AMP-E8 Series User Manual P/N 821639 Rev-C
Section 1
General Features
and Specifications
Quick Start Guide
Description
Features
Applications
Specifications
Installation
Wohler AMP2-E8 Series
Quick Start Guide
Use the information below to quickly set up your Wohler AMP2-E8 Series product for immediate use. The illustration
below is provided to help you locate and identify the programming buttons described in this quick start guide. See the
sections User Interface Features (page 18) and User Interface Function Guide (page 23) for in-depth instructions and
descriptions of all controls and parameters.
AMP2-E8
Programming Buttons
When in Normal Operational Mode, the software for this family of products allows three fast channel selection modes;
Single, Pair, and Downmix. See above images for button locations. Select channels as follows:
Single Channel Select: Channel selection for the left and right speakers are controlled independently.
Hold down the FN Button, press and release the SINGLE Button. Use the LEFT Button to cycle through the
channels to be assigned to the left speaker channel. Use the RIGHT Button to cycle through the channels to be assigned
to the right speaker channel. Channels are selected for monitoring as they are displayed in the LCD.
Pair Channel Select: Channels are selected in pairs (1/2, 3/4, 5/6, or 7/8) with the first channel in the pair
routed to the left speaker and the second routed to the right speaker.
Hold down the FN Button, press and release the PAIRS Button. Use the RIGHT Button or LEFT Button to cycle
up or down through the channel pairs assigned to the left/right speaker channels. Channels are selected for monitoring as
they are displayed in the LCD.
Downmix Select: Pre-configured downmixes of multi-channel selections may be selected.
Hold down the FN Button, press and release the DOWNMIX Button. Use the RIGHT Button or LEFT Button to
cycle up or down through the downmix selections. Downmixes are selected for monitoring as they are displayed in the