - 5 - 95 DAT E JUNCTION BOX MODEL - JB720 VIOLET & BROWN NC COM - EXIT TAMPER TAMPER 12Vdc NO + 13.8 V EXIT NC + C - CHE CK ED NO DRAWING No. BPM DRA WN MAINS SUPPLY 230 Vac 50 Hz. TAMPER L E N OPERATION OF A K50 WITH INTERFACE RELAY FOR FAIL SECURE RELEASE. TITLE DOOR RELEASE FAIL SECURE ( LOCKED ) GREEN BLUE ORANGE & PINK GREY & TURQUOISE WHITE TAMP + BATT + OUT POWER SUPPLY UNIT MODEL - 1381LM RED BLACK YELLOW SECURE AREA F 2A THE RAYTEL GROUP LTD. CABLE 2 metres. MULTICORE THE CIRCUIT PROVIDES ADDITIONAL SECURITY IN THAT THE RELEASE WILL REMAIN LOCKED WHEN THE TAMPER CLOSED LOOP IS INTERRUPTED. THE TYPE OF RELEASE USED IN THIS CIRCUIT IS A FAIL SECURE DEVICE WHICH UNLOCKS WHEN VOLTS ARE APPLIED. IT IS ESSENTIAL THAT A BATTERY IS USED IN THIS APPLICATION. MOMENTARILY CLOSING THE RESET PUSHBUTTON RESETS THE CIRCUIT AFTER TAMPER LOOP HAS BEEN RE - ESTABLISHED. NOTE : 1 - 5 - 95 DAT E RGD 5006 / 20 APP RO VE D RESET PUSHBUTTON INTERFACE BOARD MODEL - PC5006/1 TAMPER ALARM OUTPUT NORMALLY CLOSED LOOP 12 V BATTERY ESSENTIAL FOR TIMEZONE OPERATION Wiring Schematics Wiring for K50 Tamper Relay and DC Fail Secure release Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 13 1 ISS WIRES CONNECT KEY INITIAL DESCRIPTION PUSH BUTTON WIRES CROSS CALL WIRES CALL PUSH BUTTONS K50 PCB 12 3 4 56 06-01-96 DATE ENTRANCE PANEL MODEL KA1 - KA3 SPEECH UNIT ART 930\832 RED GREY & T URQUOS E G REE N B LUE NO NC COM 12V B LA CK V IO L ET & B RO WN ORA NG E & PINK 240 SYSTEMS LTD. RAYTEL SECURITY 0 PUSH TO OPTIONAL EXIT BUTTON (N\O OUTPUT) EXIT + 15V AC 7 4 B 12 3 56 HANDSET 900/000 7 4 B 12 356 HANDSET 900/000 7 4 B 1 2 35 6 HANDSET 900/000 PI-002-01 CHECKED APPROVED DATE 06-02-96 DRAWING No. DRAWN K.H. INTERFACE RELAY PC5006/1 NO C NC JUNCTION BOX MODEL - JB720 TITLE GENERAL WIRING DIAGRAM FOR KA1-KA3 SYSTEM. WITH AC POWER SUPPLY AND FAIL SECURE RELEASE EXIT EXIT 0V POWER SUPPLY ART 832/000 0 12 12V AC DOOR RELEASE FAIL SECURE (LOCKED) 240V AC 50Hz Wiring Schematics Wiring for KA1-KA3 and AC Fail Secure release Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 14 1 ISS KEY WIRES CONNECT INITIAL DESCRIPT ION PUSH BUTTON WIRES CROSS CALL WIRES CALL PUSH BUTTONS K50 PCB 1 2 3 4 5 6 SPEECH UNIT ART 930\832 27-11-98 DAT E ENTRANCE PANEL MODEL KA1 - KA3 ORANGE & PINK 240 0 RED 0 NO EXIT 12V 0V COM EXIT NC BLACK 12 POWER SUPPLY ART 832/000 15V AC + TITLE GENERAL WIRING DIAGRAM FOR KA1-KA3 SYSTEM. FITTED TO AN ELVOX AUTOMATIC GATE SYSTEM INTERFACE RELAY PC5006/1 NO C NC JUNCTION BOX MODEL - JB720 - 33 12V DC INPUT FROM ELVOX GATE 32 + CONTROL BOX POWER SUPPLY 17 18 TO ELVOX GATE CONTROL BOX. TO INITIATE THE GATE OPEN / CLOSE COMMAND GREY & T URQUOSE GREEN BL UE VIOL ET & BROWN RAYTEL SECURITY SYSTEMS LTD. 240V AC 50Hz CHECKED DRAWING No. K.H. DRAWN DAT E 27 -11 -98 PI-002-01E APPROVED 7 4 B 1 2 3 5 6 HANDSET 900/000 7 4 B 1 2 3 5 6 HANDSET 900/000 7 4 B 1 2 3 5 6 HANDSET 900/000 Wiring Schematics Wiring for KA1-KA3 and Elvox Gate System Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 15 1 IS S WIRES CROSS WIRES CONNECT INITIAL DE S CRIP T IO N PUSH BUTTON CALL WIRES KEY CALL PUSH BUTTONS K50 PCB 1 2 3 4 5 6 SPEECH UNIT ART 930\832 06-01-96 DA T E ENTRANCE PANEL MODEL KA1 - KA3 240 0 O RA NGE & P INK G RE Y & T URQ UO S E G RE EN B L UE EXIT EXIT 0V 240V AC 50Hz 0 NO C NC 12 + 15V AC 0 PUSH TO INTERFACE RELAY PC5006/1 JUNCTION BOX MODEL - JB720 EXIT 240 DC POWER SUPPLY MODEL 1381LM TITLE GENERAL WIRING DIAGRAM FOR KA1-KA3 SYSTEM. WITH DC FAIL SAFE RELEASE OPTIONAL EXIT BUTTON (N\O OUTPUT) NOTE FAIL SAFE LOCKS CONNECT 0V AND NC AS SHOWN FOR USE WITH FAIL SECURE LOCKS CONNECT LOCK TO 0V AND NO NO NC 12V COM B LA CK RE D VIO L ET & BRO WN 0 12V DC DOOR RELEASE FAIL SAFE (UNLOCKED) 12 POWER SUPPLY ART 832/000 RAYTEL SECURITY SYSTEMS LTD. 240V AC 50Hz CHE CKE D DRAWING No. K .H. DRAWN DA T E 0 6 -0 2-9 6 PI-002-02 AP P ROV E D 7 4 B 1 2 3 5 6 HANDSET 900/000 7 4 B 1 2 3 5 6 HANDSET 900/000 7 4 B 1 2 3 5 6 HANDSET 900/000 Wiring Schematics Wiring for KA1 – KA3 with DC Fail Safe release Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 16 A ISS INIT IAL DESCRIPT ION DAT E 22-05-96 CABLE ART 2/063 12V NO NC COM RAYTEL SECURITY SYSTEMS LTD. 12V AC DOOR RELEASE FAIL SECURE (LOCKED) ORANGE & PINK GREY & T URQUOSE GREEN BLUE VIOLET & BROWN BLACK RED EXIT PUSH TO JUNCTION BOX MODEL - JB720 0 NOTE * CONNECT 75-OHM RESISTOR BETWEEN M AND V2 MONITOR ART 5479/01M 0 240V AC 50Hz ENSURE PSU ART 832/030 IS LOCATED AS CLOSE TO THE MONITOR AS POSSIBLE NO NC 12V COM EXIT EXIT 0V CHECKED DRAWING