Download Multisizer 4 - Beckman Coulter
Transcript
Configuring Software and Security Customizing the Status Panel NOTE Windows > Status Panel Settings is available only when the software is connected to the Analyzer. 2. In the Concentration Bar pane: a. Select Concentration or Coincidence. If you select Concentration, the particle concentration will appear on the Status Bar. If you select Coincidence, the coincidence correction will appear on the Status Bar. Coincidence correction adjusts for incidences of two particles passing through the aperture at the same time. Based on the size distribution, the Multisizer 4 adjusts the count by replacing large pulses with smaller pulses at a statistically correct size. b. In the Warning Level field, enter the concentration or coincidence correction percentage that will trigger a warning (that is, change the scale color to red or the warning color you select). The default maximum concentration is 10%. For more information on suggested concentration levels, see Preparing the Analyzer for Calibration, page 3-12. c. In the Full Scale field, enter the total concentration percentage that the scale will display. Beckman Coulter recommends that you enter a value that is twice the Warning Level percentage. The default Full Scale percentage is 20%. d. Click ( Color ) to change the scale color used to indicate that the concentration or coincidence correction level is within the acceptable range. 3. In the Jar and Tank Bars pane: a. In the Warning Level box, enter the percent full that will trigger a warning (that is, change the Jar or Waste Tank display to red or the warning color you select). The default warning level is 80%. b. Click ( Color ) to change the color used to display Jar and Waste Tank fluid that is below the warning level. 4. In the Warning Color, Distribution Graph, Progress Bar, Status Text Colors, and Blockage Monitor panes, select the desired Status Bar display options such as lines and colors. 5. In the Click pane: a. In the Every [X] pulses field, enter the number of electrical pulses that will occur between audible clicks on your computer. b. In the Level field, enter a value between 0 and 5 to set the desired volume of the clicks. c. Click ( Test ) to test the volume level. 6. In the Status Panel Location pane, select Left or Right to display the Status Panel on the left or right side of the Multisizer 4 software window. 7. Click ( OK ) when you are finished. Changes take effect immediately. You do not need to restart the Multisizer 4 software. PN A51387AB 8-9 8