Download D1.2 Document Inspection
Transcript
Is the motor in accordance with Regulation 640/2009 ? (Y/N) Yes Lammers, 13BA-250M-4 B3 3. We obtain the following results using the formulas given in Annex II. of Reg. (EU) 327/2011: For the data at the optimum energy efficiency point see the attached characteristic graph. q (m³/s) pf (Pa) kp Pu (W) 13,3 3250 1 43225 Motor: 13BA-250M-4 B3 (400V,50 Hz) Pnom (kW) cos ϕ I (A) U (V) Pe (W) 55 0,83 92 400 52902 ɳe=Pu / Pe * 100 = 81,7 % ɳtarget = 1,1 * ln(P) - 2,6 + N 10 < P ≤ 500 N = 61 P = 55 (nominal) ɳtarget = 62,8 % ɳe > ɳtarget 81,7 > 62,8 The product meets the requirement of Regulation (EU) 327/2011 Table 1. 69