Download FCS SmarTEST ONE Manual

Transcript
SmarTEST X User Manual
STOX-2007-00-00
PID controller
Playback
Pre-trigger time
Pseudo controller
Pseudo monitoring channel
Text book PID controller using any analogue in and output for command
and feedback.
Using the playback feature, the data of a measured data file can serve as a
command signal. RPC III in and output is available as option.
The amount of time, specified in seconds, minutes, or hours that will be
stored before the storage trigger. The pre-trigger time and the recording
time determine the duration of the storage. The recording time is the
amount of time that will be stored after the storage trigger.
A controller that is primarily used to generate intermediate setpoints.
Hence this controller has no direct link to an actuator. It serves as a
setpoint generator of which the output can act as one of the inputs, for the
final command signal calculation, of other control channels.
The pseudo monitoring channel can perform various calculations on
sampled data of the analogue input boards, ranging from addition of the
inputs to table interpolation. The results of these calculations can be
monitored by means of graphics
Q
R
Random waveform file
Rate Limit Active
Reference value
Rest condition
Ring buffers
A.k.a sample data file. A data file of which the points are interconnected by
a straight line to form the command signal of a control channel. The term
random refers to the contents of the data file, which are not known in
advance.
An indicator light on the VGA display of the SmarTEST X indicates if the
rate limiter is active.
In factor control the setpoint is defined as a factor (decimal number) times
a reference value. Often the design load is a convenient choice for the
reference value. Factor control is primarily meant for static testing.
The condition number with tag “rest condition” contains the setpoints to
which the system will make a transition at the end of a shutdown
sequence.
A ring buffer is a time trace of the last N seconds of a certain SCU signal.
By default, every control channel that has an SCU controller has three ring
buffers, force, displacement, and command. In the case of an unexpected
shutdown of the test, these ring buffers can be analyzed to get information
about possible clues that can have caused the shutdown. The pre-trigger –
and post-trigger recording times are user definable.
S
Safety monitoring
Shutdown
Single channel control
Slew rate
The safety monitoring system is an event-action system. The user can
define the conditions, which represent an event, as well as the action,
which should follow the occurrence of this event.
The default method to depressurize a system will be used. If the
application requires that certain subsystems have to be deactivated first,
the user has to do this manually. Selecting shutdown will initiate the
shutdown sequence.
In single channel control one or more control channels can make
transitions from set-point A to set-point B asynchronously. In contrast to
multi channel control, where all control channels will synchronously make
the transitions.
The required time to make the transition from set-point A to set-point B is
automatically calculated by the SmarTEST software. However the user can
influence this calculation by setting certain constraints, one of which is the
slew rate. The slew rate is the maximum gradient at which a change in
force or displacement can be performed. The other constraints are the
group minimum instruction time of a control group and the minimum
Page 165 of 168
All rights reserved. Disclosure to third parties of this document or
STOX-2007-00-00 User Manual v1.8 (iss3_DRAFT).doc
any part thereof, or the use of any information contained therein for
Issue no.:3
Sept 15, 2007
purposes other than provided for this document, is not permitted,
except with prior and express written permission.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com