Download User`s Manual
Transcript
Relative Index Index 12-5 <12. Parameter Lists> Parameter Name Factory Default Write Mode 5 2005 MODE_BLK AUTO AUTO 6 2006 BLOCK_ERR - AUTO 7 8 9 2007 2008 2009 - AUTO AUTO AUTO 10 2010 UPDATE_EVT BLOCK_ALM TRANSDUCER_ DIRECTORY TRANSDUCER_TYPE 65535 AUTO 11 2011 XD_ERROR 0 AUTO 12 2012 13 2013 COLLECTION_ DIRECTORY NOW_DISPLAYING 14 2014 15 AUTO 0 AUTO DISP_TARGET_ FORCE 0 AUTO 2015 NO_OF_VALID_CON 16 2016 VALID_CON_ SUMMARY 17 2017 18 2018 MAO_CON_ SUMMARY ISEL_CON_ SUMMARY 0 (Soft Rev 1.02 AUTO or earlier) 1 (Soft Rev 1.04 or later) 0xFFFF (Soft Rev AUTO 1.02 or earlier) 0x0001 (Soft Rev 1.04 or later) 0x0000 AUTO 19 2019 SIM_CON_ SUMMARY 20 2020 21 2021 BAR_GRAPH_ SELECT EACH_BAR_GRAPH 22 2022 MAIN_TAG_SCROLL 0x0000 (Soft Rev AUTO 1.02 or earlier) 0x0001 (Soft Rev 1.04 or later) 0xFFFF (Soft Rev AUTO 1.02 or earlier) 0xFFFE (Soft Rev 1.04 or later) 0 AUTO 0x0000 AUTO 1 AUTO Explanation A universal parameter that represents block operating condition. It comprises the Actual, Target, Permit and Normal modes. Indicates error status of the PID block. The FVX110 transducer block handles the following factors. Bit 0 = An XD_ERROR has occurred Bit 15 = Target mode is O/S Indicates event information if an event update occurs. Indicates error information if an error occurs in a block. Parameter for storing indexes of FVX110 transducers. Indicates FVX110 types. Indicates 65535 (other) for the FVX110. Stores the most serious errors that occur in the transducer block. 0 = No error 50 = Reset performed 100 = LCD error Stores the DD item ID for the first index of important parameters in the LCD transducer block. Indicates the number that the input currently displayed on the LCD occupies among valid inputs of information. A parameter for identifying information of valid inputs that you want to view 0: Scroll knob is active 1: No.01 in valid connection 2: No.02 in valid connection 3: No.03 in valid connection 4: No.04 in valid connection 5: No.05 in valid connection 6: No.06 in valid connection 7: No.07 in valid connection 8: No.08 in valid connection 9: No.09 in valid connection 10: No.10 in valid connection 11: No.11 in valid connection 12: No.12 in valid connection 13: No.13 in valid connection 14: No.14 in valid connection 15: No.15 in valid connection 16: No.16 in valid connection Indicates how many of the 16 inputs are valid. (Corresponds to the denominator when DISP_PAGE_INFO is displayed.) Sets which of the 16 inputs are valid inputs. Indicates which of the 16 inputs gets MAO block values. Indicates which of the 16 inputs gets IS block values. Indicates which of the 16 inputs gets Simulation state values. Use to specify whether bar graphs should be displayed in the lower field of the LCD. (16 input batch setting) Use to specify whether bar graphs should be displayed in the lower field of the LCD. (Each input batch setting) Use to set the character scroll function for MAIN_TAG information. 0 = scroll function Off 1 = scroll function On IM 01S01C01-01EN