Current Setting Table
R
R
(If enable function is used)
STEP–
EN–
STEP+
EN+
AMPS/ 0.4
PHASE 0.8
AMPS/ 0.4
PHASE 0.8
1.6
(If enable function is used)
Setting Phase Current
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
1.1
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
1.9
1.6
AMPS/ 0.4
PHASE 0.8
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
AMPS/ 0.4
PHASE 0.8
2.6
0.1
0.2
2.7
Data Sheet: STP-DRV1-DS, 1st Ed, Rev H – (07/2011)
0.1
0.2
3.4
1.6
0.1
0.2
3.5
1.6
The microstepping drive has a built-in feature that will reduce the
motor current by 50% anytime the motor is not moving. Drive
heating is reduced by about 50% and the feature lowers motor
heating by 75%. Slide DIP switch position 4 toward the label marked
“50% Idle” to enable this feature. Please be aware that when this
feature is used, holding torque is reduced.
50% IDLE
50% IDLE
Idle Current Reduction
Selected
(Factory Default)
A+
A–
B+
Cable Color Code
Term Wire Pin #
1
A+
Red
2
A– White
B+ Green 3
B– Black
4
B–
Extension Cable
STP-EXT-020
Stepper Drive
12" Motor Pigtail
with Connector
Step Motor
STP-MTR-xxxxx
Connector
Mounting the Drive
The microstepping drive can be mounted on either the wide or the
narrow side of the chassis using #4 screws. The wide side requires four
screws, while the narrow side requires two screws.
WARNING: Never use the drive in a space where there is no air flow
or the surrounding air temperature is greater than 70 °C.
Wide Side Mount
Narrow Side Mount
Smooth Flat Surface
#4 Screws
Unless you are running at 1 Amp/phase motor current or below,
you may need a heat sink. Often, the metal subpanel being
used for the control system will make an effective heat sink.
Dimensions
1.50
[38.1]
0.125
[3.2]
2.50
[63.5]
4x Ø0.125
[Ø3.2]
2x Ø0.125
[Ø3.2]
3.70
[94.0]
3.75
[95.3]
4.00
[101.6]
Self Test
The microstepping drive includes a self test feature. This feature can
be used for trouble shooting your system. Slide DIP switch position
1 toward the label marked “TEST” and the step motor will slowly
rotate 1/2 revolution forward and then 1/2 revolution backward. This
motion will repeat until the DIP switch is returned to the off position.
The self test will use half step mode and ignore any input signals on
the STEP and DIR terminals. The ENABLE input will continue to
function normally.
TEST
TEST
Self Test OFF
(Factory Default)
Sheet 2 of 2
VDC –
No Current Reduction
Self Test ON
1/2
1/10
1/5
1/2
1.6
1
1/5
1/50
1/10
1/50
1.6
0.1
0.2
3.3
VDC +
+
4
10,000
STEPS/REV
(1/50)
0.1
0.2
1
1/5
1/50
1/10
1/50
1/5
1/50
1/10
1/50
1.8
1.6
4
1/2
1/10
1/5
1/2
STEPS/REV
(1/10)
1/2
1/10
1/5
1/2
2 3
1,000
STEPS/REV
(1/5)
2,000
2 3
Factory
Default
1/5
1/50
1/10
1/50
2 3
STEPS/REV
(HALF)
1/2
1/10
1/5
1/2
2 3
400
AMPS/ 0.4
PHASE 0.8
1.6
0.1
0.2
AMPS/ 0.4
PHASE 0.8
2.5
–
STP-PWR-3204
Idle Current Reduction
Microstepping
The microstepping drive has the ability to be set up for more than just
the normal full and half step resolutions found in other drives. This
ability is referred to as microstepping. It is accomplished by precisely
controlling the amount of current in each phase at each step position
and allows the steps to be electronically subdivided even further. The
drive can be set up for either half step or three microstep resolutions,
1/5, 1/10 or 1/50 microsteps. In a typical 1.8° step motor, this will
equate to 1,000, 2,000 or 10,000 steps per revolution. DIP switch
positions 2 and 3 are used to set the resolution as shown below:
AMPS/ 0.4
PHASE 0.8
STP-DRV-4035
Typical Wiring
Diagram
STPDRV-4035
5 6 7 8 9
5 6 7 8 9
Locate the 9 position DIP switch on the drive.
