Download "user manual"

Transcript
Section 3-6
Network Installation
Outdoor Installations
The following example shows how fiber-optic cable can be used to connect a
network between two buildings, eliminating possible adverse affects of lightning.
Node
Node
Noise-prone
environment
Coaxial
cable
Transceiver
Transceiver
Segment 2
Segment 1
Coaxial
cable
Transceiver
Coaxial
cable
Transceiver
Fiber-optic cable Noise-prone
environment
Optical
transceiver
Repeater
Optical
transceiver
Repeater
Note Contact the manufacturer for details on optical fiber devices.
CS1W-FLN12 (10Base-T) Precautions
Precautions on Laying
Twisted-pair Cable
Basic Precautions
• Press the cable connector in firmly until it locks into place at both the hub
and the FL-net (Ver. 2.00) Unit.
• After laying the twisted-pair cable, check the connection with a 10Base-T
cable tester.
Environment Precautions
• The twisted-pair cable for 10Base-T is not shielded, and the hub is
designed for use in OA environments. In environments subject to noise,
we recommend the use of 10Base-5 Ethernet.
• Do not lay the twisted-pair cable together with high-voltage lines.
• Do not lay the twisted-pair cable near devices that generate noise.
• Do not lay the twisted-pair cable in locations subject to high temperatures
or high humidity.
• Do not lay the twisted-pair cable in locations subject to excessive dirt and
dust or to oil mist or other contaminants.
Hub Installation
Precautions
Environment Precautions
• Do not install the hub near devices that generate noise.
• Do not install the hub in locations subject to high temperatures or high
humidity.
• Do not install the hub in locations subject to excessive dirt and dust or to
oil mist or other contaminants.
41