Download to read User Manual & Installation Instructions

Transcript
Install manual
Steam bathroom
MODEL : WS-609P
w w w . e a g l e b a t h. c om
No advanced advice will be submit before we change our design and size.
The pictures may be a little different from the real products.
Our company keep the final explanation right.
Do not dispose this product as unsorted municipal
waste. Collection of such waste separately for special
treatment is necessary.
STEAM CONTROL
Dear Guest,
Thank you very much for purchasing our sanitary ware. To
enable you to use this product safely and effectively, please
read this installation and operation manual carefully before
use.
CAUTIONS
STEAM CONTROL
Self-clean system
Step 2
Step 1
1.Please ensure that the product installed reliable electric leakage
protection device, the power plug contains earth line, and make sure
it is reliable earth line. Check the protect system of leakage
protection each time before use.
2.Do not turn on water pump, heat pump or air bubble pump without
water.
3.Before turn on water pump, check if the water level over jets 10 to
20 mm or not, make sure regular usage of water pump otherwise it
will be destroy because of water leakage.
4.People with Hypertension symptom, after drink or heart disease are
not allowed to use the bathtub. Children have a bath must under
adult's guidance.
5.During use please noticed that don't blocked the jets and avoiding
the air adjustment valve overflowing. Also keep the bathtub clean
and don't let it blocked by hair or mess.
6.During use, please firstly adjust the water temperature or it will be
burned.
7.The bathtub is designed with ergonomic, rise and fall changes are
quite big so during usage pay more attention of be slipped.
8.Please shut down the system when not to use.
TECHNIQUE PARAMETER
Voltage
Ac 1 10 V( ±10%)
Frequency
60H Z
Water
Volatge
0.1~0.2Mpa
Power of
steam
generator
2.65KW
Power of
water pump
1.0HP
Power of
heat pump
1KW
Power of
air pump
Storage
capacity
Storage
capacity
0.2KW
40gall on
0.18m3
CAUTIONS: Heat pump and air bubble pump is optional purchase.
01
WS-609P
Step 3
Pour into cleaning
liquid from here
Step 4
Cleaning method :
1.C lean the steam engine regularly at least once by every 2weeks
or after using 20 times.
2.Inject citric acid as main cleaning liquid,add 1.5L each
time.after 10 minutes, turn on and When the system turns on,
press “
” button to start the steam function for about 30seconds
and then shut down the system.After vent the stagnant
water,repeat 2 or 3 times.
3.CAUTION: The system must be shut down before injecting
WS-609P 16
Packing list
Packing 1
2 p cs b lue c oat ed g las s + 2 pc s f ix ed do or wi th
al um in um po le s a ro un d + 2 pcs m ova bl e doo r +
ST RI PS
Identification of components
C ei l in g + b o tt o m tu b + s t ea m p ip e
Packing 2
Packing 3
3
C on t ro l pa n el c ap ; Sh o we r , W h ee l w it h ca p ,
S ha m po o b o x , Dr a in e r c ap , T - pi l lo w , G la s s
h an d ra i l , d o or H a nd e l , To w el h a nd l e , Se l f
c le a n s y st e m , S c re w s , s oa p bo x
1
2
4
14
5
SCREW (1)
M6x25
16pcs
SCREW (2)
M6x35
8pcs
SCREW (3)
10pcs
SCREW (4)
St4x20
St4x25
SCREW (5)
SCREW (6)
ST4x16
M4x20
4pcs
14pcs
15
16
6
7
8
9
10
11
12
17
18
30pcs
13
1.Top shower
2. Exhaust fan
3.Top light
4.Roof
5.Control panel
15
WS-609P
19
6.Storage shelf
7.Function shift switch
8.Hot/cold water switch
9.Mirror
10.Handle
11.Handrail
12.Left body glass
13.Nozzle
14.Moveable shower
15.Shower chain
16.Elevating holder
17.Soap box
18.Right body glass
19.Room body
WS-609P
02
ATTENTION
22
23
24
25
26
27
30
31
32
33
34
28
29
22.Bathtub
23.Waterfall switch
24.Water jet(6PC)
25.Pillow
26.Nozzle
27.Drainage
28.Drainage switch
29.Marble
INSTALLATION SKETCH
30.Air switch to
open water pump
31.Air adjuster to
strength jets water
32.Steam outlet
33.Recycle net
34.Waterfall
1.In order to be tripped and fell down, pay more attention when get into the
steam room. Please don't shut the finger in the door in order to be hurt.