No. K.H. DRAWN PI-007-01 APPROVED PUSH AND INTERFACE RELAY 22-05-96 DAT E 12V DC DOOR RELEASE + JUNCTION BOX MODEL - JB720 FOR FAIL SECURE LOCKS (LOCKED) CONNECT T O NO CONT ACT FOR FAIL SAFE LOCKS (OPEN) CONNECT T O NC CONT ACT FROM EXIT VIOLET & BROWN GREY & T URQUOSE GREEN BLUE ORANGE & PINK RED BLACK VARIANT FOR OPERATION OF DC LOCKS FROM EXTERNAL 12V DC PSU (eg MODEL 138ILM) 240 POWER SUPPLY ART 832/030 12 1 2 RED 3 4 5 6 7 8 9 10 11 12 V1 V2 M* 75 OHM YELLOW FROM K50 GENERAL WIRING DIAGRAM FOR KV1 SYSTEM TITLE OPTIONAL EXIT BUTTON (N\O OUTPUT) EXIT EXIT 0V SUPPLIED CABLE IS FOR RUNS UP TO 30m FOR CABLE RUNS UP TO 100m USE COAXIAL CABLE TYPE RG59 AND CABLE OF 1mm CSA. K50 CABLE 15V AC NO C + NC INTERFACE RELAY PC5006/1 CALL PUSH BUTTON K50 PCB YELLOW RED COAX 7 6 5 4 3 2 1V M CAMERA UNIT 5479/01T ENTRANCE PANEL MODEL KV1 Wiring Schematics Wiring for KV1 System and AC Fail Secure release Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 17 1 ISS INITIAL DESCRIPTION K50 PCB CALL PUSH BUTTONS 3 4 6 7 8 - +TV M CAMERA UNIT 554/H50 ENTRANCE PANEL MODEL KV1 DATE 22-05-96 VIOLET & BROWN GREY & TURQUOSE GREEN BLUE 12V DC DOOR RELEASE FAIL SECURE (LOCKED) ORANGE & PINK NO EXIT PUSH TO NO C NC + 15V AC INTERFACE RELAY PC5006/1 JUNCTION BOX MODEL - JB720 6 7 8 - +T AM15 0 S1 C1 OPTIONAL EXIT BUTTON (N\O OUTPUT) CHECKED DRAWING No. K.H. DRAWN 8 123 569 V MONITOR CABLE RISER GENERAL WIRING DIAGRAM FOR KV5680 1, 2 & 3 KITS TITLE EXIT 15V 0V COM EXIT NC RAYTEL SECURITY SYSTEMS LTD. FOR AC LOCK OPERATION SEE VARIANT FOR DC LOCKS ON DRAWING PI-007-01 K50 CABLE C1C2 1 2 3 - + S BLACK RED M1V1V2 M2 PSU ART 5680 ENSURE A-B SWITCH IS PRI IN THE A POSITION A ENSURE LOCK TIME (P3) IS SET TO MINIMUM B 240V AC V1 M V2 MONITOR ART 5601/000 MONITOR ART 5601/000 21-01-97 DATE RGD 5013 / 65 APPROVED CONNECT 75 OHM RESISTOR TO THE LAST MONITOR BETWEEN TERMINALS V2-M V1 M V2 1 2 3 4 5 6 7 8 9 10 11 12 V1 M V2 1 2 3 4 5 6 7 8 9 10 11 12 Wiring Schematics Wiring for KV1 – KV3 and AC Fail Secure release Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 18 Quick Programming Guide Quick Programming Guide. The K50 is programmed using the keyboard. Entering the six digit Master code accesses the programming mode. The following paragraphs cover initial programming for a basic access control system. To access the more advanced features of the K50 please refer to the Advanced Programming Guide section. Programming a code When the K50 is delivered there are no user codes in memory. The following instructions show how to enter a single user code for standard twenty-four hour operation. Action Indication Notes Enter six Digit Master Code Press the # key Press the # key Red LED lights accompanied by a long audible tone Red LED begins to flash every ½ second Enter a user code Press the # key Press the # key Red LED begins to flash every second Red LED steady, long audible tone, Red LED turns off Found on the inside cover of this manual Master code accepted Ready to accept a user code Code can be four to eight digits in length The code has been accepted Exit function and return to normal operation Ensure that there is less than four seconds delay between each key press. This prevents the Code Entry Timer from registering an invalid code. Deleting a code The following instructions show how to delete a single user code. Action Indication Notes Enter six Digit Master Code Press the # key Press 9 followed by the # key Enter the user code to delete followed by the # key Press the # key Press the * key Red LED lights accompanied by a long audible tone Red LED begins to flash every ½ second Red LED begins to flash every second Two long audible tones Red LED off while tone sounds. Red LED steady, long audible tone, Red LED turns off Found on the inside cover of this manual Master code accepted Delete function entered If the code does not exist the K50 gives a two-second audible tone with steady red LED. The code has been deleted. Note: To escape without deleting the code press the * key instead of the # key. The K50 will give a two-second audible tone with steady red LED. Exit function and return to normal operation Ensure that there is less than four seconds delay between each key press. This prevents the Code Entry Timer from registering an invalid code. Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 19 Quick Programming Guide Setting the Lock Relay Time The lock relay can be set to operate from one to ninety nine seconds when a valid user code is entered or the exit push button is operated. The factory setting for the relay time is four seconds. The following instructions show how to adjust this time if required. Action Indication Notes Enter six Digit Master Code Press the # key Press 1 followed by the # key Enter the required lock time (1 – 99 seconds) followed by the # key Press the # key Press the * key Red LED lights accompanied by a long audible tone Red LED begins to flash every ½ second Relay operates for the number of seconds entered accompanied by the Red LED and Green LED lit and an audible tone Two long audible tones Red LED off while tone sounds. Red LED steady, long audible tone, Red LED turns off Found on the inside cover of this manual Master code accepted Set relay time function entered Should the relay time require adjusting enter the new lock time before proceeding to the next step. This can be repeated as often as required. The lock time has been set Exit function and return to normal operation Ensure that there is less than four seconds delay between each key press. This prevents the Code Entry Timer from registering an invalid code. Activating the K50 self test mode The K50 can test the internal functions and the operation of each button on the keypad by entering the self-test mode. Action Indication Notes Turn off the power to the K50 Hold down the # and * keys Return power to the K50 After the fifth bleep Release the # and * keys The Red and Green LED’s will flash accompanied by an audible bleep. The unit commences the self-test. See K50 test sequence for details of test results. Ensure the # and * keys remain held down Releasing the keys before the fifth bleep exits to normal mode. Releasing the keys between the fifth and ninth bleep enters self-test mode. WARNING: If the keys are not released before the tenth bleep the K50 will enter Master Reset this will clear all the programmed codes. See the Advanced Programming section for details. Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 20 Quick Programming Guide K50 Test sequence After entering Self-test the K50 will run through the following sequence of tests. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. Red LED flashes twice. Green LED flashes twice. Sounder bleeps twice. Lock Relay operates twice. The K50 tests internal functions. Should a fault be detected the test sequence will end and the Red and Green LED’s will flash. If no faults are found the Red and Green LED will illuminate accompanied by a single audible tone. The K50 is now ready to test the keypad. Press each keypad button in turn. Press button 1 both LED’s will flash once accompanied by an audible tone to indicate the button is functioning correctly. Press button 2 both LED’s will flash twice accompanied by an audible tone to indicate the button is functioning correctly. Press buttons 3 to 9 both LED’s will flash, for the number of times corresponding to the button pressed, accompanied by an audible tone to indicate the button is functioning correctly. Press button 0 both LED’s will flash ten times accompanied by an audible tone to indicate the button is functioning correctly. Press button * both LED’s will flash eleven times accompanied by an audible tone to indicate the button is functioning correctly. Press the exit button both LED’s will flash twelve times accompanied by an audible tone to indicate the button is functioning correctly. Press button # both LED’s will give three long flashes accompanied by an audible tone. The unit then returns to normal mode. A self-test can be performed at any time without affecting any programmed settings. Care should be taken however to ensure a Master reset is not performed, as this would clear all pre programmed settings. Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 21 Advanced Programming Guide Advanced Programming Guide. Performing a Master Reset The Master Reset will perform the following tasks: Clear all user codes. Reinstate the Factory master code. Clear all time zone functions and settings Reset sounder operation Reset relay time to four seconds Action Turn off the power to the K50 Hold down the # and * keys Return power to the K50 After the tenth bleep Release the # and * keys Indication Notes The Red and Green LED’s will flash accompanied by an audible bleep. The unit performs a Master Reset. Ensure the # and * keys remain held down Releasing the keys before the fifth bleep exits to normal mode. Releasing the keys between the fifth and ninth bleep enters self-test mode. See previous section for details. Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 22 Advanced Programming Guide Setting the Lock Relay Time The lock relay can be programmed to operate from one to ninety nine seconds when a valid user code is entered or the exit push button is operated. When the K50 is supplied the lock relay time is set at four seconds. To program the Lock Relay Time Action Indication Notes Enter six Digit Found on the inside cover of Master Code this manual Press the # key Red LED lights accompanied by a Master code accepted long audible tone Press 1 followed Red LED begins to flash every ½ Set relay time function entered by the # key second Enter the required Relay operates for the number of Should the relay time require lock time seconds entered accompanied by adjusting enter the new lock (1 – 99 seconds) the Red LED and Green LED lit time before proceeding to the followed by the # and an audible tone next step. This can be key repeated as often as required. Press the # key Two long audible tones Red LED The lock time has been set off while tone sounds. Press the * key Red LED steady, long audible tone, Exit function and return to Red LED turns off normal operation Ensure that there is less than four seconds delay between each key press. This prevents the Code Entry Timer from registering an invalid code. Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 23 Advanced Programming Guide Installing User Codes The K50 can be programmed with a maximum of fifty user codes of four to eight digits in length. These user codes can be programmed to operate in twenty four hour mode, assigned to one of the five timed access periods, service mode or latch mode. User codes assigned to access periods 1 to 5 will not function until the clock and time periods have been set. (See Setting the clock, page 25, and Programming time zones, page 30, for details of how to do this.) User codes assigned to access period 6 are used to enter Service Mode. User codes assigned to access period 7 are used to enter Latch Mode. When the K50 is delivered there are no user codes in memory. Note: If the first four digits of the code being entered is the same as an existing code then the new code will overwrite the existing code. Action Enter six Digit Master Code Press the # key Press 2 followed by the # key Enter the User Code Press the # key Press the # key for 24 hour operation Or For Timed operation press key 1-7 followed by the # key To add additional codes repeat instructions from highlighted section inclusive. OR Press the * key to exit programming mode. To Install Codes Indication Red LED lights accompanied by a long audible tone Red LED begins to flash every ½ second Red LED flashes every second Red LED flashes twice accompanied by a long audible tone Notes Found on the inside cover of this manual Master code accepted Ready to install code Code can be four to eight digits in length The code has been accepted 1 to 5 are timed access periods See Programming time zones, page 30, for details. 6 is service mode, see page 26 for details of use. Red LED steady, long audible tone, Red LED turns off 7 is latch mode, see page 27 for details of use. Exit function and return to normal operation Ensure that there is less than four seconds delay between each key press. This prevents the Code Entry Timer from registering an invalid code. Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 24 Advanced Programming Guide Setting the Clock The clock must be set to enable the time zone facility. (See Programming time zones, page 30 and Installing a user code, page 24 for details of how to set time zones and assign user codes.) When the K50 is delivered the clock is disabled (set to 00hr 00min). After programming, should it be desirable, the clock can be disabled by setting the clock time to 00hr 00min, this has the effect of stopping the clock and disabling all time zone operations. Note: The K50 clock is not battery backed. If time zone operation is to be maintained in the event of mains failure a 12V DC supply with a battery standby facility should be used. If a power failure occurs after the clock has been set, when the power is restored the K50 will bleep three times to indicate the time may require resetting. This will be repeated every minute until the time is reprogrammed or the clock function is disabled by setting the clock time to 00hr 00min. Action Enter six Digit Master Code Press the # key Press 3 followed by the # key Enter the correct time Press the # key Press the # key Press the * key To Set the Time Indication Red LED lights accompanied by a long audible tone Red LED begins to flash every ½ second Red LED flashes every second Red LED flashes twice accompanied by a long audible tone Red LED steady, long audible tone, Red LED turns off Notes Found on the inside cover of this manual Master code accepted Ready to Set the time Time is to be entered using 24hr format. E.g. 9.30 AM would be entered 0930 while 9.30 PM would be entered 2130. The time has been accepted The time has been set Exit function and return to normal operation Ensure that there is less than four seconds delay between each key press. This prevents the Code Entry Timer from registering an invalid code. Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 25 Advanced Programming Guide Setting Service Mode When the K50 is in service mode, pressing any button on the keypad will operate the lock output relay for the pre-set lock time. Service mode can be activated by entering a user code that has been assigned to access period 6 (see Installing a User Code, page 24), manually entered or set to operate automatically by allocating to an access period. When the K50 is delivered, service mode is disabled. Note: Service mode and Latch mode cannot be programmed to the same access period at the same time. When Service or Latch mode is assigned to an access period it overwrites any previously installed mode. Action Enter six Digit Master Code Press the # key Press 4 followed by the # key Press the # key To Enter Service Mode Manually Indication Notes Red LED lights accompanied by a long audible tone Red LED begins to flash every ½ second Red LED flashes off twice accompanied by two long tones and green LED turns on for one second. Found on the inside cover of this manual Master code accepted Ready to enter service mode The K50 exits programming mode and enters Service Mode. To exit Service mode Press and hold the * and # keys together, the red LED will flash accompanied by a short tone, the relay will operate for the pre-set time. The keys should not be released until the relay time ends. Note: This will disable all programmed timed service operations and therefore should not be used to reset a timed operation. Action Enter six Digit Master Code Press the # key Press 4 followed by the # key Enter the access period number (0 – 5) followed by the # key Press the # key Press the * key To Set Service Mode for timed operation Indication Notes Red LED lights accompanied by a long audible tone Red LED begins to flash every ½ second Red LED flashes every second Red LED flashes twice accompanied by a long audible tone Red LED steady, long audible tone, Red LED turns off Found on the inside cover of this manual Master code accepted Ready to enter service mode Service mode has been allocated. Note: access period 0 is used to disable all programmed timed service operations Service mode has been set Exit function and return to normal operation Ensure that there is less than four seconds delay between each key press. This prevents the Code Entry Timer from registering an invalid code. Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 26 Advanced Programming Guide Setting Latch Mode Latch mode is used to latch the lock output relay on. Latch mode can be activated by entering a user code that has been assigned to access period 7 (see Installing a User Code, page 24), manually entered or set to operate automatically by allocating to an access period. When the K50 is delivered latch mode is disabled. Note1: The exit push button is disabled during latch mode operation. Note2: Latch mode and Service mode cannot be programmed to the same access period at the same time. When Latch or Service mode is assigned to an access period it overwrites any previously installed mode. To Enter Latch Mode Manually Action Indication Enter six Digit Master Code Press the # key Press 5 followed by the # key Press the # key Press the * key Red LED lights accompanied by a long audible tone Red LED begins to flash every ½ second Red LED flashes off twice with two long tones and the green LED turns on during relay operation. Red LED steady, long audible tone, Red LED turns off Notes Found on the inside cover of this manual Master code accepted Ready to enter latch mode The K50 exits programming mode and enters latch Mode. Exit function and return to normal operation To exit Latch mode Press the # key or enter a valid user code. Note: Using the # key to exit will disable all programmed timed latch operations and therefore should not be used to reset a timed operation. When a user code is