0.1
The last five positions, 5-9, have a value of
0.2
0.4
current printed adjacent, and are used to set the
0.8
motor phase current. There is always a base
1.6
current of 0.4 A. To add to the base current, slide
the appropriate switches toward their labels marked on the drive’s PC
board.
Example: 2.2 Amps = 0.4 (base current) + 1.6 + 0.2
1.6
0.1
0.2
5 6 7 8 9
Current Setting Formula
0.1
0.2
5 6 7 8 9
Set the drive to the proper motor phase current before applying power
to the drive. The rated current is usually printed on the step motor
label. Setting the DIP switches for the rated current can be achieved
by either following the simple formula that follows below or skipping
to the Current Setting Table shown to the top right and setting the
DIP switch positions to match what is shown in the table for the
current.
1.0
AMPS/ 0.4
PHASE 0.8
1.7
Factory
Default
5 6 7 8 9
0.1
0.2
0.9
AMPS/ 0.4
PHASE 0.8
5 6 7 8 9
R
STEP
5 6 7 8 9
ENABLE
Step Motor
Power Supply
5 6 7 8 9
EN–
STP-DRV-4035
Drive
3.2
5 6 7 8 9
EN+
STEP–
R
2.4
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
5 6 7 8 9
STEP+
DIR+
DIR
1.6
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
3.1
5 6 7 8 9
R
DIR–
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
5 6 7 8 9
STEP
12-24 VDC
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
2.3
5 6 7 8 9
ENABLE
R
STP-DRV-4035
Drive
PLC
with
Sourcing
Outputs
DIR–
DIR
COM
5 6 7 8 9
PLC
with
Sinking
Outputs
+12-24V
DIR+
0.8
–
+
+
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
5 6 7 8 9
–
+12-24V 12 - 24 VDC
COM
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
1.5
5 6 7 8 9
(If enable function is used)
PLC with 12-24 VDC Sink or Source Outputs
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
0.7
5 6 7 8 9
EN+
3.0
5 6 7 8 9
EN–
STEP+
2.9
5 6 7 8 9
R
(If enable function is used)
STEP–
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
2.8
5 6 7 8 9
R
2.2
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
5 6 7 8 9
R
STEP
2.1
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
5 6 7 8 9
ENABLE
2.0
5 6 7 8 9
EN–
5 6 7 8 9
EN+
STEP–
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
5 6 7 8 9
R
STEP+
STP-DRV-4035
Drive
1.4
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
5 6 7 8 9
R
DIR+
1.3
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
5 6 7 8 9
R
STEP
DIR–
DIR
1.2
5 6 7 8 9
ENABLE
COM
Indexer
with
Sourcing
Outputs
STP-DRV-4035
Drive
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
5 6 7 8 9
DIR–
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
0.6
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
5 6 7 8 9
DIR+
DIR
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
0.5
5 6 7 8 9
+12-24V
Indexer
with
Sinking
Outputs
0.4
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
5 6 7 8 9
Indexer with 12-24 VDC Sink or Source Outputs
0.1
0.2
AMPS/ 0.4
PHASE 0.8
1.6
5 6 7 8 9
Some step and direction signals, especially those of some PLCs, do
not use 5 volt logic. In these cases, a signal as high as 24 VDC can be
used with the step motor drive by adding an external dropping
resistor to the STEP, DIR and EN input logic terminals.
For 12 VDC logic, add an 820 Ohm, 1/4 watt resistor
For 24 VDC logic, add an 2200 Ohm, 1/4 watt resistor
Typical Wiring Diagram
Logic Motor
Power Power
5VDC 32 VDC
Using Logic That is Not 5 Volt TTL Level
For a complete user manual, please visit www.automationdirect.com
0.25
[6.4]
0.875
[22.2]
Dimensions = in [mm]
0.15
[3.8]
3.00
[76.2]
0.25
[6.4]