Download ANT-5 SDH Access Tester User`s Guide

Transcript
Appendix A – Specifications and ordering information
9.5.6
Defects and Anomalies Injection
All defects and anomalies may be injected
Single, Rate or Continuous injection
LEDs and beeper for audible/visual notification
9.5.7
Overhead Analysis and Injection
The following bytes within SOH and POH may be analysed and injected:
C2, D1, D2, D3, D4, D5, D6, D7, D8, D9, D10, D11, D12, E1, E2, F1, F2, F3, G1, J0,
J1, J2, K1, K2, K3, K4, M1, N1, N2, S1, V5, Z1, Z2.
The following bytes within SOH and POH may be analysed but NOT injected:
A1, A2, B1, B2, B3, H1, H2, H3, H4, Y.
9.5.8
9.6
Performance Analysis
PDH Rates
G.821, G.826, M.2100
SDH STM-n
G.826, G.828, G.829, M.2100, M.2101
SONET
ANSI
Optional Accessories
The range of optional accessories available for the ANT-5 includes a shoulder bag,
neck strap and hard carrying cases. Please contact the nearest JDSU Sales Office or
Technical Assistance Centre for the latest information. For locality information visit our
web site, www.jdsu.com, or contact the nearest Regional Sales Office as listed on
the back of the manual.
9.6.1
Hardware options and order numbers
Option
9.6.2
Order Number
STM-1
1310 SR
4565/00.01
STM-1
1310 SR/1550 LR
4565/00.03
STM-1/-4
1310 SR
4565/91.13
STM-1/-4
1310 SR/1550 LR
4565/00.14
STM-1/-4
1310 LR/1550 LR
4565/91.15
STM-1/-4/-16
1310 LR/1550 LR
4565/91.16
Cables
Balanced E1 Cable RJ-48 / 2xCF
Page 142
ANT-5
K1597