used the sounder and green LED will operate for the pre-set relay time before exiting. To Set Latch Mode for timed operation Action Enter six Digit Master Code Press the # key Press 5 followed by the # key Enter the access period number (0 – 5) followed by the # key Press the # key Press the * key Indication Red LED lights accompanied by a long audible tone Red LED begins to flash every ½ second Red LED flashes every second Red LED flashes twice accompanied by a long audible tone Red LED steady, long audible tone, Red LED turns off Notes Found on the inside cover of this manual Master code accepted Ready to enter latch mode Latch mode has been set. Note: access period 0 is used to disable all programmed timed latch operations Latch mode has been set Exit function and return to normal operation Ensure that there is less than four seconds delay between each key press. This prevents the Code Entry Timer from registering an invalid code. Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 27 Advanced Programming Guide Setting Sounder operation The Sounder is used to give audible indication of key presses and lock relay activation. Should it be required the sounder can be disabled, or, for systems incorporating a long relay activation, the sounder can be programmed with a reduced ON time. When the K50 is delivered the sounder time will equal the relay time and will bleep with each key press. The sounder can be programmed to operate for 1 to 99 seconds during relay operation. Note: The sounder cannot be programmed to operate for longer than the relay time. Action Enter six Digit Master Code Press the # key Press 6 followed by the # key Press the # key to Mute sounder OR The number of seconds required (1 – 99) followed by the # key Press the # key Press the * key To Mute / Set Sounder Indication Red LED lights accompanied by a long audible tone Red LED begins to flash every ½ second Red LED flashes every second Red LED flashes twice accompanied by a long audible tone Red LED steady, long audible tone, Red LED turns off Notes Found on the inside cover of this manual Master code accepted Ready to mute / set sounder The setting has been accepted The time has been set Exit function and return to normal operation Ensure that there is less than four seconds delay between each key press. This prevents the Code Entry Timer from registering an invalid code. Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 28 Advanced Programming Guide Code Capacity Check This function is used to check the number of User Codes programmed into the K50. When initiated the K50 will give a short audible tone for each User Code programmed. Action Enter six Digit Master Code Press the # key Press 7 followed by the # key Press the # key when ready to count. Press the * key Code Capacity Check Indication Red LED lights accompanied by a long audible tone Red LED begins to flash every ½ second Red LED flashes accompanied by a short tone for each User Code programmed in the K50. Red LED flashes twice accompanied by a long audible tone Red LED steady, long audible tone, Red LED turns off Notes Found on the inside cover of this manual Master code accepted Code capacity check entered Each tone indicates one programmed code. Indicates that no more user codes remain to be counted. Exit function and return to normal operation Ensure that there is less than four seconds delay between each key press. This prevents the Code Entry Timer from registering an invalid code. Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 29 Advanced Programming Guide Access Levels and Time Zones Up to two sets of time zone markers (Start1, End1 – Start2, End2) may be programmed into the controller to give a maximum of six separate access levels covering six specific time zones during a 24 hour period. This allows different codes to be assigned to any one of the six time zones. The method for assigning access levels to codes can be found under ”Installing User Codes” on page 24. The following table shows the way in which the time zone markers are used to create the six different access levels. 