Download Warning! - Autic system AS
Transcript
Technical data 2.5.4.4.3 Parameters useful for the PL (EN ISO 138491:2008) and SIL (EN 62061:2005) calculation Note 1 The safety devices (Emergency Stop Push-button, Enebling Device, State Selector) on board of H3 handheld terminal are directly hardware-connected to the output connector pins. For this reason, the numerical values shown in 2.5.4.4.1 and 2.5.4.4.2 consider the highest performances of these devices if used in the conditions described in 2.5.4.4.3. The numerical values of MTTFd, PFHd, SFF and DC were obtained through the assumptions shown in 2.5.4.4.3 and are related to each safety function frequency of use. The values for the overall safety functions of the machine depend on how the output safety signals are managed inside the machine controller. 37