2.In order to avoid damaging the surface of products please do not use
hardness and sharpness tool to curve the products.
3.In order to course fire, no smoking inside the bathroom.
4.the jets of steam and drainage pipe both are high temperature when
products working, in order to be hurt please be careful.
5.In order to be tripped and fell down please keep clear of the bathtub after
taking shower each time.
6.It will be leaking if the glass glue plastic sheet be off then please add some
more for recover.
7.If there are marks of water please clear with soft cloth and toothpaste.
8.In order to be blocked of drainage device please keep clean of the surface of
bathtub.
9.Please do not hang up heavy things on the steam room or the handle of
steam room.
10.Please deal with the products according to the local laws when it is no
longer be use.
ATTENTION FOR USAGE
1、check if power and cold/hot water switch be turn on or be turn off each time before
use this product.
2、check if power of electronic leakage device be get through or not.
Checking way:
Press testing button, light of power be off, press button of restart then light of
power be on.It is not being what mentioned above after operated step by
step,then that shows the electronic protection device out off control or there is
something wrong with the electronic leakage device,so should ask professional to
check and maintain the product.
3、 Turn off the main power of control panel after stop usage. The plug of power
should be pull out because only turn off all the functions of control panel that is
not stop the power.
4、 People with hypertension or drunk are not allowed to have sauna steam bath.
5、 Children should have sauna steam bath under adult's instruction.
6、 Please don't shut the finger in the door in order to be hurt when get into the
steam room.
1300*1300*2200MM
51.2”*51.2”*86.6”
03 WS-609P
7、 In order to be tripped and fell down, pay more attention when get into the steam
room.
8、 keep clean of the tray in order to be tripped and fell down.
9、Pay attention to the steam sprayer and water tank drainage, they are in high
temperature while working.
WS-609P
14
Notes
Attention:
The machine must be fixed in the circuit which protected
by creepage protectionand should be well-connected with the
ground. Nontechnical people can not be fixed or removed at
random.
1 . Install the steam bathroom in a proper
way and have the electrician or
professional personnel to install the unit ,
the company won ' t take the
responsibility for any improper
installation and usage .
Cold water pipe
Hot water pipe
2.The application of the product shall
observe the operating instructions,
dismantling and alteration without
authorization is prohibited, the
manufacturer shall not take the
responsibility for any problems resulted
from improper use or dismantling by one ' s
self.
Please follow the steps to install the unit.
INSTALLATION PROCESS
Strip A
Strip B
1 . A s se mb l y o f tr a y
i f th e gr o un d i s no t
s mo o th , p l ea s e a d ju st
t he n ai l un de r th e tr a y
t o k e ep t he b al an c e o f
t he t ra y an d gr ou n d .
P le a se ta k e o u t t h e
s te a m p ip e in t hi s st e p .
Drain
St ep 1
13
WS-609P
WS-609P 04
2 . P ls . pu t le ft a nd r ig ht b lu e
c le ar f ix e d g la s s d oo r on a
s of t t a bl e . P ls . pa y at te n ti on
t o t he i r d i re ct i on on t he t ab le
. Do no t pu t th e fi xe d do or o n
h ar d t a bl e , o r th e g l as s w i ll
b e d am a ge d .
S t ep 2
S t ep 3
3 . P ls . lo c k b ot t om
a lu mi n um f ra me & le ft
f ix ed g la s s t og e th er b y
s cr ew s , n e xt lo c k b ot t om
a lu mi n um f ra me & ri gh t
f ix ed g la s s t og e th er i n
t he sa m e w a y . Ne x t , p ls .
l oc k t o p a l um in u m f ra m e
a nd le f t , r ig ht f ix e d
g la ss d oo r to ge t he r . P ls .
p ay at t en t io n t o th e
d et ai l ed p ic tu r e . Af t er
t ha t , p ls . st an d th e ha lf
f in is h ed f ro nt g la ss p an el .