00.00 hrs Access Level 0 24.00 Start1 No markers Default Setting Level 2 Access Zone 2 active Access Zone 2 active Access Zone 3 active Access Zone 4 active Level 4 Level 5 Markers Start1 – End2 hrs End2 Access Zone 1 active Level 3 Markers Start2 – End2 Start2 Access Zone 0 Active, Unlimited Access Level 1 Markers Start1 – End1 End1 Access Zone 4 active Access Zone 5 active Level 0 does not require any time zone markers to be set and is the default setting for all codes. Codes assigned to this level will have unlimited access during the 24 hour period. (Zone 0). Level 1 is the time zone commencing Start1 and ending with End1, any codes assigned to level 1 will only have access during this period. (Zone 1). Level 2 is the time zone commencing End1 and ending with Start1, any codes assigned to level 2 will only have access during this period. (Zone 2). Level 3 is the time zone commencing Start2 and ending with End2, any codes assigned to level 3 will only have access during this period. (Zone 3). Level 4 is the time zone commencing End2 and ending with Start2, any codes assigned to level 4 will only have access during this period. (Zone 4). is the time zone commencing Start1 and ending with End2, any codes assigned to level 5 will only have access during this period. (Zone 5). Level 5 Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 30 Advanced Programming Guide It should be noted that once time zone markers have been set for one level, they remain fixed in those positions for the other levels. For user codes assigned to access periods to operate correctly the unit clock must be set. Refer to setting the clock, page 25 for details on setting the correct time. By setting time zone markers Start1 and End1, access levels 1 and 2 are available for use. Access levels 3, 4 and 5 will not be available until time zone markers Start2 and End2 have been programmed. Programming Time Zone markers Action Enter six Digit Master Code Press the # key Indication Red LED lights accompanied by a long audible tone Red LED begins to flash every ½ second Red LED flashes every second Notes Found on the inside cover of this manual Master code accepted Press 8 followed Ready to program time zones by the # key Enter time zone 1 Start time has been accepted start time (Start1) in 24 hour format followed by the # key. ( E.g. 0900# for 9 AM) Enter time zone 1 Red LED flashes every 1½ second Stop time has been accepted stop time (End1) in 24 hour format followed by the # key. ( E.g. 1130# for 11.30 AM) Skip the next two operations if time zone 2 is not required Enter time zone 2 Red LED flashes every 2 seconds Start time has been accepted start time (Start2) in 24 hour format followed by the # key. ( E.g. 1600# for 4.00 PM) Enter time zone 2 Red LED flashes every 2½ seconds Stop time has been accepted stop time (End2) in 24 hour format followed by the # key. ( E.g. 1830# for 6.30 PM) Press the # key Red LED flashes twice The time zones have been set accompanied by a long audible tone Press the * key Red LED steady, long audible tone, Exit function and return to Red LED turns off normal operation Ensure that there is less than four seconds delay between each key press. This prevents the Code Entry Timer from registering an invalid code. To deactivate time zones programme the start and stop times to 0000. Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 31 Advanced Programming Guide Deleting a single user code The following instructions show how to delete a single user code. Note: The User Master Code cannot be deleted with this function. Action Enter six Digit Master Code Press the # key Press 9 followed by the # key Enter the user code to delete followed by the # key Press the # key Press the * key Indication Red LED lights accompanied by a long audible tone Red LED begins to flash every ½ second Red LED begins to flash every second Two long audible tones Red LED off while tone sounds. Red LED steady, long audible tone, Red LED turns off Notes Found on the inside cover of this manual Master code accepted Delete function entered If the code does not exist the K50 gives a two-second audible tone with steady red LED. The code has been deleted. Note: To escape without deleting the code press the * key instead of the # key. The K50 will give a two-second audible tone with steady red LED. Exit function and return to normal operation Ensure that there is less than four seconds delay between each key press. This prevents the Code Entry Timer from registering an invalid code. Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 32 Advanced Programming Guide Deleting ALL user codes This function will delete all user codes. All other programmed parameters and the Master Code will not be affected. Action Enter six Digit Master Code Press the # key Press 10 followed by the # key Press the # key Press the * key Indication Red LED lights accompanied by a long audible tone Red LED begins to flash every ½ second Two long audible tones Red LED off while tone sounds. Red LED steady, long audible tone, Red LED turns off Notes Found on the inside cover of this manual Master code accepted Delete function entered Warning: This will delete all programmed user codes. Note: To escape without deleting the code press the * key instead of the # key. The K50 will give a two-second audible tone with steady red LED. Exit function and return to normal operation Ensure that there is less than four seconds delay between each key press. This prevents the Code Entry Timer from registering an invalid code. Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 33 Advanced Programming Guide Changing the Master Code For increased security the Factory Master Code can be reprogrammed to a User Master Code. The User Master Code can be reprogrammed as often as required. Note: A User Master Code cannot be programmed if its first four digits are the same as a current User Code, this also means that a user code cannot be programmed if its first four digits are the same as the current Master Code. Please note there is no function 11. Action Indication Notes Enter six Digit Master Code Press the # key Press 12 followed by the # key Enter the 6 digit Master code followed by the # key. Press the # key Press the * key Red LED lights accompanied by a long audible tone Red LED begins to flash every ½ second Red LED begins to flash every second Two long audible tones Red LED off while tone sounds. Red LED steady, long audible tone, Red LED turns off Found on the inside cover of this manual Master code accepted Ready to reprogram the Master Code The new Master Code has been accepted. The new Master Code has been programmed. Exit function and return to normal operation Ensure that there is less than four seconds delay between each key press. This prevents the Code Entry Timer from registering an invalid code. Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 34 Technical Information Technical Information Power Supply - 10 – 16V AC, 10 – 28V DC. Power Consumption - 9 mA quiescent, 80 mA during relay operation. Lock output - Volt free changeover. Contact rating 50V AC / DC 1.5A inductive. Tamper Switch - Volt free normally open contact. Exit Button - Requires normally open switch input. Code Memory - Permanent retention in E2PROM. Clock Memory - There is no internal battery. The clock will require resetting if power is lost. Power Failure Indication - If the clock has been programmed the K50 will emit three audible bleeps every minute after power is restored. To turn this off set the correct time or disable the clock. Connections - Unit is supplied with two metres of twelve core cable. Visual Indications - Red LED to indicate keypad entry and programming status. Green LED to indicate relay operation. Dust/Water protection - IP54. Dimensions (mm) Model H W D K50 136 80 32 K50 S 146 86 K50 B 146 86 K50 C 146 86 30 K50CB 146 86 30 FB146 (for K50S/B) 135 75 35 SB146/1 (for K50S/B) 151 92 32 KA series (Audio entry panel with keypad) KV series (Video entry panel with keypad) Main Material ABS housing UL 94-5v Stainless Steel grade BS1449/304 Polished Brass grade BS2870/cz120 Stainless Steel grade BS1449/304 Polished Brass grade BS2870/cz120 Zinc Plated Steel, Flush box Coated Steel / Paint finish, Surface box Please contact the office for details Please contact the office for details Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 35 Technical Information Programming Summary Table Steps 1 Description Master code 2 3 4 Function No. 1st Data 5 2nd Data 3rd Data 6 7 8 4th Data Confirm Escape Enter Program Master code # mode Single User Code Master code # # User Code # # AUTO Relay time Master code # 1# Time(seconds)# # * Install Codes (24 hour) Master code # 2# User Code # # * Master code Install Codes # (with time zone) 2# User Code # Set Clock Master code # 3# Time (24Hr) # # * Services Mode Master code # 4# Time Zone # # * Latch Mode Master code # 5# Time Zone # # * Sounder Time Master code # 6# Time(seconds)# # * Code Capacity Master code # 7# # * Time Settings (T1 and T2) Master code # 8# Time 1 # Time 2 # # * Time Settings (T1 to T4) Master code # 8# Time 1 # Time 2 # # * Delete Codes Master code # 9# Code to Delete # # * Delete All User Codes Master code # 10# # * Reprogram Master code Current Master Code # 12# # * New 6 digit Master Code # * Time Zone # Time 3 # Time 4 # Escape Program Mode Southern Office Raytel Security Systems Ltd. Northern Office Tel. 01268 775656 Fax. 01268 745001 Tel. 0141 3324232 Fax. 0141 3326952 36 *