Transcript
Metasys Network Technical Manual 636 Function Modules Section Technical Bulletin Issue Date 0793 Output Triac Electrical Function Module Introduction 3 ● Definition 3 ● Application 4 ● Capabilities 4 ● Theory of Operation 5 ● Specifications 6 Installation Procedures 7 ● General Information 7 ● Lighting Control 7 ● Physical Installation 9 Commissioning Procedures 11 ● Physical Verification 11 ● Software Verification 11 Troubleshooting Procedures © Page 13 ● Troubleshooting Chart 13 ● Ordering Information 15 1993 Johnson Controls, Inc. Order No. 636-057 1 2 Function Module—Output Triac Electrical Function Module Introduction The Output Triac Electrical (OTE) Function Module is an interface between the DCM and field devices. This function module provides increment/decrement control or pulsed control of one of two outputs. The OTE Function Module features: ● three wire increment/decrement control of externally sourced 24 VAC signals ● Auto/Manual (A-M) switch to enable/disable DCM control ● two momentary pushbutton switches (+ and -) for manual intervention ● feedback indication of the Auto/Manual switch setting to the DCM The OTE Function Module plugs into any one of the bottom ten slots associated with the DCM. Figure 1 shows typical function module locations in the NCU. A five slot panel is pictured. Output FMs DCMs I A M O TE 101 ote101 + Definition Figure 1: OTE Function Module Locations Function Module—Output Triac Electrical Function Module 3 Application The OTE Function Module is typically used to control 24 VAC motor driven devices such as the VA-8050 and M25. Capabilities Table 1: OTE Function Module Capabilities Capability Description Purpose Input from DCM DCM inputs a digital command. Allows DCM to provide automatic control of outputs. Auto/Manual Toggle Switch, and Two Momentary Pushbutton Switches Switch selects one of: - Auto—DCM/Triac control of outputs. - Manual—DCM/Triac control disabled. Allows for manual override of DCM control for special situations. Pushbutton switches increment/decrement output in both Auto and Manual modes. Allows for local/manual control, even if the DCM is not present. Power on Reset At low power or after power up, outputs are open circuit. Provides controlled restart. Output to Field Module outputs 3-wire increase/decrease control signal using external 24 VAC output signals. Provides incremental control signals for motor driven actuators. 4 Function Module—Output Triac Electrical Function Module Figure 2 is a function diagram of the Function Module. Theory of Operation OTE (A) A + C o n t ro l E le c tr o n ic s Field Device C OM B 24VAC * I D CM A M (B) ote 101 *2 4 V A C sou rce m a y b e co n tain e d in th e fie ld d e vice o r su pp lie d se pa ra tely. Figure 2: OTE Function Diagram Under DCM control, the process is: ● ● ● The DCM provides control signals to the OTE. The control electronics drive two independent Triacs according to the control signals from the DCM. When energized, each Triac controls externally sourced 24 VAC at up to 2 amps. Manual controls are: ● an Auto/Manual switch (A-M) that can disable the DCM control of the OTE Triacs. The status of this switch is reported back to the DCM at all times. ● a momentary pushbutton (+) that closes the same circuit as Triac A ● a momentary pushbutton (-) that closes the same circuit as Triac B The two pushbuttons operate with the Auto/Manual switch in either position. Function Module—Output Triac Electrical Function Module 5 Specifications Table 2: OTE Function Module Specifications Category Specifications For Configurations Product Code Number FM-OTE101 Output Range Two states (ON/OFF with respect to Common) on each of two leads Output Limits Maximum output current: 2 amps Maximum surge output current: 20 amps for one power cycle, non-repetitive Minimum load current: 70 mA Output voltage drop: 1.6 V Output Protection TRIAC outputs fused at 2.5 amp with slow blow, non-field replaceable fuses Leakage (OFF state) 5 mA Response Time Within one-half of the external 24 VAC supply’s cycle period (Zero crossing detection ensures that Triac turns on at or near zero voltage, and turns off at or near zero current.) Source Power Power is from the PWR in the NCU/NEU. Load requires external Class 2, 24 VAC supply. Operating Environmental Requirements 32 to 122°F (0 to 50°C). 10 to 90% noncondensing RH 86°F (30°C) maximum dew point. Storage/Shipping Environmental Requirements -40 to 158°F (-40 to 70°C). 