1592015700 User manual iCHILL 200 D GB dP 2 dP 3 dP4 dP5 Pr1 Pr2 Pr3 Parameter CF 1 CF 2 CF 3 CF 4 CF 5 CF 6 CF 7 CF 8 CF 9 CF 10 CF 11 CF 12 CF 13 CF 14 r1.4 23/11/2009 Default read-out of the bottom display 0 Default display read-out configuration top / bottom 0= Configurable 1= Top display: Evaporator IN, Bottom display: Evaporator OUT 0 2= Top display: Condenser IN, Bottom display: Condenser OUT 3=Top display: temperature/Condensing pressure, Bottom Display: evaporating pressure Display read-out of the remote terminals Top display default read-out of the remote terminal_1 0= the read-out depends on the paremeters dP01 – dP02 – dP03 0 1= the read-out shows the NTC probe of the remote panel. Top display default read-out of the remote terminal_2 0= the read-out depends on the paremeters dP01 – dP02 – dP03 0 1= the read-out shows the NTC probe of the remote panel. Password 0 Password 0 Password 0 Configuration Description min Unit Model Type of unit 0= Air / air Chiller 0 1= Air / water Chiller 2= Water / water Chiller Heat pump 0= no 0 1= Yes Not used 0 Compressors Compressors number for circuit 1 1= 1 2= 2 0 3= 3 4= 4 Compressors number for circuit 2 0= 0 1= 1 0 2= 2 3= 3 Number of compressor parzialization 0= none 1= 1 0 2= 2 3= 3 Analog Inputs Pressure or temperature analogue input functioning 0 = Temperature / pressure NTC – 4÷20 mA : The condensing temperature is controlled with NTC probe while for the evaporating pressures of the circuits 1 and 2 and the pressure probe configured as auxiliary output 1 and 2 are controlled with 4÷20mA transducers. 1 = Pressure control with 4÷20 mA: To control the evaporating and condensing pressures it is necessary a 0 4÷20mA transducer. 2 = Temperature / pressure NTC – 0÷5Vdc: The condensing temperature is controlled with NTC probe while for the evaporating pressures of the circuits 1 and 2 and the pressure probe configured as auxiliary output 1 and 2 are controlled with 0÷5Vdc transducers. 3 = Pressure control with 0÷5Vdc: To control the evaporating and condensing pressures it is necessary a ratiometric 0÷5Vdc transducer. PB1 Configuration 0 If configured as digital input o1 PB2 Configuration 0 If configured as digital input o1 PB3 Configuration 0 If configured as digital input o1 PB4 Configuration 0 If configured as digital input o1 PB5 Configuration 0 If configured as digital input o1 PB6 Configuration 0 If configured as digital input o1 PB7 Configuration 0 If configured as digital input o1 17 3 1 1 999 999 999 max 2 1 1 4 3 3 3 25 c63 25 c63 30 c63 30 c63 30 c63 30 c63 25 c63 M. u. Resolution