Download H800 Manual - Afinia 3D Printer
Transcript
Afinia H800 3D Printer User’s Manual Platform Calibration Along with manual leveling the platform, the Afinia software can run a Platform Calibration to adjust the printing of the raft, laying down a level foundation for your model to be printed on. This process is not intended to replace physically leveling the platform, but to work with the leveling. Note: The Platform Calibration will only affect printing when using a raft. If you are printing without a raft, the Calibration is not used. You can calibrate the platform automatically or manually. Automatic Platform Calibration The automatic process will check the height of nine calibration points on the platform. Select Auto Level from the 3D Print menu. The differences in height between the nine calibration points are used to build up the raft to give your model a level foundation on which to print. After the Calibration is complete, the Nozzle Height will be automatically set. To check the calibration values, open the Platform Calibrate option in the 3D Print menu. Calibration values are in the middle section of that window. NOTE: If the Platform Calibrate window doesn’t open (Mac) or any of the values are left empty (PC), the platform is out-of-level by more than 0.9mm at one or more points. You will need to manually level the platform before running the Platform Calibration again (see page 14). 15