Download Multiserver 3000
Transcript
Marathon 3K Voice/Fax Facility Manual Testing Test Connections Connections for all switched and forceconnected loopback tests are made by modular cable at the rear of the 3K Base Module, as shown in Figure 51. The modular cables for FXO and FXS connections are supplied. The modular cable for E&M connections is available as an option. 3K Base Module RJ11 Optional Modular cable for E&M. Connect terminal block associated with the PBX. RJ1CX E&M RJ1CX Interface Modular cable for FXS or FXO. Connect to telephone set or wall jack. FXS/FXO RJ11 Interface Pin 1 Pin 1 Pin Pin 1 2 3 4 SB M R1 R 5 T 6 T1 7 8 E SG 1 2 R 3 T 4 Figure 5-1. Loopback Connections Loopback Tests, Switching Mode VOICE/FAX TESTS 1. SELF TEST 2. LOOPBACK 3. INPUT LEVEL DISPLAY 4. RESET VOICE/FAX CHANNEL 5. TERMINATE TEST When the voice/fax channel is in the switching mode, the loopback test is single ended. If successful, it verifies that all circuits of the voice/fax channel, including the telephone interface circuits, are working properly. In the following examples all extension numbers are fictitious; the actual extension numbers, if any, are determined by your installation. When the voice/fax channel is force connected to a remote voice/fax channel, both ends are in loopback, and the TM indicator should go on at both ends. 5-4