Download M2 Omron servo driver R88D
Transcript
Chapter 4 Application 4-5 ! Periodic Maintenance WARNING ! Caution Do not attempt to disassemble, repair, or modify any Units. Any attempt to do so may result in malfunction, fire, or electric shock. Resume operation only after transferring to the new Unit the contents of the data required for operation. Not doing so may result in an unexpected operation. Servo Motors and Drives contain many components and will operate properly only when each of the individual components is operating properly. Some of the electrical and mechanical components require maintenance depending on application conditions. In order to ensure proper long-term operation of Servo Motors and Drivers, periodic inspection and part replacement is required according to the life of the components. The periodic maintenance cycle depends on the installation environment and application conditions of the Servo Motor or Driver. Recommended maintenance times are listed below for Servo Motors and Drivers. Use these are reference in determining actual maintenance schedules. H Servo Motors · Recommended Periodic Maintenance Oil Seal: 2,000 hours Bearings: 20,000 hours Application Conditions: Ambient motor operating temperature of 40_C, within allowable shaft load, rated operation (rated torque and r/m), installed as described in operation manual. · The radial loads during operation (rotation) on timing pulleys and other components contacting belts is twice the still load. Consult with the belt and pulley manufacturers and adjust designs and system settings so that the allowable shaft load is not exceeded even during operation. If a motor is used under a shaft load exceeding the allowable limit, the motor shaft can break, the bearings can burn out, and other problems can occur. H Servo Driver and Regeneration Units · Recommended Periodic Maintenance Aluminum analytical capacitors: 50,000 hours Application Conditions: Ambient driver (regeneration unit) operating temperature of 55_C, rated operation (rated torque), installed as described in operation manual. · The life of aluminum analytical capacitors is greatly affected by the ambient operating temperature. Generally speaking, an increase of 10_C in the ambient operating temperature will reduce capacitor life by 50%. We recommend that ambient operating temperature be lowered and the power supply time be reduced as much as possible to lengthen the maintenance times for Servo Drivers and Regeneration Units. · It is recommended that the Servo Driver and Regeneration Unit be inspected at five-year intervals if they are used under conditions worse than the above or not used over a long time of time. Contact your OMRON representative for inspection and the necessity of any component replacement. 4-20 4-20