Download ZMOTION Detection Module Product Specification

Transcript
ZMOTION™ Detection Module
Product Specification
37
Sensitivity
This command controls how sensitive the ZMOTION™ Detection Module is to motion.
Larger values provide lower sensitivity and also have the effect of reducing the range.
Smaller values provide higher sensitivity.
Command: Read Sensitivity 
"s" (0x73)
Description
This command returns the current motion detection sensitivity setting.
Return Values
0 - 255 (decimal)
Normal Command Sequence
“s”
Host
[0 – 255]
ZMOTION
Module
Command: Write Sensitivity 
"S" (0x53)
Description
This command sets the motion detection sensitivity.
Input Values
0 - 255 (decimal)
Normal Command Sequence
“S”
[0–255] Current Value
Host
[0 – 255]
ZMOTION
Module
ACK
PS028405-1010
Serial Commands