5 to 95% noncondensing RH 86°F (30°C) maximum dew point. Size 0.85 in. H x 2.6 in. W x 7.0 in. L (2.2 cm H x 6.6 cm W x 17.8 cm L) Weight 0.5 lb. (0.22 kg) Agency Compliance FCC Part 15 Subpart J—Class A, UL 916, CSA C22.2 No. 205 Agency Listings UL Listed and CSA Certified as part of Metasys® 6 Function Module—Output Triac Electrical Function Module Installation Procedures When installing and connecting function modules: General Information ● ● Lighting Control follow NEC and local codes observe maximums as specified in the specification table and in these installation guidelines Figure 3 diagrams the wiring for 24 VAC lighting control applications using the OTE Function Module. TBF W ir e G a u g e a n d Le n g t h Per Local C odes OTE A D CM (A) 1 COM 3 2 - c o il L ig h tin g R e la y + On C o n t ro l E le c tr o n ic s Off 24VAC I B A M 2 (B) C o n n e c tio n to D C M c o m p le te d th ro u g h in te rn a l c o n n e cto r o n e n d o f fu n c tio n m o d u le . T B F in left b a y o f N C U /N E U 3 6 2 5 1 4 T B F in rig h t ba y o f N C U /N E U 1 4 2 5 3 6 Strip wire and insert in side face of TBF. Use set screw in front face to secure. otew ire Figure 3: Wiring for Lighting Relay Application Function Module—Output Triac Electrical Function Module 7 Incremental Control Figure 4 diagrams the wiring for typical incremental control applications using the OTE Function Module. In this example, the field device is a VA-8050 valve. W ir e G a u g e a n d Le n g t h Per Local C odes TBF V A -8 0 5 0 V a lv e OTE A D CM (A) 1 COM 3 Increment* Up Com Dwn + C o n t ro l E le c tr o n ic s 24VAC I B A M 2 (B) C o n n e c tio n to D C M c o m p le te d th ro u g h in te rn a l c o n n e cto r o n e n d o f fu n c tio n m o d u le . T B F in left b a y o f N C U /N E U 3 6 2 5 1 4 Decrement* *Reverse these wires to change valve action. T B F in rig h t ba y o f N C U /N E U 1 4 2 5 3 6 S trip w ire a nd inse rt in sid e fa ce of T B F . U se se t scre w in fro nt face to se cu re. Figure 4: Wiring for Typical Application 8 Function Module—Output Triac Electrical Function Module otew ire Physical Installation Assumptions The following procedure for the physical installation of the Output Triac Electrical (OTE) Function Module assumes: ● Panel (NCU or NEU) is installed. ● Connections to field devices are complete. ● You have engineering drawings defining details for the installation. ● Procedure You are familiar with Metasys Network terminology, and the location and operation of power switches. For each OTE Function Module in the network, perform the following steps. 1. Set the Auto/Manual switch to manual. 2. Refer to the engineering drawings, and identify the proper panel and slot number location for this module. 3. Open latch. 4. Insert the module in the appropriate slot. 5. Close latch, locking function module in place. Function Module—Output Triac Electrical Function Module 9 10 Function Module—Output Triac Electrical Function Module Commissioning Procedures Physical Verification Assumptions Procedure The following procedure for the physical verification of the OTE Function Module assumes: ● Physical installation at the NCU/NEU panel is complete. ● Power is available at the panel power supply, and at the field device. For each OTE Function Module in the network, perform the following steps. 1. Power up the appropriate DCM power supply. 2. Press switch (+) on the OTE. Verify that appropriate field device increments in the appropriate direction as defined in the engineering drawings. 3. Press switch (-) on the OTE. Verify that the field device increments in the opposite direction. Software Verification Assumptions The following procedure for the software verification of the OTE Function Module assumes: ● ● ● Procedure Physical installation at the NCU/NEU panel is complete, including NCM, DCM, FM, etc. The operating software for the network has been downloaded to the NCM controlling the panel. An Operator Workstation is available. For each OTE Function Module in the network, perform the following steps. 1. Select the System summary that includes this OTE object. 2. Set Auto/Manual switch on the OTE to Auto. 3. Adjust the software override command and verify that the object’s Value attribute (as seen in the summary) matches the actual value for the field device. Function Module—Output Triac Electrical Function Module 11 12 Function Module—Output Triac Electrical Function Module Troubleshooting Procedures Troubleshooting Chart Use the diagram in Figure 5 (next page) as a troubleshooting guide. It applies for failures between point objects and field devices connected through an OTE Function Module. Function Module—Output Triac Electrical Function Module 13 Start Is the Summary containing this object displaying correct values? Yes Exit No Is Point object definition OK? No Fix definition. See Operator Workstation User's Manual. Yes Is DCM error LED off and is N2 polling and responding? No Troubleshoot DCM See DCM 101 Technical Bulletin. Yes Is the external power supply OK? No Repair or replace field device if JCI is responsible. Yes Using a DVM, check FM output. Is it OK? No Yes U sing a D V M , che ck in pu t to fie ld de vice. OK? No Replace FM. See Ordering Information ordering information. Refer to Material Return and Allowance Program, Procedure 3C2700 for information on returning defective FMs. for Troubleshoot connections and wiring. Yes Repair or replace field device if JCI is responsible. oteflow Figure 5: OTE Troubleshooting 14 Function Module—Output Triac Electrical Function Module Ordering Information Table 3: Ordering Information Description OTE Function Module Product Code Number FM-OTE101-0 Function Module—Output Triac Electrical Function Module 15 Notes Controls Group 507 E. Michigan Street P.O. Box 423 Milwaukee, WI 53201 16 Function Module—Output Triac Electrical Function Module FAN 636 Metasys Network Technical Manual Revision Date 0793 Printed in U.S.A.