Step 4
Strip A
05
05
WS-609P
M 4× 2 0
M 4× 2 0
4 . I ns t al l st ri p &
m ag ne t ic s tr ip o n l ef t &
r ig ht s id e of th e bl u e
c le ar m ov a bl e g l as s , a ls o
l oc k w h ee l s o n i t s up &
b ot to m si d e . Do n ot
t ig ht e n t h e w he e ls to o
c lo se i n t h is st e p . P ut
t he mo v ab l e d oo r on f ro nt
g la ss p an e l b y p u tt in g
i ts wh e el s on al u mi nu m
r ai ls . Tr y pu sh a nd p ul l
t he mo v ab l e d oo r , a nd
a dj us t it s ti gh t ne ss o f
t he pu l le y to ma k e t h e
d oo r r u n w e ll . F i na ll y ,
t ig ht e n t h e w he e ls of t he
Strip B m ov ab l e d o or & i n st al l
d oo r h a nd l es on m ov ab l e
d oo r .
(1) The electrical pitch
Press
pitch can open the machine, the temperature
is the room temperature.The time will show 30m. At the same
time, it will open the ceiling lamp.Press again will close all the
functions. (After the closure of the machine, the water case
will drainfor 2 minutes)
(2) The application of the back lamp
Press
,the sidelight is on. Press
again, the ceiling
lamp is out, press
a third press, the sidelight is out too.
3) The steam function
Press
,startup the steam function, the water case
will pump water automati-cally. After 60minutes or so, it
will generate steam. (When the water case is lack ofwater,
the controller will replenish automatically)
(4) The air draft function
Under the condition of turnning on, press
can start
up air draft function, pressagain will colse it.
(5) The setting of time or temperature
1. Press
pitch can adjust the time from 1-99.
2. Press
pitch can adjust the temperature from
30-60 .
WS-609P
12
M6 ×35
1
4
2
5
3
6
5 . L o ck le f t & r ig h t
b lu e co at e d g l as s an d
a cr y li c p a ne l to g et he r
b y s c re ws . In s ta l l
s pa r e p ar t s o n th e
b ac k si de b od y , t h ey
a re g la ss h an d ra i l ,
t ow e l h an d ra i l , s oa p
b ox & sh o we r . C ar r y t h e
s te a m r oo m ba c ks i de
b od y to t he t op o f
b ot t om tu b .
St ep 5
7
8
1
Time adjustment pitch+
5
Temperature adjustment pitch-
2
Temperature adjustment pitch+
6
Fan Pitch
3
CeilingLamp/Back Lamp pitch
4
Time adjustment pitch-
11
WS-609P
7
8
8 - ST 4×1 2
6 . P l s . ca r ry t he f ro n t
s id e gl as s bo d y t o th e
t op o f b a th tu b , an d
l oc k sc re w s o n t he
a lu m in um p ol e s f r om
f ix e d d oo r & ba ck s id e
b lu e co at e d g l as s .
T he n th e fr on t &
b ac k si de b od y fi x ed
t og e th er .
Steam Pitch
Main Cock Pitch
S te p 6
WS-609P 06
8 - S T 4×1 2
7 . P e r t he r e ad y s cr e w
h ol e s , pl s . fi x t he
w ho l e s te a m ro o m bo d y on
t he b a t ht u b .
Drawing of water connection
Top shower
Function
shift switch
S t ep 7
Hand shower
Cold/hot
water switch
8 -M 6× 25
3 - S T 4×1 2
8 . P u t t he t o p o n t he
s te a m r oo m b od y, an d
t he n l o ck t h e s c r ew s o n
r ea d y s cr e w ho l es o n t op . .
Water fall
Nozzle
07
WS-609P
Step 8
Steam generator
WS-609P
10
DRAWING OF ELECTRICITY CONNECTION
clean system
steam outlet
water inlet
P ower
OK
9 . Pl s . put gl as s gl ue on f ix ed doo r b ot tom ou tsi de &
in si de and in si de t op par t . .
Control
panel
10 . F in ish ca bl e & w at er p ip e c onn ec ti on . ( p ls . ki nd ly
ch ec k t he a tt ac hed pi ct ure ).
Fa n
L igh t
(AC 12V) ( D C1 2V )
09
WS-609P
WS-609P
08